Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HV BATTERY STACK
RM36W0E _51 Engine / Hybrid System _087936 HYBRID / BATTERY CONTROL _0424601 HV BATTERY STACK G

HYBRID / BATTERY CONTROL  HV BATTERY STACK  INSPECTION  


PROCEDURE

Hide G9508 1.INSPECT HV SUPPLY STACK SUB-ASSEMBLY

CAUTION:

Be sure to wear insulated gloves and protective goggles.


a.

Remove the HV supply stack sub-assembly.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK>REMOVAL


b.

Inspect the HV supply stack sub-assembly.

i.

Check that no electrolyte is leaking from the No. 1 HV supply stack sub-assembly or No. 2 HV supply stack sub-assembly.

A459158C01
1.51,1.219 2.229,1.219 2.229,1.219 1.99,1.052 true 1.531,2.594 2.25,2.594 2.25,2.594 2.01,2.427 true 5.198,2.656 5.917,2.656 5.917,2.656 5.677,2.49 true 5.021,1.271 5.74,1.271 5.74,1.271 5.5,1.104 true 2.458,2 2.792,2 false 4.792,2 5.125,2 false 4.563,1.896 4.875,2.052 0.313,0.156 10 false *1 2.844,1.896 3.156,2.052 0.313,0.156 10 false *2 2.271,1.125 2.583,1.281 0.313,0.156 10 false *a 2.313,2.521 2.625,2.677 0.313,0.156 10 false *a 5.969,2.552 6.281,2.708 0.313,0.156 10 false *a 5.781,1.146 6.094,1.302 0.313,0.156 10 false *a
*1 No. 2 HV Supply Stack Sub-assembly *2 No. 1 HV Supply Stack Sub-assembly
*a Check Part - -


OK:

There is no electrolyte leaking from the HV supply stack sub-assembly.


HINT:

If the result is not as specified, replace the No. 1 HV supply stack sub-assembly or No. 2 HV supply stack sub-assembly.




c.

Install the HV supply stack sub-assembly.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK>INSTALLATION