When an impact is detected, a relay inside the door control battery is operated to switch the power source of the door lock with motor assemblies from the vehicle battery to the door control battery.
Inspect the fuses for circuits related to this system before performing the following procedure.
As the door control battery is installed between the vehicle battery and body computer, first perform the inspections to confirm that there are no malfunctions in the power source circuit for the body computer before performing this troubleshooting procedure.
Click hereVehicle Interior>DOOR LOCK>POWER DOOR LOCK CONTROL SYSTEM>PRECAUTION
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
When disconnecting the cable from the negative (-) battery terminal while performing repairs, some systems need to be initialized after the cable is reconnected.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION
If the airbag sensor assembly is replaced, refer to the Airbag System.
Click hereVehicle Interior>SUPPLEMENTAL RESTRAINT SYSTEMS>AIRBAG SYSTEM>PRECAUTION
Check the power door lock basic functions.
Click hereVehicle Interior>DOOR LOCK>POWER DOOR LOCK CONTROL SYSTEM>OPERATION CHECK
All doors lock and unlock normally.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the door control battery.
Click hereVehicle Interior>DOOR LOCK>DOOR CONTROL BATTERY>REMOVAL
Inspect the door control battery.
Click hereVehicle Interior>DOOR LOCK>DOOR CONTROL BATTERY>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F125 body computer connector.
Disconnect the F183 door control battery connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F183-9 (ACTG) - F125-1 (ACTG) | Always | Below 1 Ω |
| F183-9 (ACTG) or F125-1 (ACTG) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F183 door control battery connector.
Disconnect the 6L driver side junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F183-8 (IG) - 6L-6 | Always | Below 1 Ω |
| F183-8 (IG) or 6L-6 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the driver side junction block assembly.
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL
| *a | Component without harness connected
(Driver Side Junction Block Assembly) |
- | - |
Remove the body computer from the driver side junction block assembly.
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 6L-6 - MB-7 (IG) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the door control battery connector.
| *a | Rear view of wire harness connector
(to Door Control Battery) |
Measure the voltage according to the value(s) in the table below.
After the ignition switch is turned off, the door control battery is discharged in at most 30 minutes. The discharge time may be shortened depending on the amount of door control battery charge.
After the ignition switch is turned ON, the door control battery is charged in at most 90 seconds. The charging time may be shortened depending on the amount of door control battery charge.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F183-9 (ACTG) - Body ground | Door control battery not charged | Below 2 V |
| Door control battery charging or charged | 7.3 to 9.9 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) battery terminal.
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.
Turning the ignition switch to ON with the airbag ECU assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Disconnect the airbag ECU assembly connector.
Click hereVehicle Interior>SUPPLEMENTAL RESTRAINT SYSTEMS>AIRBAG SYSTEM>PRECAUTION
Connect the cable to the negative (-) battery terminal.
| *a | Rear view of wire harness connector
(to Airbag ECU Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| F21-18 (GSW) - Body ground | Ignition switch ON | 2.8 to 4.3 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) battery terminal.
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.
Turning the ignition switch to ON with the airbag ECU assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Disconnect the 6I driver side junction block assembly connector.
Disconnect the F21 airbag ECU assembly connector.
Vehicle Interior>SUPPLEMENTAL RESTRAINT SYSTEMS>AIRBAG SYSTEM>PRECAUTION
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 6I-2 - F21-18 (GSW) | Always | Below 1 Ω |
| 6I-2 or F21-18 (GSW) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the driver side junction block assembly.
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL
| *a | Component without harness connected
(Driver Side Junction Block Assembly) |
- | - |
Remove the body computer from the driver side junction block assembly.
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| MB-22 (GSW) - 6I-2 | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG