Home › Brake › BRAKE SYSTEM (OTHER) › PROPORTIONING VALVE
RM19S0E _54 Brake _051476 BRAKE SYSTEM (OTHER) _0248236 PROPORTIONING VALVE A

BRAKE SYSTEM (OTHER)  PROPORTIONING VALVE  REMOVAL  


PROCEDURE

Hide 1.REMOVE CENTER COWL TOP VENTILATOR LOUVER

C241431

a.

Disengage the 2 clips and slide the hood to cowl top seal as shown in the illustration.


b.
C241408

Disengage the 2 claws and separate the washer hose joint.

NOTICE:

To prevent washer fluid from contaminating the brake master cylinder reservoir, do not separate the washer hose.



c.

Disengage the 2 claws and 6 guides remove the cowl top ventilator louver center.


Hide 2.DRAIN BRAKE FLUID

NOTICE:

Immediately wash off any brake fluid that comes into contact with any painted surfaces.


Hide 74431 4.REMOVE BATTERY TRAY

Hide 74411 5.REMOVE BATTERY CARRIER

A259809

a.

Disengage the 6 wire harness clamps and separate the wire harness from the battery carrier.


b.

Remove the 5 bolts and the battery carrier.


Hide 6.REMOVE PROPORTIONING VALVE

a.
C244473

Using a union nut wrench 10 mm, separate the 6 brake tubes from the proportioning valve and the brake tube way.


b.
C244474

Remove the 2 bolts and the proportioning valve bracket.


c.
C244475

Using a union nut wrench 10 mm, remove the 3 brake tubes from the proportioning valve and the brake tube way.


d.
C244476