The ECM detects changes in the brake booster assembly pressure based on the voltage signal received from the vacuum sensor assembly installed to the brake booster assembly. If the ECM determines that there is a malfunction in the signal sent by the vacuum sensor assembly, it stores DTC P055512 or P055514.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P055512 | Brake Booster Pressure Sensor Circuit High Circuit Short to Battery | The vacuum sensor assembly output voltage is 4.5 V or higher for 1.2 seconds or more (1 trip detection logic). | ·
Open or Short in vacuum sensor assembly circuit ·
Vacuum sensor assembly ·
ECM |
- | DTC stored | Engine | A |
| P055514 | Brake Booster Pressure Sensor Circuit Low Circuit Short to Ground or Open | The vacuum sensor assembly output voltage is 0.5 V or less for 1.2 seconds or more (1 trip detection logic). | ·
Open or Short in vacuum sensor assembly circuit ·
Vacuum sensor assembly ·
ECM |
- | DTC stored | Engine | A |
If there is a defect or an open or short circuit in the vacuum sensor assembly, the voltage level deviates from the normal operating range. The ECM interprets this deviation as a malfunction in the vacuum sensor assembly circuit and stores a DTC.
DTC P055512 and P055514 are detected when the engine idles for 10 seconds or more.
After replacing the ECM, perform idle learning.
Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>SFI SYSTEM>INITIALIZATION
Read freeze frame data using the GTS. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Pre-procedure1
Disconnect the vacuum sensor assembly connector.
Disconnect the ECM connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A28-3 (VC) - A55-56 (BRVC) | Always | Below 1 Ω |
| A28-2 (PB) - A55-54 (PB) | Always | Below 1 Ω |
| A28-1 (E2) - A55-55 (BRE2) | Always | Below 1 Ω |
| A28-3 (VC) or A55-56 (BRVC) - Body ground and other terminals | Always | 10 kΩ or higher |
| A28-2 (PB) or A55-54 (PB) - Body ground and other terminals | Always | 10 kΩ or higher |
| A28-1 (E2) or A55-55 (BRE2) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
Pre-procedure1
Disconnect the vacuum sensor assembly connector.
Turn the ignition switch to ON.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A28-3 (VC) - A28-1 (E2) | Ignition switch ON | 4.75 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK