Home › Power Source / Network › M15A-FKS (BATTERY / CHARGING) › CHARGING SYSTEM › from 2020.07
RM36W0E _57 Power Source / Network _087763 M15A-FKS BATTERY / CHARGING _0419403 CHARGING SYSTEM C

M15A-FKS BATTERY / CHARGING  CHARGING SYSTEM  P065C07  Generator "A" Mechanical Performance Mechanical Failure  


DESCRIPTION

The alternator performs self-diagnosis of its internal circuits to detect malfunctions (open or short circuits).

The ECM receives the result via LIN communication and stores a DTC.

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate Memory Note
P065C07 Generator "A" Mechanical Performance Mechanical Failure Alternator speed is less than 560 rpm, and EXC circuit is ON.
(1 trip detection logic)
·

Fan and generator V belt

·

V-Ribbed belt tensioner assembly

·

Generator assembly wiring

·

Generator assembly


Charge warning light:
Comes on
DTC stored SAE Code: P065C

WIRING DIAGRAM

Refer to the wiring diagram for the P062049.

Click herePower Source / Network>M15A-FKS (BATTERY / CHARGING)>CHARGING SYSTEM>P062049

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following procedure.


PROCEDURE

1.CHECK FAN AND GENERATOR V BELT

OK

2.CHECK V-RIBBED BELT TENSIONER ASSEMBLY

NG

REPAIR OR REPLACE FAN & GENERATOR V BELT

2.CHECK V-RIBBED BELT TENSIONER ASSEMBLY

OK

3.CHECK GENERATOR ASSEMBLY WIRING

NG

REPAIR OR REPLACE V-RIBBED BELT TENSIONER ASSEMBLY

3.CHECK GENERATOR ASSEMBLY WIRING

OK

4.CHECK FOR ABNORMAL NOISE

NG

REPAIR OR REPLACE GENERATOR ASSEMBLY WIRING