DTC B1815/54 Short in Front Passenger Side Squib 2nd Step Circuit |
DTC B1816/54 Open in Front Passenger Side Squib 2nd Step Circuit |
DTC B1817/54 Short to GND in Front Passenger Side Squib 2nd Step Circuit |
DTC B1818/54 Short to B+ in Front Passenger Side Squib 2nd Step Circuit |
| DTC No. | DTC Detecting Condition | Trouble Area |
| B1815/54 |
|
|
| B1816/54 |
|
|
| B1817/54 |
|
|
| B1818/54 |
|
|

| 1.CHECK FRONT PASSENGER AIRBAG (FRONT PASSENGER SIDE SQUIB 2ND STEP) |
![]() |
Turn the ignition switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the connectors from the front passenger airbag assembly.
Connect the white wire side of SST (resistance 2.1 Ω) to connector E (black connector).
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch on, and wait for at least 60 seconds.
Clear the DTCs stored in the memory (Click here).
Turn the ignition switch off.
Turn the ignition switch on, and wait for at least 60 seconds.
Check the DTCs (Click here).
|
| ||||
| NG | |
| 2.CHECK CONNECTOR |
Turn the ignition switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the SST from connector E.
Check that the instrument panel wire assembly connectors (on the front passenger airbag side) are not damaged.
|
| ||||
| OK | |
| 3.CHECK FRONT PASSENGER SIDE SQUIB 2ND STEP CIRCUIT |
![]() |
Disconnect the connectors from the center airbag sensor assembly.
Check for short to B+ in the circuit.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch on.
Measure the voltage.
| Tester Connection | Switch Condition | Specified Condition |
| Q2-2 (P2+) - Body ground | Ignition switch ON | Below 1 V |
| Q2-1 (P2-) - Body ground | Ignition switch ON | Below 1 V |
Check for open in the circuit.
Turn the ignition switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance.
| Tester Connection | Condition | Specified Condition |
| Q2-2 (P2+) - Q2-1 (P2-) | Always | Below 1 Ω |
Check for short to ground in the circuit.
Measure the resistance.
| Tester Connection | Condition | Specified Condition |
| Q2-2 (P2+) - Body ground | Always | 1 MΩ or higher |
| Q2-1 (P2-) - Body ground | Always | 1 MΩ or higher |
Check for short in the circuit.
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance.
| Tester Connection | Condition | Specified Condition |
| Q2-2 (P2+) - Q2-1 (P2-) | Always | 1 MΩ or higher |
|
| ||||
| OK | |
| 4.CHECK CENTER AIRBAG SENSOR ASSEMBLY |
![]() |
Connect the connectors to the front passenger airbag assembly and the center airbag sensor assembly.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch on, and wait for at least 60 seconds.
Clear the DTCs stored in the memory (Click here).
Turn the ignition switch off.
Turn the ignition switch on, and wait for at least 60 seconds.
Check the DTCs (Click here).
|
| ||||
| OK | ||
| ||
| 5.CHECK INSTRUMENT PANEL WIRE |
![]() |
Check for short to B+ in the circuit.
Restore the released activation prevention mechanism of connector B to the original condition.
Disconnect the instrument panel wire connector from the instrument panel wire assembly.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch on.
Measure the voltage.
| Tester Connection | Switch Condition | Specified Condition |
| DQ1-3 (P2+) - Body ground | Ignition switch ON | Below 1 V |
| DQ1-4 (P2-) - Body ground | Ignition switch ON | Below 1 V |
Check for open in the circuit.
Turn the ignition switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance.
| Tester Connection | Condition | Specified Condition |
| DQ1-3 (P2+) - DQ1-4 (P2-) | Always | Below 1 Ω |
Check for short to ground in the circuit.
Measure the resistance.
| Tester Connection | Condition | Specified Condition |
| DQ1-3 (P2+) - Body ground | Always | 1 MΩ or higher |
| DQ1-4 (P2-) - Body ground | Always | 1 MΩ or higher |
Check for short in the circuit.
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance.
| Tester Connection | Condition | Specified Condition |
| DQ1-3 (P2+) - DQ1-4 (P2-) | Always | 1 MΩ or higher |
|
| ||||
| OK | |
| 6.CHECK INSTRUMENT PANEL WIRE ASSEMBLY |
![]() |
Check for short to B+ in the circuit.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch on.
Measure the voltage.
| Tester Connection | Switch Condition | Specified Condition |
| Q2-2 (P2+) - Body ground | Ignition switch ON | Below 1 V |
| Q2-1 (P2-) - Body ground | Ignition switch ON | Below 1 V |
Check for open in the circuit.
Turn the ignition switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance.
| Tester Connection | Condition | Specified Condition |
| Q2-2 (P2+) - Q2-1 (P2-) | Always | Below 1 Ω |
Check for short to ground in the circuit.
Measure the resistance.
| Tester Connection | Condition | Specified Condition |
| Q2-2 (P2+) - Body ground | Always | 1 MΩ or higher |
| Q2-1 (P2-) - Body ground | Always | 1 MΩ or higher |
Check for short in the circuit.
Release the activation prevention mechanism built into connector D (Click here).
Measure the resistance.
| Tester Connection | Condition | Specified Condition |
| Q2-2 (P2+) - Q2-1 (P2-) | Always | 1 MΩ or higher |
|
| ||||
| OK | ||
| ||