| DTC No. | Detection Item | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| C1428 | Motor Circuit Malfunction | With the ABS motor relay OFF, an open in the motor circuit continues for 2 seconds or more. | Brake actuator assembly (Motor circuit) |
Refer to DTCs C146C and C146D.
Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ANTI-LOCK BRAKE SYSTEM>C146C
Inspect the fuses for circuits related to this system before performing the following procedure.
When replacing the skid control ECU (brake actuator assembly), perform reset memory, deceleration sensor zero point calibration and CVT oil pressure calibration (for CVT).
for 1NR-FE
Click hereDrivetrain>K411 CVT>CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM>INITIALIZATION
for 2NR-FE
Click hereDrivetrain>K312 CVT>CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM>INITIALIZATION
Turn the ignition switch off.
Make sure that there is no looseness at the locking part and the connecting part of the connector.
Disconnect the skid control ECU (brake actuator assembly) connector.
| *A | except LHD with Continuously Variable Transaxle |
| *B | for LHD with Continuously Variable Transaxle |
| *a | Front view of wire harness connector
(to Skid Control ECU (Brake Actuator Assembly)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A35-13 (GND2) - Body ground | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A47-13 (GND2) - Body ground | Always | Below 1 Ω |
Reconnect the skid control ECU (brake actuator assembly) connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG