The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during the semiconductor power integration ECU removal/installation are shown below.
When the cable is disconnected / reconnected to the auxiliary battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.
Learning completes when vehicle is operated normally
1. PRECAUTION
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
2.DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL
for Gasoline Model:
Click hereGeneral>MAINTENANCE>M15A-FKS AUXILIARY BATTERY>REMOVAL
for HV Model:
Click hereGeneral>MAINTENANCE>M15A-FXE AUXILIARY BATTERY>REMOVAL
82662A
3.REMOVE NO. 1 RELAY BLOCK COVER
Disengage the claws to remove the No. 1 relay block cover.
82644
4.REMOVE SEMICONDUCTOR POWER INTEGRATION ECU
Make sure the connector terminal is free from oil and grease.
Do not subject the semiconductor power integration ECU to any impact.
Do not use a semiconductor power integration ECU that has been dropped.
Do not disassemble the semiconductor power integration ECU.
Disengage the claws and pull up the semiconductor power integration ECU.
| *a | power source connector |
Disconnect the power source connector.
Disengage the claw and pull up the lock lever to disconnect the connector as shown in the illustration.