The cooler thermistor (room temperature sensor) for the front seat is installed in the instrument panel to detect the room temperature and control the heater and air conditioner auto mode. The resistance of the room temperature sensor changes in accordance with the front room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the room temperature sensor and reads voltage changes as the resistance of the room temperature sensor changes. This sensor also sends the appropriate signals to the air conditioning amplifier assembly.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1411/11 | An open or short in the cooler thermistor (room temperature sensor) circuit. | ·
Cooler thermistor (room temperature sensor) ·
Harness or connector ·
Air conditioning amplifier assembly |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Data List.
According to the display on the intelligent tester, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Room Temperature Sensor | Room temperature sensor /
Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.1°F) |
Actual room temperature is displayed | - |
The display is as specified in the normal condition column.
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to the DTC) | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| NG | C |
A
B
C
Check for DTCs (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)>DTC CHECK / CLEAR).
DTC B1411/11 is not output
OK
NG
Inspect the cooler thermistor (room temperature sensor) (See page Vehicle Interior>HEATING / AIR CONDITIONING>ROOM TEMPERATURE SENSOR>INSPECTION).
OK
NG
Disconnect the F33 cooler thermistor (room temperature sensor) connector.
Disconnect the F42 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F33-1 - F42-29 (TR) | Always | Below 1 Ω |
| F33-2 - F42-34 (SG-1) | Always | Below 1 Ω |
| F33-1 - Body ground | Always | 10 kΩ or higher |
| F33-2 - Body ground | Always | 10 kΩ or higher |
OK