The combination meter assembly receives information signals from the hazard warning signal switch assembly.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Combination Meter / Data List.
According to the display on the intelligent tester, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Hazard Flasher Switch | Hazard warning signal switch /
OFF or ON |
OFF: Hazard warning signal switch off
ON: Hazard warning signal switch on |
- |
Normal conditions listed above are displayed.
OK
NG
Inspect the hazard warning signal switch assembly (See page Vehicle Exterior>LIGHTING (EXT)>HAZARD WARNING SWITCH>INSPECTION).
OK
NG
| *a | Front view of wire harness connector
(to Combination Meter Assembly) |
Disconnect the F3 combination meter assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F3-1 (B) - Body Ground | Always | 11 to 14 V |
OK
NG
Disconnect the F141 hazard warning signal switch assembly connector.
Disconnect the F3 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F141-1 - F3-3 (HAZ) | Always | Below 1 Ω |
| F141-8 - Body Ground | Always | Below 1 Ω |
| F141-1 - Body ground | Always | 10 kΩ or higher |
OK
NG