Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM
RM36W0E _51 Engine / Hybrid System _087936 HYBRID / BATTERY CONTROL _0420051 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0A361C  Generator Temperature Sensor Voltage Out of Range  P0A361F  Generator Temperature Sensor Circuit Intermittent  


DTC SUMMARY

MALFUNCTION DESCRIPTION


These DTCs are stored when the generator temperature sensor output is abnormal. The cause of this malfunction may be one of the following:

Generator temperature sensor malfunction
·

Generator temperature sensor internal malfunction

·

Open or short in generator temperature sensor


Wire harness between the generator temperature sensor and hybrid vehicle control ECU
·

The connectors are not connected properly

·

Foreign matter or water on the connector terminals

·

Open or short in wire harness


HINT:

If any of these DTCs are stored, the generator temperature sensor is malfunctioning and the self-protection function may not operate. Therefore under certain high load driving condition, the temperature of the generator (MG1) becomes high. If the self-protection function does not operate, the generator (MG1) may malfunction and cause the vehicle to enter fail-safe mode.



DESCRIPTION

Refer to the description for DTC P0A3611.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A3611

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0A361C Generator Temperature Sensor Voltage Out of Range After a long soak, the value of the generator (MG1) temperature sensor is different from the value of the other temperature sensors.
(2 trip detection logic)
·

Wire harness or connector

·

Generator temperature sensor (Hybrid vehicle transaxle assembly)


Comes on Master Warning: Comes on
P0A361F Generator Temperature Sensor Circuit Intermittent Sudden change in generator temperature sensor output or hunting:
Unusual sudden change in generator temperature sensor output occurs and offset condition continues for a certain period of time, or unusual change in motor temperature sensor output occurs repeatedly.
(1 trip detection logic)
·

Wire harness or connector

·

Generator temperature sensor (Hybrid vehicle transaxle assembly)


Comes on Master Warning: Comes on

Related Data List
DTC No. Data List
P0A361C
·

Generator Temperature

·

Motor Temperature

·

Inverter Coolant Water Temperature


P0A361F Generator Temperature

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY


DTC P0A361C
1.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

2.

Turn the ignition switch off.

3.

Leave the vehicle as is for 5 hours or more and then check the values of the Data List items "Generator Temperature", "Motor Temperature" and "Inverter Coolant Water Temperature".

4.

Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.

5.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




DTC P0A361F
1.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

2.

Turn the ignition switch off and wait for 2 minutes or more.

3.

With ignition switch ON and wait for 5 seconds or more.

4.

Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.

5.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




WIRING DIAGRAM

Refer to the wiring diagram for DTC P0A3611.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A3611

PROCEDURE

1.CHECK DTC OUTPUT (ENGINE)

Pre-procedure1

a.

None.


Procedure1

b.

Check for DTCs.

Powertrain > Engine > Trouble Codes
50001 372
Result:
Result Proceed to
No DTCs in the table below are output A
Any of the DTCs in the table below are output B


Relevant DTC
P261029 ECM/PCM Engine Off Timer Performance Signal Invalid


Post-procedure1

c.

Turn the ignition switch off.



A

2.CHECK DTC OUTPUT (HYBRID CONTROL)

B

2.CHECK DTC OUTPUT (HYBRID CONTROL)

Pre-procedure1

a.

None.


Procedure1

b.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Result:
Result Proceed to
No DTCs in the table below are output A
Any of the DTCs in the table below are output B


Relevant DTC
P0A3611 Generator Temperature Sensor Circuit Short to Ground
P0A3615 Generator Temperature Sensor Circuit Short to Auxiliary Battery or Open


Post-procedure1

c.

Turn the ignition switch off.



A

3.CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR)

B

GO TO DTC CHART (SFI SYSTEM)

3.CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A2A11

Result:
Result Proceed to
OK A
NG (The connector is not connected securely) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector) C



A

4.CHECK HARNESS AND CONNECTOR (GENERATOR TEMPERATURE SENSOR - HYBRID VEHICLE CONTROL ECU)

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK HARNESS AND CONNECTOR (GENERATOR TEMPERATURE SENSOR - HYBRID VEHICLE CONTROL ECU)

Pre-procedure1

a.

Disconnect the A68 hybrid vehicle control ECU connector.


Procedure1

b.
A460761C02
1.469,0.156 1.906,0.448 0.438,0.292 2.313,1.563 2.5,1.885 true 2.156,1.552 2.01,1.896 true 0.125,0.104 0.438,0.26 0.313,0.156 10 false *a 1.563,0.219 1.938,0.427 0.375,0.208 10 false A68 2.396,1.927 2.896,2.115 0.5,0.188 10 false GMTG 1.865,1.927 2.365,2.115 0.5,0.188 10 false GMT
*a Front view of wire harness connector
(to Hybrid Vehicle Control ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A68-45 (GMT) - A68-46 (GMTG) Ignition switch off 0.3338 to 1487 kΩ


Result:
Proceed to
OK
NG



Post-procedure1

c.

Reconnect the A68 hybrid vehicle control ECU connector.



OK

5.CHECK CONNECTOR CONNECTION CONDITION (INTERMEDIATE CONNECTOR)

NG

9.INSPECT HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR TEMPERATURE SENSOR)
5.CHECK CONNECTOR CONNECTION CONDITION (INTERMEDIATE CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A3611

Result:
Result Proceed to
OK A
NG (The connector is not connected securely) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector) C



A

6.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - NO. 1 ENGINE ROOM RELAY BLOCK AND NO. 1 JUNCTION BLOCK ASSEMBLY)

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - NO. 1 ENGINE ROOM RELAY BLOCK AND NO. 1 JUNCTION BLOCK ASSEMBLY)

Pre-procedure1

a.

Disconnect the DA2 No. 1 engine room relay block and No. 1 junction block assembly connector.


b.

Disconnect the A68 hybrid vehicle control ECU connector.


Procedure1

c.

Measure the resistance according to the value(s) in the table below.

HINT:

When performing the measurement, lightly jiggle the wire harness up and down and left and right and confirm that the resistance does not fluctuate.


Standard Resistance (Check for Open):
Tester Connection Condition Specified Condition
DA2-9 (GMT) - A68-45 (GMT) Ignition switch off Below 1 Ω
DA2-8 (GMTG) - A68-46 (GMTG) Ignition switch off Below 1 Ω


Standard Resistance (Check for Short):
Tester Connection Condition Specified Condition
DA2-9 (GMT) or A68-45 (GMT) - Body ground and other terminals Ignition switch off 10 kΩ or higher
DA2-8 (GMTG) or A68-46 (GMTG) - Body ground and other terminals Ignition switch off 10 kΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

d.

Reconnect the A68 hybrid vehicle control ECU connector.


e.

Reconnect the DA2 No. 1 engine room relay block and No. 1 junction block assembly connector.



OK

7.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR TEMPERATURE SENSOR CONNECTOR)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR TEMPERATURE SENSOR CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A3611

Result:
Result Proceed to
OK A
NG (The connector is not connected securely) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector) C



A

8.CHECK HARNESS AND CONNECTOR (NO. 1 ENGINE ROOM RELAY BLOCK AND NO. 1 JUNCTION BLOCK ASSEMBLY - GENERATOR TEMPERATURE SENSOR)

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

8.CHECK HARNESS AND CONNECTOR (NO. 1 ENGINE ROOM RELAY BLOCK AND NO. 1 JUNCTION BLOCK ASSEMBLY - GENERATOR TEMPERATURE SENSOR)

Pre-procedure1

a.

Disconnect the D59 generator temperature sensor connector.


b.

Disconnect the DA2 No. 1 engine room relay block and No. 1 junction block assembly connector.


Procedure1

c.

Measure the resistance according to the value(s) in the table below.

HINT:

When performing the measurement, lightly jiggle the wire harness up and down and left and right and confirm that the resistance does not fluctuate.


Standard Resistance (Check for Open):
Tester Connection Condition Specified Condition
DA2-9 (GMT) - D59-5 (GMT) Ignition switch off Below 1 Ω
DA2-8 (GMTG) - D59-4 (GMTG) Ignition switch off Below 1 Ω


Standard Resistance (Check for Short):
Tester Connection Condition Specified Condition
DA2-9 (GMT) or D59-5 (GMT) - Body ground and other terminals Ignition switch off 10 kΩ or higher
DA2-8 (GMTG) or D59-4 (GMTG) - Body ground and other terminals Ignition switch off 10 kΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

d.

Reconnect the DA2 No. 1 engine room relay block and No. 1 junction block assembly connector.


e.

Reconnect the D59 generator temperature sensor connector.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

9.INSPECT HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR TEMPERATURE SENSOR)

Pre-procedure1

a.

Disconnect the DA2 No. 1 engine room relay block and No. 1 junction block assembly connector.


Procedure1

b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
DA2-9 (GMT) - DA2-8 (GMTG) Ignition switch off 0.3338 to 1487 kΩ


Result:
Proceed to
OK
NG



Post-procedure1

c.

Reconnect the DA2 No. 1 engine room relay block and No. 1 junction block assembly connector.



OK

REPAIR OR REPLACE HARNESS OR CONNECTOR (HYBRID VEHICLE CONTROL ECU - NO. 1 ENGINE ROOM RELAY BLOCK AND NO. 1 JUNCTION BLOCK ASSEMBLY)

NG

10.INSPECT HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR TEMPERATURE SENSOR)
10.INSPECT HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR TEMPERATURE SENSOR)

OK

REPAIR OR REPLACE HARNESS OR CONNECTOR (NO. 1 ENGINE ROOM RELAY BLOCK AND NO. 1 JUNCTION BLOCK ASSEMBLY - GENERATOR TEMPERATURE SENSOR)

NG