The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during electric vehicle battery plug assembly removal/installation are shown below.
Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the repair manual.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
To prevent electric shock, wear insulated gloves when working on wire harnesses and components of the high voltage system.
When the cable is disconnected / reconnected to the auxiliary battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.
Learning completes when vehicle is operated normally
1. PRECAUTION
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
G3834
2.REMOVE SERVICE PLUG GRIP
82121
3.DISCONNECT ENGINE WIRE
4.REMOVE CONNECTOR COVER ASSEMBLY
5.CHECK TERMINAL VOLTAGE
6.INSTALL CONNECTOR COVER ASSEMBLY
82121
7.CONNECT ENGINE WIRE
73350C
8.DISCONNECT REAR CENTER SEAT OUTER BELT ASSEMBLY
9.REMOVE BENCH TYPE REAR SEAT CUSHION ASSEMBLY
72693
10.REMOVE REAR SEAT CUSHION LOCK HOOK
76971G
11.REMOVE REAR UNDER COVER
71033
12.REMOVE REAR SEAT CUSHION LEG SUB-ASSEMBLY
G92N1
13.REMOVE HV BATTERY UPPER COVER PANEL
G3830A
14.REMOVE ELECTRIC VEHICLE BATTERY PLUG ASSEMBLY
Be sure to wear insulated gloves and protective goggles.
Disconnect the electric vehicle battery plug assembly connector.
Disengage the claw and open the wiring harness protector.
Disconnect the HV battery junction block assembly connector.
Insulate the disconnected high-voltage connector with insulating tape.
Disconnect the hybrid battery terminal block connector.
Insulate the disconnected high-voltage connector with insulating tape.
Remove the bolt and electric vehicle battery plug assembly from the HV battery.