These DTCs are stored when communication between the radio and display receiver assembly and combination meter assembly or headup display (meter mirror sub-assembly)* is not possible.
*: w/ Headup Display System
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| B1324 | Lost Communication with Meter | CAN reception error | ·
Local bus communication line ·
Combination meter power source circuit ·
Combination meter assembly ·
Radio and display receiver assembly ·
Harness or connector ·
No. 4 global can junction connector |
| B1325 | Lost Communication with HUD | CAN reception error | ·
Local bus communication line ·
Headup display (meter mirror sub-assembly) power source circuit ·
Headup display (meter mirror sub-assembly) ·
Radio and display receiver assembly ·
Harness or connector ·
No. 4 global can junction connector |
The radio and display receiver assembly is the master unit.
Inspect the fuses for circuits related to this system before performing the following procedure.
Check for DTCs and check that no DTCs are output.
| Result | Proceed to |
|---|---|
| DTC B1324 and B1325 are not output | A |
| DTC B1324 and B1325 are output | B |
| DTC B1324 is output | C |
| DTC B1325 is output | D |
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B
C
D
Disconnect the cable from the negative (-) auxiliary battery terminal.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H115-10 - H115-21 | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (Below 54 Ω) | B |
| NG (70 Ω or higher) | C |
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B
C
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the H115 No. 4 global can junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H115-10 - H115-21 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the H115 No. 4 global can junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H115-11 - H115-22 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the H115 No. 4 global can junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H115-9 - H115-20 | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the H61 headup display (meter mirror sub-assembly) connector.
Connect the H115 No. 4 global can junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H61-14 (TX+) - H61-15 (TX-) | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the H6 combination meter assembly connector.
Connect the H115 No. 4 global can junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H6-27 (MSCH) - H6-10 (MSCL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the H80 radio and display receiver assembly connector.
Connect the H115 No. 4 global can junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H80-5 (CNH1) - H80-6 (CNL1) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the H80 radio and display receiver assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H80-5 (CNH1) - H80-6 (CNL1) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the H115 No. 4 global can junction connector.
Connect the H80 radio and display receiver assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H115-10 - H115-21 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the H6 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H6-23 (ES) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| H6-22 (B) - Body ground | Ignition switch off | 11 to 14 V |
| H6-38 (IG+) - Body ground | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the H115 No. 4 global can junction connector.
Connect the H6 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H115-11 - H115-22 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the H115 No. 4 global can junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H115-10 - H115-21 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the H80 radio and display receiver assembly connector.
Connect the H115 No. 4 global can junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H80-5 (CNH1) - H80-6 (CNL1) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the H6 combination meter assembly connector.
Connect the H115 No. 4 global can junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H6-27 (MSCH) - H6-10 (MSCL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the H61 headup display (meter mirror sub-assembly) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H61-4 (ES) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| H61-2 (B) - Body ground | Ignition switch off | 11 to 14 V |
| H61-1 (IG) - Body ground | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the H115 No. 4 global can junction connector.
Connect the H61 headup display (meter mirror sub-assembly) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H115-9 - H115-20 | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the H115 No. 4 global can junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H115-10 - H115-21 | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the H80 radio and display receiver assembly connector.
Connect the H115 No. 4 global can junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H80-5 (CNH1) - H80-6 (CNL1) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the H61 headup display (meter mirror sub-assembly) connector.
Connect the H115 No. 4 global can junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H61-14 (TX+) - H61-15 (TX-) | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG