Home › Engine / Hybrid System › 1NZ-FE ENGINE CONTROL › SFI SYSTEM (for Sedan)

SFI SYSTEM (for Sedan) > VC Output Circuit


DESCRIPTION

The ECM constantly generates 5 V power from the battery voltages supplied to the +B (BATT) terminal to operate the microprocessor. The ECM also provides this power to the sensors through the VC output circuit.

A254573E07

When the VC circuit is short-circuited, the microprocessor in the ECM and sensors that are supplied with power through the VC circuit are inactivated because the power is not supplied from the VC circuit. Under this condition, the system does not start up and the MIL does not illuminate even if the system malfunctions.

HINT:
Under normal conditions, the MIL is illuminated for several seconds when the ignition switch is first turned to ON. The MIL goes off when the engine is started.


WIRING DIAGRAM


A254095E02


INSPECTION PROCEDURE

1.CHECK MIL
  1. Check that Malfunction Indicator Lamp (MIL) lights up when turning the ignition switch ON.

    OK:
    MIL lights up



NG
Go to step 2
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

2.CHECK COMMUNICATION BETWEEN TESTER AND ECM
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Check the communication between the Techstream and ECM.

    Result 
    Result
    Proceed To
    Communication is not possible
    A
    Communication is possible
    B



B
GO TO MIL CIRCUIT (Click here)
A


3.CHECK MIL (THROTTLE POSITION SENSOR)
  1. Disconnect the C17 throttle with motor body assembly connector.

  1. Turn the ignition switch to ON.

  1. Check the MIL.

    Result 
    Result
    Proceed To
    MIL does not illuminate
    A
    MIL illuminates
    B

  1. Reconnect the throttle with motor body assembly connector.



B
REPLACE THROTTLE WITH MOTOR BODY ASSEMBLY (Click here)
A


4.CHECK MIL (ACCELERATOR PEDAL POSITION SENSOR)
  1. Disconnect the A20 accelerator pedal assembly connector.

  1. Turn the ignition switch to ON.

  1. Check the MIL.

    Result 
    Result
    Proceed To
    MIL does not illuminate
    A
    MIL illuminates
    B

  1. Reconnect the accelerator pedal assembly connector.



B
REPLACE ACCELERATOR PEDAL ASSEMBLY (Click here)
A


5.CHECK HARNESS AND CONNECTOR (ECM - EACH SENSOR)
  1. Disconnect the C17 throttle with motor body assembly connector.

  1. Disconnect the A20 accelerator pedal assembly connector.

  1. Disconnect the A21 and C20 ECM connectors.

  1. Check the resistance.

    Standard resistance (Check for short):
    Tester Connections
    Specified Conditions
    VCTA (C20-67) - Body ground
    10 kΩ or higher
    VCPA (A21-57) - Body ground
    VCP2 (A21-58) - Body ground

  1. Reconnect the throttle with motor body assembly connector.

  1. Reconnect the accelerator pedal assembly connector.

  1. Reconnect the ECM connectors.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)