Refer to the description for P0D2D16.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>P0D2D16
The MG ECU, which is built into in the inverter with converter assembly, controls motor (MG2) based on commands from the hybrid vehicle control ECU. The MG ECU monitors communication data and detects malfunctions.
The hybrid vehicle control ECU monitors communication data and detects malfunctions.
A communication error between the MG ECU and the hybrid vehicle control ECU.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P312387 | Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message | Error in reception from inverter with converter assembly (MG ECU) via serial communication (out of communication standard)
(1 trip detection logic) |
·
Wire harness or connector ·
Inverter with converter assembly ·
Hybrid vehicle control ECU ·
PCU FR fuse |
Comes on | Master Warning: Comes on |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
With ignition switch ON and wait for 2 minutes or more.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Refer to the wiring diagram for the inverter low-voltage circuit.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Inverter Low-voltage Circuit
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Pre-procedure1
Remove the PCU FR fuse from the No. 5 relay block assembly.
Procedure1
| *1 | No. 5 Relay Block Assembly |
| *2 | PCU FR Fuse |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| PCU FR fuse | Always | Below 1 Ω |
Post-procedure1
Install the PCU FR fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P06881F
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
Turn the ignition switch to ON and wait for 2 minutes or more.
Procedure1
Check Diagnosis Related Information.
| Tester Display |
|---|
| Diagnosis Related Information |
| Result | Proceed to |
|---|---|
| Diagnosis Related Information P312387 is output | A |
| Diagnosis Related Information P312387 is not output | B |
Post-procedure1
Turn the ignition switch off.
A
B
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P312387 is output | A |
| P312387 is not output | B |
Post-procedure1
Turn the ignition switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P056014
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>P033500
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A56 inverter with converter assembly connector.
Procedure1
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A56-24 (GND1) - Body ground | Ignition switch off | Below 1 Ω |
| A56-23 (GND2) - Body ground | Ignition switch off | Below 1 Ω |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A56-6 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| A56-5 (+B2) - Body ground | Ignition switch ON | 11 to 14 V |
Turning the ignition switch to ON with the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Post-procedure1
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the A56 inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A56 inverter with converter assembly connector.
Disconnect the A68 hybrid vehicle control ECU connector.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Procedure1
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector
(to Hybrid Vehicle Control ECU) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A68-2 (HMCL) - Body ground | Ignition switch ON | Below 1 V |
| A68-13 (HMCH) - Body ground | Ignition switch ON | Below 1 V |
Turning the ignition switch to ON with the hybrid vehicle control ECU connector and the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A56-19 (HMCL) - A68-2 (HMCL) | Ignition switch off | Below 1 Ω |
| A56-20 (HMCH) - A68-13 (HMCH) | Ignition switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A56-19 (HMCL) or A68-2 (HMCL) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A56-20 (HMCH) or A68-13 (HMCH) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
As there might be an intermittent malfunction, inspect the following items even if the measured resistance is as specified.
Check that each connector between the inverter with converter assembly and hybrid vehicle control ECU is not loose or disconnected.
Post-procedure1
Reconnect the A68 hybrid vehicle control ECU connector.
Reconnect the A56 inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A56 inverter with converter assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *a | Component with harness connected
(Hybrid Vehicle Control ECU) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A68-2 (HMCL) - A68-13 (HMCH) | Ignition switch off | 110 to 130 Ω |
Post-procedure1
Reconnect the A56 inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
| *1 | No. 5 Relay Block Assembly |
| *2 | PCU FR Fuse |
Replace the PCU FR fuse.
Turn the ignition switch to ON (READY).
Procedure1
Check if there is an open circuit in the PCU FR fuse in the No. 5 relay block assembly.
There is no open circuit in the PCU FR fuse.
If the fuse does not become open again after turning the ignition switch to ON (READY), it can be assumed that the previous fuse failed due to age.
Post-procedure1
Turn the ignition switch off.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the PCU FR fuse from the No. 5 relay block assembly.
Disconnect the A56 inverter with converter assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *1 | No. 5 Relay Block Assembly | *2 | PCU FR Fuse Holder |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A56-6 (+B), A56-5 (+B2) or 2 (PCU FR fuse holder) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
Post-procedure1
Reconnect the A56 inverter with converter assembly connector.
Install the PCU FR fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT