This circuit detects the ignition switch ON or off condition, and sends it to the main body ECU.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Main Body / Data List.
According to the display on the intelligent tester, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| IG SW | Ignition switch ON signal /
OFF or ON |
OFF: Ignition switch ACC or off
ON: Ignition switch ON |
- |
Normal conditions listed above are displayed.
OK
NG
for LHD
Disconnect the 3E and 3B instrument panel junction block assembly connectors.
for RHD
Disconnect the 3F and 3B instrument panel junction block assembly connectors.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 3E-1 - Body ground | Always | 11 to 14 V |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 3F-1 - Body ground | Always | 11 to 14 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3B-8 - Body ground | Always | Below 1 Ω |
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector
(to Instrument Panel Junction Block Assembly) |
OK
NG
Reconnect the instrument panel junction block assembly connectors.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 3A-29 - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Component with harness connected
(Instrument Panel Junction Block Assembly) |
OK
NG
Disconnect the 3A instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3A-40 - 3A-54 | Always | Below 1 Ω |
| 3A-40 - Body ground | Always | 10 kΩ or higher |
OK
NG
Replace the main body ECU (See page Power Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL).
NEXT
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Main Body / Data List.
According to the display on the intelligent tester, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| IG SW | Ignition switch ON signal /
OFF or ON |
OFF: Ignition switch ACC or off
ON: Ignition switch ON |
- |
Normal conditions listed above are displayed.
OK
NG