Auxiliary battery power is supplied to the AM terminal of the battery ECU assembly in order to store DTCs and freeze frame data. Even if the ignition switch is turned off, back-up power is supplied.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P056014 | System Voltage (BATT) Circuit Short to Ground or Open | Malfunction in the battery ECU assembly back-up power source circuit
(1 trip detection logic) |
·
Wire harness or connector ·
Battery ECU assembly ·
Fuse |
Comes on | Master Warning:
Comes on |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON and wait for 5 seconds or more.
Enter the following menus: Powertrain / HV Battery / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Pre-procedure1
| *1 | Power Distribution Box Assembly |
| *2 | ECU-B NO. 1 Fuse |
Remove the ECU-B NO. 1 fuse from the power distribution box assembly.
Procedure1
Check if there is an open circuit in the ECU-B NO. 1 fuse in the power distribution box assembly.
There is no open circuit in the ECU-B NO. 1 fuse.
Post-procedure1
Install the ECU-B NO. 1 fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 HV battery hose.
Procedure1
Check the connector connections and contact pressure of the relevant terminals for the battery ECU assembly.
The connectors are connected securely and there are no contact pressure problems.
Post-procedure1
Install the No. 1 HV battery hose.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 HV battery hose.
Disconnect the z12 battery ECU assembly connector.
Connect the cable to the negative (-) auxiliary battery terminal.
Procedure1
| *a | Front view of wire harness connector
(to Battery ECU Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z12-12 (AM) - z12-34 (GND) | Ignition switch off | 11 to 14 V |
Turning the ignition switch to ON with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
If the ignition switch is turned to ON with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
As there might be an intermittent malfunction in the battery ECU assembly power source circuit, inspect the following even if the measured voltage is as specified.
Installation condition of fuse(s) (before removing fuse(s)) (Power Source Circuit)
Fuse condition (before and after removing fuse(s)) (Power Source Circuit)
Connection condition of connectors (Power Source Circuit)
Wire harness condition (Power Source Circuit)
Wire harness condition (GND circuit)
Post-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the z12 battery ECU assembly connector.
Install the No. 1 HV battery hose.
| Proceed to |
|---|
| OK |
| NG |
OK