The intake air temperature sensor is built into the manifold absolute pressure sensor, and monitors the intake air temperature. The intake air temperature sensor has a built-in thermistor that varies its resistance depending on the temperature of the intake air. When the air temperature is low, the resistance in the thermistor increases. When the temperature is high, the resistance drops. The variations in resistance are reflected in the voltage applied to the ECM terminal (See Fig 1).
The intake air temperature sensor is connected to the ECM. The 5 V power source voltage in the ECM is applied to the intake air temperature sensor from terminal THA via resistor R.
Resistor R and the intake air temperature sensor are connected in series. When the resistance value of the intake air temperature sensor changes in accordance with changes in the intake air temperature, the voltage at terminal THA also changes. Based on this signal, the ECM increases the fuel injection volume to improve the drivability during cold engine operation.
When the intake air temperature sensor output is outside the normal range, the ECM determines this to be a malfunction.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P011011 | Intake Air Temperature Sensor 1 Bank 1 Circuit Short to Ground | Intake air temperature sensor output voltage is 0.05 V or less for 0.5 seconds (3 trip detection logic). | ·
Open or short in intake air temperature sensor circuit ·
Short to power source circuit ·
Intake air temperature sensor (manifold absolute pressure sensor) ·
ECM |
Comes on | DTC stored | Engine | A |
| P011015 | Intake Air Temperature Sensor 1 Bank 1 Circuit Short to Battery or Open | Intake air temperature sensor output voltage is 4.95 V or more for 0.5 seconds (3 trip detection logic). | ·
Short in intake air temperature sensor circuit ·
Intake air temperature sensor (manifold absolute pressure sensor) ·
ECM |
Comes on | DTC stored | Engine | A |
When any of these DTCs are output, check the intake air temperature using the GTS. Enter the following menus: Powertrain / Engine / Data List / All Data / Intake Air Temperature.
| Intake Air Temperature | Malfunction |
|---|---|
| -40°C (-40°F) | Open circuit |
| 140°C (284°F) | Short circuit |
DTC P0112 and P0113 are detected when the engine idles for approximately 5 minutes.
After replacing the ECM, perform idle learning.
Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>SFI SYSTEM>INITIALIZATION
Read freeze frame data using the GTS. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Read the value displayed on the GTS.
| Tester Display |
|---|
| Intake Air Temperature |
| Result | Proceed to |
|---|---|
| The value of Intake Air Temperature is -40°C | A |
| The value of Intake Air Temperature is 140°C | B |
If there is an open circuit, the GTS indicates -40°C (-40°F).
If there is a short circuit, the GTS indicates 140°C (284°F).
A
B
Pre-procedure1
Disconnect the manifold absolute pressure sensor connector.
| *1 | Manifold Absolute Pressure Sensor | *2 | ECM |
| *a | Front view of wire harness connector
(to Manifold Absolute Pressure Sensor) |
- | - |
Connect terminals 4 (THA) and 2 (E2) of the manifold absolute pressure sensor connector on the wire harness side.
Procedure1
Read the value displayed on the GTS.
| Tester Display |
|---|
| Intake Air Temperature |
| Result | Proceed to |
|---|---|
| The value of Intake Air Temperature is 140°C | A |
| None of the above conditions are met | B |
140°C = 284°F
Post-procedure1
None.
A
B
Pre-procedure1
Disconnect the manifold absolute pressure sensor connector.
Disconnect the ECM connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D21-4 (THA) - D50-128 (THA) | Always | Below 1 Ω |
| D21-2 (E2) - D50-127 (E21) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
Pre-procedure1
| *1 | Manifold Absolute Pressure Sensor |
| *2 | ECM |
Disconnect the manifold absolute pressure sensor connector.
Procedure1
Read the value displayed on the GTS.
| Tester Display |
|---|
| Intake Air Temperature |
| Result | Proceed to |
|---|---|
| The value of Intake Air Temperature is -40°C | A |
| None of the above conditions are met | B |
-40°C = -40°F
Post-procedure1
None.
A
B
Pre-procedure1
Disconnect the manifold absolute pressure sensor connector.
Disconnect the ECM connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D21-4 (THA) or D50-128 (THA) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG