Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) › 2017.10–2018.01
RM30M0E _58 Vehicle Interior _017118 HEATING / AIR CONDITIONING _0086573 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) J

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  Blower Motor Circuit  


DESCRIPTION

The blower motor with fan sub-assembly is operated by signals from the air conditioning amplifier assembly. Blower motor speed signals are transmitted in accordance with changes in the duty ratio.

WIRING DIAGRAM

for TMMIN Made


E272029E11
6.01,0.271 6.167,0.469 0.156,0.198 10 false 1 5.521,0.281 5.677,0.479 0.156,0.198 10 false 2 5.219,0.594 5.51,0.781 0.292,0.188 10 false F53 5.208,0.76 6.583,1.104 1.375,0.344 10 false Blower Motor with Fan Sub-assembly 4.01,0.281 4.167,0.479 0.156,0.198 10 false 3 4.01,0.698 4.167,0.896 0.156,0.198 10 false 1 3.24,0.719 3.396,0.917 0.156,0.198 10 false 2 3.229,0.281 3.385,0.479 0.156,0.198 10 false 5 3.271,1.104 3.604,1.302 0.333,0.198 10 false F78 2.177,0.979 3.135,1.198 0.958,0.219 10 false ECU-IG NO. 1 2.396,0.542 2.729,0.729 0.333,0.188 10 false HTR 0.854,0.385 1.708,0.625 0.854,0.24 10 false from Battery 0.219,0.813 1.667,1.417 1.448,0.604 10 false from Ignition or Starter Switch Assembly*1 or No. 1 Ignition Relay*2 2.042,1.719 2.281,1.917 0.24,0.198 10 false 20 1.708,1.844 1.948,2.042 0.24,0.198 10 false HR 1.604,2.188 1.958,2.375 0.354,0.188 10 false BLW 2.052,2.073 2.313,2.271 0.26,0.198 10 false 22 1.615,2.542 1.969,2.75 0.354,0.208 10 false GND 2.052,2.417 2.313,2.615 0.26,0.198 10 false 14 0.833,2.833 1.083,3 0.25,0.167 10 false F3 0.833,3 2.406,3.396 1.573,0.396 10 false Air Conditioning Amplifier Assembly 0.833,4.313 3.177,4.5 2.344,0.188 10 false *2: w/ Smart Entry and Start System 0.833,3.917 3.167,4.135 2.333,0.219 10 false *1: w/o Smart Entry and Start System 5.125,2.563 5.417,2.76 0.292,0.198 10 false F56 5.115,2.052 5.281,2.271 0.167,0.219 10 false 3 5.115,1.698 5.281,1.917 0.167,0.219 10 false 2 5.313,1.833 5.563,2.042 0.25,0.208 10 false +B 5.323,2.177 5.563,2.396 0.24,0.219 10 false SI 6.115,1.844 6.354,2.052 0.24,0.208 10 false VM 6.438,1.708 6.604,1.927 0.167,0.219 10 false 1 6.031,2.188 6.385,2.406 0.354,0.219 10 false GND 6.448,2.052 6.615,2.271 0.167,0.219 10 false 4 5.125,2.729 6.5,2.948 1.375,0.219 10 false Blower Motor Control 3.271,1.26 4.167,1.479 0.896,0.219 10 false Heater Relay


for TMT Made


E272029E10
6.01,0.271 6.167,0.469 0.156,0.198 10 false 1 5.521,0.281 5.677,0.479 0.156,0.198 10 false 2 5.219,0.594 5.656,0.792 0.438,0.198 10 false F53 5.208,0.76 6.583,1.104 1.375,0.344 10 false Blower Motor with Fan Sub-assembly 4.01,0.281 4.167,0.479 0.156,0.198 10 false 3 4.01,0.698 4.167,0.896 0.156,0.198 10 false 1 3.24,0.719 3.396,0.917 0.156,0.198 10 false 2 3.229,0.281 3.385,0.479 0.156,0.198 10 false 5 2.177,0.979 3.135,1.198 0.958,0.219 10 false ECU-IG NO. 1 3.521,1.125 3.854,1.313 0.333,0.188 10 false HTR 0.854,0.385 1.708,0.625 0.854,0.24 10 false from Battery 0.219,0.813 1.667,1.417 1.448,0.604 10 false from Ignition or Starter Switch Assembly*1 or IG1 Relay*2 2.042,1.719 2.281,1.917 0.24,0.198 10 false 20 1.708,1.844 1.948,2.042 0.24,0.198 10 false HR 1.604,2.188 1.958,2.375 0.354,0.188 10 false BLW 2.052,2.073 2.313,2.271 0.26,0.198 10 false 22 1.615,2.542 1.969,2.75 0.354,0.208 10 false GND 2.052,2.417 2.313,2.615 0.26,0.198 10 false 14 0.833,2.833 1.219,3.031 0.385,0.198 10 false F3 0.833,3 2.406,3.396 1.573,0.396 10 false Air Conditioning Amplifier Assembly 5.125,2.563 5.688,2.854 0.563,0.292 10 false F56 5.115,2.052 5.281,2.271 0.167,0.219 10 false 3 5.115,1.698 5.281,1.917 0.167,0.219 10 false 2 5.313,1.833 5.563,2.042 0.25,0.208 10 false +B 5.323,2.177 5.563,2.396 0.24,0.219 10 false SI 6.115,1.844 6.354,2.052 0.24,0.208 10 false VN 6.438,1.708 6.604,1.927 0.167,0.219 10 false 1 6.031,2.188 6.385,2.406 0.354,0.219 10 false GND 6.448,2.052 6.615,2.271 0.167,0.219 10 false 4 5.125,2.729 6.5,2.948 1.375,0.219 10 false Blower Motor Control 2.396,0.563 2.729,0.75 0.333,0.188 10 false HTR 3.25,3.75 5.917,4.167 2.667,0.417 10 false *1: w/o Smart Entry and Start System 3.25,4.083 6,4.5 2.75,0.417 10 false *1: w/o Smart Entry and Start System


CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following procedure.


PROCEDURE

1.CHECK VEHICLE TYPE
a.

Check vehicle type.


Result:
Result Proceed to
for TMMIN Made A
for TMT Made B



A

2.PERFORM ACTIVE TEST USING GTS

B

13.PERFORM ACTIVE TEST USING GTS (BLOWER MOTOR)
2.PERFORM ACTIVE TEST USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

According to the display on the GTS, perform the Active Test.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Blower Motor Blower motor with fan sub-assembly Min.: 0
Max.: 31
-
Body Electrical > Air Conditioner > Active Test
Tester Display
Blower Motor
50004 121 2

Result:
Result Proceed to
NG (Blower motor with fan sub-assembly does not operate) A
NG (Blower motor with fan sub-assembly operates but does not change speed) B
OK C



A

3.INSPECT HEATER RELAY

B

11.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (BLW SIGNAL)

C

3.INSPECT HEATER RELAY
a.

Remove the heater relay.



Result:
Proceed to
OK
NG



OK

4.INSPECT BLOWER MOTOR WITH FAN SUB-ASSEMBLY

NG

REPLACE HEATER RELAY

4.INSPECT BLOWER MOTOR WITH FAN SUB-ASSEMBLY
a.

Remove the blower motor with fan sub-assembly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>FRONT BLOWER MOTOR(for TMMIN Made)>REMOVAL


b.

Inspect the blower motor with fan sub-assembly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>FRONT BLOWER MOTOR(for TMMIN Made)>INSPECTION


Result:
Proceed to
OK
NG



OK

5.CHECK HARNESS AND CONNECTOR (HEATER RELAY - POWER SOURCE)

NG

5.CHECK HARNESS AND CONNECTOR (HEATER RELAY - POWER SOURCE)
a.
E281479C03
0.333,0.771 0.76,1.01 0.427,0.24 0.427,0.781 0.885,0.979 0.458,0.198 10 false F78 0.125,0.125 0.583,0.323 0.458,0.198 10 false *1
*1 Heater Relay Holder


Remove the heater relay.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
F78-2 - Body ground Ignition switch off Below 1 V
F78-2 - Body ground Ignition switch ON 11 to 14 V
F78-5 - Body ground Always 11 to 14 V



Result:
Proceed to
OK
NG



OK

6.CHECK HARNESS AND CONNECTOR (HEATER RELAY - BLOWER MOTOR WITH FAN SUB-ASSEMBLY AND BLOWER MOTOR CONTROL)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK HARNESS AND CONNECTOR (HEATER RELAY - BLOWER MOTOR WITH FAN SUB-ASSEMBLY AND BLOWER MOTOR CONTROL)
a.

Remove the heater relay.


b.

Disconnect the F53 blower motor with fan sub-assembly connector.


c.

Disconnect the F56 blower motor control connector.


d.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
F78-3 - F53-2 Always Below 1 Ω
F78-3 - F56-2 (+B) Always Below 1 Ω
F78-3 or F53-2 - Body ground Always 10 kΩ or higher
F78-3 or F56-2 (+B) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

7.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR CONTROL - BLOWER MOTOR WITH FAN SUB-ASSEMBLY AND BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR CONTROL - BLOWER MOTOR WITH FAN SUB-ASSEMBLY AND BODY GROUND)
a.

Disconnect the F56 blower motor control connector.


b.

Disconnect the F53 blower motor with fan sub-assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
F56-1 (VM) - F53-1 Always Below 1 Ω
F56-4 (GND) - Body ground Always Below 1 Ω
F56-1 (VM) or F53-1 - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

8.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - HEATER RELAY AND BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

8.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - HEATER RELAY AND BODY GROUND)
a.

Disconnect the F3 air conditioning amplifier assembly connector.


b.

Remove the heater relay.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
F3-20 (HR) - F78-1 Always Below 1 Ω
F3-14 (GND) - Body ground Always Below 1 Ω
F3-20 (HR) or F78-1 - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

9.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BLOWER MOTOR CONTROL)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

9.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BLOWER MOTOR CONTROL)
a.

Disconnect the F3 air conditioning amplifier assembly connector.


b.

Disconnect the F56 blower motor control connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
F3-22 (BLW) - F56-3 (SI) Always Below 1 Ω
F3-22 (BLW) or F56-3 (SI) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

10.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (HR SIGNAL)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

10.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (HR SIGNAL)
E182281C14
1.167,0.125 1.563,0.354 0.396,0.229 0.563,1.01 0.427,1.76 true 0.333,1.792 0.646,1.958 0.313,0.167 10 false HR 1.271,0.156 1.573,0.333 0.302,0.177 10 false F3 0.104,0.01 0.323,0.188 0.219,0.177 10 false *a
*a Component with harness connected (Air Conditioning Amplifier Assembly)


a.

b.

Reconnect the air conditioning amplifier assembly connector.


c.

Reconnect the F53 blower motor with fan sub-assembly connector.


d.

Reconnect the F56 blower motor control connector.


e.

Reinstall the heater blower motor relay.


f.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
F3-20 (HR) - Body ground Ignition switch ON Blower switch off 11 to 14 V
F3-20 (HR) - Body ground Ignition switch ON Blower switch LO Below 1 V



Result:
Proceed to
OK
NG



OK

11.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (BLW SIGNAL)

NG

11.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (BLW SIGNAL)
a.

b.

Reconnect the air conditioning amplifier assembly connector.


c.

Turn the ignition switch to ON.


d.

Turn the blower switch on (LO).


e.
E219641E02
1.115,0.333 1.604,0.625 0.49,0.292 2.052,1.344 2.26,2.292 true 1.281,0.406 1.542,0.583 0.26,0.177 10 false F3 0.073,0.052 0.24,0.208 0.167,0.156 10 false *a 2.302,2.198 2.625,2.365 0.323,0.167 10 false BLW 2.854,3.979 3.198,4.125 0.344,0.146 10 false GND

Measure the waveform between terminal F3-22 (BLW) of the air conditioning amplifier assembly and body ground.

OK:

Waveform is similar to that shown in the illustration.


HINT:

The waveform varies with the blower speed.


Item Content
Tool setting 1 V/DIV., 50 μs./DIV.
Vehicle condition Ignition switch ON
Blower switch: LO


Result:
Proceed to
OK
NG



OK

12.REPLACE BLOWER MOTOR CONTROL

NG

12.REPLACE BLOWER MOTOR CONTROL

b.

Operate the blower motor with fan sub-assembly to check that it function properly.

OK:

Blower motor with fan sub-assembly operates normally.



Result:
Proceed to
OK
NG



OK

END (BLOWER MOTOR CONTROL WAS DEFECTIVE)

NG

13.PERFORM ACTIVE TEST USING GTS (BLOWER MOTOR)
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

According to the display on the GTS, perform the Active Test.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Blower Motor Blower motor with fan sub-assembly Min.: 0, Max.: 31 -
Body Electrical > Air Conditioner > Active Test
Tester Display
Blower Motor
50004 121 2

Result:
Result Proceed to
OK A
NG (Blower motor with fan sub-assembly does not operate) B
NG (Blower motor with fan sub-assembly operates but does not change speed) C



A

B

14.INSPECT HTR RELAY

C

22.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (BLW SIGNAL)
14.INSPECT HTR RELAY
a.

Remove the HTR relay from the No. 3 relay block.



Result:
Proceed to
OK
NG



OK

15.INSPECT BLOWER MOTOR WITH FAN SUB-ASSEMBLY

NG

REPLACE HTR RELAY

15.INSPECT BLOWER MOTOR WITH FAN SUB-ASSEMBLY
a.

Remove the blower motor with fan sub-assembly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>FRONT BLOWER MOTOR(for TMT Made)>REMOVAL


b.

Inspect the blower motor with fan sub-assembly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>FRONT BLOWER MOTOR(for TMT Made)>INSPECTION


Result:
Proceed to
OK
NG



OK

16.CHECK HARNESS AND CONNECTOR (HTR RELAY - POWER SOURCE)

NG

16.CHECK HARNESS AND CONNECTOR (HTR RELAY - POWER SOURCE)
a.

Remove the HTR relay from the No. 3 relay block.


b.
E371818C01
0.115,0.167 0.427,0.323 0.313,0.156 10 false *1 1.625,0.354 1.938,0.51 0.313,0.156 10 false *a
*1 No. 3 Relay Block
*a HTR Relay Holder


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
Relay terminal 2 - Body ground Ignition switch off Below 1 V
Ignition switch ON 11 to 14 V
Relay terminal 5 - Body ground Always 11 to 14 V



Result:
Proceed to
OK
NG



OK

17.CHECK HARNESS AND CONNECTOR (HEATER RELAY - BLOWER MOTOR WITH FAN SUB-ASSEMBLY AND BLOWER MOTOR CONTROL)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

17.CHECK HARNESS AND CONNECTOR (HEATER RELAY - BLOWER MOTOR WITH FAN SUB-ASSEMBLY AND BLOWER MOTOR CONTROL)
a.

Remove the HTR relay from the No. 3 relay block.


b.

Disconnect the F53 blower motor with fan sub-assembly connector.


c.

Disconnect the F56 blower motor control connector.


d.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Relay terminal 3 - F53-2 Always Below 1 Ω
Relay terminal 3 - F56-2 (+B) Always Below 1 Ω
Relay terminal 3 - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

18.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR CONTROL - BLOWER MOTOR WITH FAN SUB-ASSEMBLY AND BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

18.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR CONTROL - BLOWER MOTOR WITH FAN SUB-ASSEMBLY AND BODY GROUND)
a.

Disconnect the F53 blower motor with fan sub-assembly connector.


b.

Disconnect the F56 blower motor control connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
F56-1 (VN) - F53-1 Always Below 1 Ω
F56-4 (GND) - Body ground Always Below 1 Ω
F56-1 (VN) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

19.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - HEATER RELAY AND BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

19.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - HEATER RELAY AND BODY GROUND)
a.

Disconnect the F3 air conditioning amplifier assembly connector.


b.

Remove the HTR relay from the No. 3 relay block.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
F3-20 (HR) - Relay Terminal 1 Always Below 1 Ω
F3-14 (GND) - Body ground Always Below 1 Ω
F3-20 (HR) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

20.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BLOWER MOTOR CONTROL)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

20.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BLOWER MOTOR CONTROL)
a.

Disconnect the F3 air conditioning amplifier assembly connector.


b.

Disconnect the F56 blower motor control connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
F3-22 (BLW) - F56-3 (SI) Always Below 1 Ω
F3-22 (BLW) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

21.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (HR SIGNAL)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

21.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (HR SIGNAL)
a.

b.

Reconnect the F3 and z2 air conditioning amplifier assembly connectors.


c.

Reconnect the blower motor with fan sub-assembly connector.


d.

Reconnect the blower motor control connector.


e.

Reinstall the heater blower motor relay.


f.
E182281C51
1.167,0.083 1.667,0.333 0.5,0.25 0.563,1.01 0.427,1.76 true 0.333,1.792 0.646,1.958 0.313,0.167 10 false HR 0.104,0.01 0.323,0.188 0.219,0.177 10 false *a 1.313,0.135 1.667,0.313 0.354,0.177 10 false F3
*a Component with harness connected (Air Conditioning Amplifier Assembly)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
F3-20 (HR) - Body ground Ignition switch ON Blower switch off 11 to 14 V
F3-20 (HR) - Body ground Ignition switch ON Blower switch LO Below 1 V



Result:
Proceed to
OK
NG



OK

22.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (BLW SIGNAL)

NG

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

22.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (BLW SIGNAL)
a.

b.

Reconnect the F3 and z2 air conditioning amplifier assembly connectors.


c.

Turn the ignition switch to ON.


d.

Turn the blower switch on (LO).


e.
E219641C06
1.01,0.333 1.5,0.583 0.49,0.25 2.333,0.333 2.823,0.583 0.49,0.25 2.052,1.344 2.26,2.292 true 2.5,0.375 2.844,0.583 0.344,0.208 10 false z2 0.073,0.052 0.24,0.208 0.167,0.156 10 false *a 2.302,2.198 2.625,2.365 0.323,0.167 10 false BLW 2.854,3.979 3.198,4.125 0.344,0.146 10 false GND 1.167,0.385 1.51,0.594 0.344,0.208 10 false F3
*a Component with harness connected
(Air Conditioning Amplifier Assembly)


Measure the waveform between terminal F3-22 (BLW) of the air conditioning amplifier assembly and body ground.

OK:

Waveform is similar to that shown in the illustration.


HINT:

The waveform varies with the blower speed.


Item Content
Tool setting 1 V/DIV., 50 μs./DIV.
Vehicle condition Ignition switch ON
Blower switch: LO


Result:
Proceed to
OK
NG



OK

23.REPLACE BLOWER MOTOR CONTROL

NG

23.REPLACE BLOWER MOTOR CONTROL

b.

Operate the blower motor with fan sub-assembly to check that it function properly.

OK:

Blower motor with fan sub-assembly operates normally.



Result:
Proceed to
OK
NG



OK

END (BLOWER MOTOR CONTROL WAS DEFECTIVE)

NG