DTC P0100 Mass or Volume Air Flow Circuit |
DTC P0102 Mass or Volume Air Flow Circuit Low Input |
DTC P0103 Mass or Volume Air Flow Circuit High Input |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0100 | MAF meter voltage less than 0.2 V, or more than 4.9 V, for 3 seconds (1 trip detection logic: Engine speed less than 4000 rpm) (2 trip detection logic: Engine speed more than 4000 rpm or more) |
|
| P0102 | MAF meter voltage less than 0.2 V for 3 seconds (1 trip detection logic: Engine speed less than 4000 rpm) (2 trip detection logic: Engine speed 4000 rpm or more) |
|
| P0103 | MAF meter voltage more than 4.9 V for 3 seconds (1 trip detection logic: Engine speed less than 4000 rpm) (2 trip detection logic: Engine speed 4000 rpm or more) |
|
| Mass Air Flow Rate (gm/sec) | Malfunction |
| Approximately 0.0 |
|
| 160.0 or more |
|

| 1.READ VALUE USING TECHSTREAM (MAF) |
Connect the Techstream to the DLC3.
Start the engine.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Data List / MAF.
Read the values displayed on the Techstream.
| MAF (gm/sec) | Proceed to |
| 0.0 | A |
| 160.0 or more | B |
| Between 1.0 and 160.0* | C |
|
| ||||
|
| ||||
| A | |
| 2.CHECK TERMINAL VOLTAGE (POWER SOURCE OF MASS AIR FLOW METER) |
![]() |
Disconnect the mass air flow meter connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C26-1 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Front view of wire harness connector (to Mass Air Flow Meter) |
Reconnect the mass air flow meter connector.
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
Disconnect the C26 mass air flow meter connector.
Disconnect the C20 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C26-3 (VG) - C20-118 (VG) | Always | Below 1 Ω |
| C26-2 (E2G) - C20-116 (E2G) |
| Tester Connection | Condition | Specified Condition |
| C26-3 (VG) or C20-118 (VG) - Body ground | Always | 10 kΩ or higher |
Reconnect the mass air flow meter connector.
Reconnect the ECM connector.
|
| ||||
| OK | |
| 4.INSPECT MASS AIR FLOW METER |
Perform On-vehicle Inspection (Click here).
Perform Inspection.
Remove the mass air flow meter (Click here).
Check for foreign matter in the air flow passage of the mass air flow meter.
Inspect the function of the mass air flow meter.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Data List / MAF.
Start the engine.
Check that the mass air flow meter value changes when the engine is raced.
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - EFI RELAY) |
Disconnect the C26 mass air flow meter connector.
Remove the integration relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C26-1 (+B) - 1A-4 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| C26-1 (+B) or 1A-4 - Body ground | Always | 10 kΩ or higher |
Reinstall the integration relay.
Reconnect the mass air flow meter connector.
|
| ||||
| OK | ||
| ||
| 6.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
Disconnect the C26 mass air flow meter connector.
Disconnect the C20 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C26-3 (VG) - C20-118 (VG) | Always | Below 1 Ω |
| C26-2 (E2G) - C20-116 (E2G) |
| Tester Connection | Condition | Specified Condition |
| C26-3 (VG) or C20-118 (VG) - Body ground | Always | 10 kΩ or higher |
Reconnect the mass air flow meter connector.
Reconnect the ECM connector.
|
| ||||
| OK | |
| 7.CHECK HARNESS AND CONNECTOR (SENSOR GROUND) |
Disconnect the C26 mass air flow meter connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C26-2 (E2G) - Body ground | Always | Below 1 Ω |
Reconnect the mass air flow meter connector.
|
| ||||
| OK | ||
| ||