MALFUNCTION DESCRIPTION
These DTCs are stored when the generator temperature sensor output is abnormal. The cause of this malfunction may be one of the following:
Generator temperature sensor internal malfunction
Open or short in generator temperature sensor
The connectors are not connected properly
Foreign matter or water on the connector terminals
Open or short in wire harness
If any of these DTCs are stored, the generator temperature sensor is malfunctioning and the self-protection function may not operate. Therefore under certain high load driving condition, the temperature of the generator (MG1) becomes high. If the self-protection function does not operate, the generator (MG1) may malfunction and cause the vehicle to enter fail-safe mode.
Refer to the description for DTC P0A3611.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A3611
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0A361C | Generator Temperature Sensor Voltage Out of Range | After a long soak, the value of the generator (MG1) temperature sensor is different from the value of the other temperature sensors.
(2 trip detection logic) |
·
Wire harness or connector ·
Generator temperature sensor (Hybrid vehicle transaxle assembly) |
Comes on | Master Warning: Comes on |
| P0A361F | Generator Temperature Sensor Circuit Intermittent | Sudden change in generator temperature sensor output or hunting:
Unusual sudden change in generator temperature sensor output occurs and offset condition continues for a certain period of time, or unusual change in motor temperature sensor output occurs repeatedly. (1 trip detection logic) |
·
Wire harness or connector ·
Generator temperature sensor (Hybrid vehicle transaxle assembly) |
Comes on | Master Warning: Comes on |
| DTC No. | Data List |
|---|---|
| P0A361C | ·
Generator Temperature ·
Motor Temperature ·
Inverter Coolant Water Temperature |
| P0A361F | Generator Temperature |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off.
Leave the vehicle as is for 5 hours or more and then check the values of the Data List items "Generator Temperature", "Motor Temperature" and "Inverter Coolant Water Temperature".
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
With ignition switch ON and wait for 5 seconds or more.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Refer to the wiring diagram for DTC P0A3611.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A3611
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| No DTCs in the table below are output | A |
| Any of the DTCs in the table below are output | B |
| Relevant DTC | |
|---|---|
| P261029 | ECM/PCM Engine Off Timer Performance Signal Invalid |
Post-procedure1
Turn the ignition switch off.
A
B
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| No DTCs in the table below are output | A |
| Any of the DTCs in the table below are output | B |
| Relevant DTC | |
|---|---|
| P0A3611 | Generator Temperature Sensor Circuit Short to Ground |
| P0A3615 | Generator Temperature Sensor Circuit Short to Auxiliary Battery or Open |
Post-procedure1
Turn the ignition switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A2A11
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector) | C |
A
B
C
Pre-procedure1
Disconnect the A68 hybrid vehicle control ECU connector.
Procedure1
| *a | Front view of wire harness connector
(to Hybrid Vehicle Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A68-45 (GMT) - A68-46 (GMTG) | Ignition switch off | 0.3338 to 1487 kΩ |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the A68 hybrid vehicle control ECU connector.
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A3611
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector) | C |
A
B
C
Pre-procedure1
Disconnect the DA2 No. 1 engine room relay block and No. 1 junction block assembly connector.
Disconnect the A68 hybrid vehicle control ECU connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
When performing the measurement, lightly jiggle the wire harness up and down and left and right and confirm that the resistance does not fluctuate.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| DA2-9 (GMT) - A68-45 (GMT) | Ignition switch off | Below 1 Ω |
| DA2-8 (GMTG) - A68-46 (GMTG) | Ignition switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| DA2-9 (GMT) or A68-45 (GMT) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| DA2-8 (GMTG) or A68-46 (GMTG) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the A68 hybrid vehicle control ECU connector.
Reconnect the DA2 No. 1 engine room relay block and No. 1 junction block assembly connector.
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A3611
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector) | C |
A
B
C
Pre-procedure1
Disconnect the D59 generator temperature sensor connector.
Disconnect the DA2 No. 1 engine room relay block and No. 1 junction block assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
When performing the measurement, lightly jiggle the wire harness up and down and left and right and confirm that the resistance does not fluctuate.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| DA2-9 (GMT) - D59-5 (GMT) | Ignition switch off | Below 1 Ω |
| DA2-8 (GMTG) - D59-4 (GMTG) | Ignition switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| DA2-9 (GMT) or D59-5 (GMT) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| DA2-8 (GMTG) or D59-4 (GMTG) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the DA2 No. 1 engine room relay block and No. 1 junction block assembly connector.
Reconnect the D59 generator temperature sensor connector.
OK
NG
Pre-procedure1
Disconnect the DA2 No. 1 engine room relay block and No. 1 junction block assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| DA2-9 (GMT) - DA2-8 (GMTG) | Ignition switch off | 0.3338 to 1487 kΩ |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the DA2 No. 1 engine room relay block and No. 1 junction block assembly connector.
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A3611
| Proceed to |
|---|
| OK |
| NG |
OK
NG