Home › Engine / Hybrid System › 1KR-FE (ENGINE CONTROL) › SFI SYSTEM › from 2020.07
RM36W0E _51 Engine / Hybrid System _091054 1KR-FE ENGINE CONTROL _0431746 SFI SYSTEM C

1KR-FE ENGINE CONTROL  SFI SYSTEM  P013013  O2 (A/F) Sensor Circuit Bank 1 Sensor 1 Circuit Open  P219523  A/F (O2) Sensor Signal Biased/Stuck Lean Bank 1 Sensor 1 Signal Stuck Low  P219624  A/F (O2) Sensor Signal Biased/Stuck Rich Bank 1 Sensor 1 Signal Stuck High  


DESCRIPTION

In order to obtain a high purification rate for the carbon monoxide (CO), hydrocarbon (HC) and nitrogen oxide (NOx) components in the exhaust gas, a Three-Way Catalytic Converter (TWC) is used. For the most efficient use of the TWC, the air-fuel ratio must be precisely controlled so that it is always close to the stoichiometric air-fuel ratio. The heated oxygen sensor has the characteristic whereby its output voltage changes suddenly in the vicinity of the stoichiometric air-fuel ratio. This is used to detect the oxygen concentration in the exhaust gas and provide the ECM with feedback to control the air-fuel ratio. When the air-fuel ratio becomes lean, the oxygen concentration in the exhaust gas increases. The heated oxygen sensor informs the ECM of the lean condition (low voltage, i.e. less than 0.45 V). When the air-fuel ratio is richer than the stoichiometric air-fuel level, the oxygen concentration in the exhaust gas is reduced. And the heated oxygen sensor informs the ECM of the rich condition (high voltage, i.e. more than 0.45 V). The ECM judges by the voltage output of the heated oxygen sensor whether the air-fuel ratio is rich or lean and controls the injection time accordingly. If a malfunction of the heated oxygen sensor causes an output of abnormal voltage, the ECM is unable to perform accurate air-fuel ratio control. The heated oxygen sensor includes a heater which heats the zirconia element. The heater is controlled by the ECM. When the intake air volume is low (the temperature of the exhaust gas is low), a current flows to the heater in order to heat the sensor for accurate oxygen concentration detection.

A313385E01
2.313,2.25 2.5,2.25 false 1.667,1.74 2.115,2.167 true 2.542,2.198 3.052,2.417 0.51,0.219 10 false Cover 0.75,2.417 1.677,2.656 0.927,0.24 10 false Exhaust Gas 1.115,1.667 1.677,1.833 0.563,0.167 10 false Element 3.219,1.292 4.396,1.688 1.177,0.396 10 false Output Voltage 4.083,2.229 6.083,2.49 2,0.26 10 false Richer - Air Fuel Ratio - Leaner 4.49,0.177 6.031,0.385 1.542,0.208 10 false Ideal Air Fuel Mixture

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory DTC Output from Priority
P013013 O2 (A/F) Sensor Circuit Bank 1 Sensor 1 Circuit Open

All of the following conditions are met (3 trip detection logic):

(a)

100 seconds have elapsed since heated oxygen sensor dew point judgment* was completed.

(b)

Heated oxygen sensor (sensor 1) output voltage is between 1.25 and 3.5 V.

(c)

Conditions (a) and (b) are met continuously for 5 seconds.

(d)

Active air-fuel ratio control is performed as follows after condition (c) is met:

(1)

Pulse signal is applied to heated oxygen sensor (sensor 1) signal line.

(2)

Heated oxygen sensor (sensor 1) output voltage is measured after pulse signal is applied.

(3)

Heated oxygen sensor (sensor 1) output voltage after pulse signal is applied is 2.8 V or more.

(4)

When condition (3) is met, steps (1) and (2) are repeated 2 more times.


(e)

Average difference in heated oxygen sensor (sensor 1) output voltage when active air-fuel ratio control is performed 3 times is 2.8 V or more.



·

Open or short in heated oxygen sensor (sensor 1) circuit

·

Heated oxygen sensor (sensor 1)

·

ECM


Comes on DTC stored Engine A
P219523 A/F (O2) Sensor Signal Biased/Stuck Lean Bank 1 Sensor 1 Signal Stuck Low

Heated oxygen sensor (sensor 1) is stuck lean:

All of the following conditions are met (3 trip detection logic):

(1)

While heated oxygen sensor (sensor 1) is used to perform air-fuel ratio feedback control, calculated intake air volume is 220 g or more.

(2)

Heated oxygen sensor (sensor 1) output voltage is less than 0.55 V.

(3)

Heated oxygen sensor (sensor 2) is judged as active and output voltage is 0.78 V or more.

(4)

Conditions (1), (2) and (3) are met for 1 second or more.

(5)

100 seconds have elapsed since condition (4) was met and heated oxygen sensor dew point judgment* was completed.




·

Short to GND in heated oxygen sensor (sensor 1) circuit

·

Heated oxygen sensor (sensor 1)

·

ECM


Comes on DTC stored Engine A
P219624 A/F (O2) Sensor Signal Biased/Stuck Rich Bank 1 Sensor 1 Signal Stuck High

Heated oxygen sensor (sensor 1) is stuck rich:

All of the following conditions are met (3 trip detection logic):

(1)

While heated oxygen sensor (sensor 1) is used to perform air-fuel ratio feedback control, calculated intake air volume is 220 g or more.

(2)

Heated oxygen sensor (sensor 1) output voltage is between 0.55 and 3.5 V.

(3)

Heated oxygen sensor (sensor 2) is judged as active and output voltage is less than 0.25 V.

(4)

Conditions (1), (2) and (3) are met for 1 second or more.

(5)

100 seconds have elapsed since condition (4) was met and heated oxygen sensor dew point judgment* was completed.




·

Short to GND in heated oxygen sensor (sensor 1) circuit

·

Heated oxygen sensor (sensor 1)

·

ECM


Comes on DTC stored Engine A

HINT:
·

*: Condensation may form in the exhaust pipes after the engine is started and before the exhaust system has warmed up. If condensation exists, the sensor element may be damaged if the heated oxygen sensor (sensor 1) heater is heated excessively. Therefore, the ECM will restrict the output of the heated oxygen sensor (sensor 1) heater until it determines condensation is not forming in the exhaust pipes. Dew point judgment is when the ECM judges that condensation is no longer forming.

·

The internal resistance of the heated oxygen sensor (sensor 1) cannot be measured using a tester.

·

Sensor 1 refers to the sensor near the engine assembly.

·

The output voltage of the heated oxygen sensor (sensor 1) and the short-term fuel trim value can be read using the GTS.



WIRING DIAGRAM

A459173E01
4.927,0.542 5.385,0.74 0.458,0.198 10 false A55 4.917,1.229 5.375,1.427 0.458,0.198 10 false D50 4.917,1.625 5.375,1.823 0.458,0.198 10 false D50 4.917,2.063 5.375,2.26 0.458,0.198 10 false D50 4.917,3.521 5.375,3.719 0.458,0.198 10 false D50 4.917,3.958 5.375,4.156 0.458,0.198 10 false D50 4.906,4.406 5.365,4.604 0.458,0.198 10 false D50 4.927,5 5.385,5.198 0.458,0.198 10 false D50 5.063,0.354 5.219,0.552 0.156,0.198 10 false 9 5.281,0.542 5.896,0.74 0.615,0.198 10 false MREL 5.281,1.125 5.896,1.323 0.615,0.198 10 false HT1A 5.271,1.521 5.885,1.719 0.615,0.198 10 false OX1A 5.292,1.958 5.75,2.156 0.458,0.198 10 false E11 5.281,3.417 5.896,3.615 0.615,0.198 10 false HT1B 5.271,3.854 5.885,4.052 0.615,0.198 10 false OX1B 5.271,4.313 5.729,4.51 0.458,0.198 10 false E12 5.281,4.99 5.896,5.188 0.615,0.198 10 false DE12 5.906,5.646 6.365,5.844 0.458,0.198 10 false ECM 5.031,1.01 5.344,1.208 0.313,0.198 10 false 25 4.969,1.438 5.427,1.635 0.458,0.198 10 false 126 4.979,1.865 5.438,2.063 0.458,0.198 10 false 125 5.042,3.313 5.354,3.51 0.313,0.198 10 false 24 4.969,3.75 5.427,3.948 0.458,0.198 10 false 124 4.979,4.219 5.438,4.417 0.458,0.198 10 false 123 4.979,4.781 5.438,4.979 0.458,0.198 10 false 122 4.396,2.281 4.552,2.479 0.156,0.198 10 false * 4.552,4.625 4.708,4.823 0.156,0.198 10 false * 4.031,1.125 4.188,1.323 0.156,0.198 10 false 2 4.031,1.531 4.188,1.729 0.156,0.198 10 false 4 4.021,1.958 4.177,2.156 0.156,0.198 10 false 3 3.583,1.115 4.198,1.313 0.615,0.198 10 false HT1A 3.583,1.521 4.198,1.719 0.615,0.198 10 false OX1A 3.76,1.969 4.073,2.167 0.313,0.198 10 false E1 3.031,1.125 3.344,1.323 0.313,0.198 10 false +B 2.875,1.115 3.031,1.313 0.156,0.198 10 false 1 2.729,2.438 3.042,2.635 0.313,0.198 10 false D38 2.708,2.604 4.24,2.99 1.531,0.385 10 false Heated Oxygen Sensor (Sensor 1) 4.031,3.406 4.188,3.604 0.156,0.198 10 false 2 4.042,3.813 4.198,4.01 0.156,0.198 10 false 4 4.031,4.302 4.188,4.5 0.156,0.198 10 false 3 3.573,3.406 4.188,3.604 0.615,0.198 10 false HT1B 3.604,3.844 4.219,4.042 0.615,0.198 10 false OX1B 3.76,4.302 4.073,4.5 0.313,0.198 10 false E1 3.042,3.427 3.354,3.625 0.313,0.198 10 false +B 2.677,4.74 2.99,4.938 0.313,0.198 10 false D85 2.667,4.917 4.198,5.302 1.531,0.385 10 false Heated Oxygen Sensor (Sensor 2) 1.625,1.167 3,1.365 1.375,0.198 10 false EFI NO. 3 1.094,1.365 1.25,1.563 0.156,0.198 10 false 1 1.115,2.167 1.271,2.365 0.156,0.198 10 false 2 0.385,1.354 0.542,1.552 0.156,0.198 10 false 5 0.365,2.177 0.521,2.375 0.156,0.198 10 false 3 1.323,1.75 3.469,1.948 2.146,0.198 10 false EFI-MAIN NO. 1 0.594,3.281 2.74,3.479 2.146,0.198 10 false EFI-MAIN NO. 1 0.604,4.177 2.75,4.375 2.146,0.198 10 false BATT-MAIN NO. 1 0.771,5.052 1.844,5.25 1.073,0.198 10 false Battery 2.135,5.833 3.823,6.031 1.688,0.198 10 false *: Shielded 2.854,3.396 3.01,3.594 0.156,0.198 10 false 1

CONFIRMATION DRIVING PATTERN

CAUTION:

When performing the confirmation driving pattern, obey all speed limits and traffic laws.


DTC P013013, P219523 and P219624 are detected when the vehicle is driven in an urban area at an average vehicle speed of approximately 50 km/h (31 mph) for approximately 30 minutes.

CAUTION / NOTICE / HINT

HINT:

It is possible that the malfunctioning area can be found using the Active Test. The Active Test can determine if the heated oxygen sensor or other potential trouble areas are malfunctioning or not.

The injection volume can be switched to -12.5% (decrease) or +12.5% (increase) by the Active Test.

The Active Test procedure enables a technician to check and graph the output voltage of the heated oxygen sensors.


Procedure:

(a)

Connect the GTS to the DLC3.

(b)

Turn the ignition switch to ON.

(c)

Turn the GTS on.

(d)

Warm up the engine by running the engine at 2500 rpm for approximately 90 seconds.

(e)

Enter the following menus: Powertrain / Engine / Active Test / Control the Injection Volume for A/F Sensor / All Data / O2 Sensor Voltage B1S1 and O2 Sensor Voltage B1S2.

(f)

Perform the Active Test while the engine is idling (press the RIGHT or LEFT button to change the fuel injection volume).

(g)

Monitor the output voltages of the heated oxygen sensor (sensor 1) and heated oxygen sensor (sensor 2) (O2 Sensor Voltage B1S1 and O2 Sensor Voltage B1S2) displayed on the GTS.



Standard:

The heated oxygen sensors reacts in accordance with the increase and decrease of injection volume:

+12.5% → Rich output: Higher than 0.55 V

-12.5% → Lean output: Below 0.4 V


NOTICE:
·

The heated oxygen sensor (sensor 1) has an output delay of a few seconds and the heated oxygen sensor (sensor 2) has a maximum output delay of 20 seconds.

·

If the vehicle is short on fuel, the air fuel ratio becomes lean and DTCs will be stored.



A342237E01
0.135,0.688 0.75,0.885 0.615,0.198 10 false Case 0.229,2.167 0.844,2.365 0.615,0.198 10 false 1 0.25,4.271 0.865,4.469 0.615,0.198 10 false 2 0.24,6.292 0.854,6.49 0.615,0.198 10 false 3 0.26,8.354 0.875,8.552 0.615,0.198 10 false 4 0.771,0.5 2.885,0.906 2.115,0.406 10 false Heated Oxygen Sensor (Sensor 1) Output Voltage 3.469,0.49 5.583,0.896 2.115,0.406 10 false Heated Oxygen Sensor (Sensor 2) Output Voltage 5.948,0.51 6.979,0.906 1.031,0.396 10 false Main Suspected Trouble Area 0.74,1.344 2.031,1.583 1.292,0.24 10 false Injection Volume 1.479,1.594 2.771,1.833 1.292,0.24 9 false 12.5% 1.427,1.854 2.719,2.094 1.292,0.24 9 false -12.5% 0.698,2.302 1.99,2.542 1.292,0.24 10 false Output Voltage 0.792,2.583 2.083,2.823 1.292,0.24 9 false Higher than 0.55 V 1.167,2.844 2.458,3.083 1.292,0.24 9 false Below 0.4 V 2.615,2.688 3.906,2.927 1.292,0.24 9 false OK 4.115,1.594 5.406,1.833 1.292,0.24 9 false 12.5% 4.073,1.823 5.365,2.063 1.292,0.24 9 false -12.5% 3.302,2.292 4.594,2.531 1.292,0.24 10 false Output Voltage 3.375,2.573 4.667,2.813 1.292,0.24 9 false Higher than 0.55 V 3.74,2.844 5.031,3.083 1.292,0.24 9 false Below 0.4 V 5.146,2.677 6.438,2.917 1.292,0.24 9 false OK 6.354,2.177 6.969,2.375 0.615,0.198 10 false - 0.76,3.417 2.052,3.656 1.292,0.24 10 false Injection Volume 1.448,3.698 2.74,3.938 1.292,0.24 9 false 12.5% 1.427,3.917 2.719,4.156 1.292,0.24 9 false -12.5% 0.719,4.385 2.01,4.625 1.292,0.24 10 false Output Voltage 2.615,4.74 3.906,4.979 1.292,0.24 9 false NG 0.729,4.813 2.021,5.052 1.292,0.24 9 false Almost no reaction 3.365,1.333 4.656,1.573 1.292,0.24 10 false Injection Volume 3.396,3.417 4.688,3.656 1.292,0.24 10 false Injection Volume 4.083,3.667 5.375,3.906 1.292,0.24 9 false 12.5% 4.052,3.896 5.344,4.135 1.292,0.24 9 false -12.5% 3.281,4.354 4.573,4.594 1.292,0.24 10 false Output Voltage 3.396,4.677 4.688,4.917 1.292,0.24 9 false Higher than 0.55 V 3.802,4.938 5.094,5.177 1.292,0.24 9 false Below 0.4 V 5.188,4.823 6.479,5.063 1.292,0.24 9 false OK 5.865,3.469 6.969,4.115 1.104,0.646 10 false - Heated oxygen sensor (sensor 1) 5.844,4.25 6.948,4.896 1.104,0.646 10 false - Heated oxygen sensor (sensor 1) circuit 0.719,5.448 2.01,5.688 1.292,0.24 10 false Injection Volume 1.458,5.75 2.75,5.99 1.292,0.24 9 false 12.5% 1.448,5.948 2.74,6.188 1.292,0.24 9 false -12.5% 0.792,6.417 2.083,6.656 1.292,0.24 10 false Output Voltage 0.708,6.729 2,6.969 1.292,0.24 9 false Higher than 0.55 V 1.063,7 2.354,7.24 1.292,0.24 9 false Below 0.4 V 2.563,6.875 3.854,7.115 1.292,0.24 9 false OK 3.365,5.458 4.656,5.698 1.292,0.24 10 false Injection Volume 4.073,5.729 5.365,5.969 1.292,0.24 9 false 12.5% 4.052,5.938 5.344,6.177 1.292,0.24 9 false -12.5% 3.396,6.406 4.688,6.646 1.292,0.24 10 false Output Voltage 3.365,6.885 4.656,7.125 1.292,0.24 9 false Almost no reaction 5.177,6.75 6.469,6.99 1.292,0.24 9 false NG 5.885,5.563 6.99,6.208 1.104,0.646 10 false - Heated oxygen sensor (sensor 2) 5.885,6.333 6.99,6.979 1.104,0.646 10 false - Heated oxygen sensor (sensor 2) circuit 0.75,7.521 2.042,7.76 1.292,0.24 10 false Injection Volume 1.479,7.802 2.771,8.042 1.292,0.24 9 false 12.5% 1.438,8.01 2.729,8.25 1.292,0.24 9 false -12.5% 0.76,8.438 2.052,8.677 1.292,0.24 10 false Output Voltage 0.74,8.917 2.031,9.156 1.292,0.24 9 false Almost no reaction 2.563,8.823 3.854,9.063 1.292,0.24 9 false NG 3.302,7.531 4.594,7.771 1.292,0.24 10 false Injection Volume 4.104,7.802 5.396,8.042 1.292,0.24 9 false 12.5% 4.063,8.042 5.354,8.281 1.292,0.24 9 false -12.5% 3.344,8.396 4.635,8.635 1.292,0.24 10 false Output Voltage 3.385,8.927 4.677,9.167 1.292,0.24 9 false Almost no reaction 5.177,8.802 6.469,9.042 1.292,0.24 9 false NG 5.833,7.802 6.938,8.448 1.104,0.646 10 false - Fuel system 5.833,8.365 6.938,9.01 1.104,0.646 10 false - Gas leak from exhaust system

The following procedure enables the technician to check and graph the voltage outputs of both the heated oxygen sensors.

To display the graph, enter the following menus: Powertrain / Engine / Active Test / Control the Injection Volume for A/F Sensor / All Data / O2 Sensor Voltage B1S1 and O2 Sensor Voltage B1S2; then press the view button.


NOTICE:

After replacing the ECM, perform idle learning.

Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>SFI SYSTEM>INITIALIZATION


HINT:
·

Sensor 1 refers to the sensor closest to the engine assembly.

·

Sensor 2 refers to the sensor farthest away from the engine assembly.

·

Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.



PROCEDURE

1.READ VALUE USING GTS (O2 SENSOR VOLTAGE B1S1)

Pre-procedure1

a.

Warm up the heated oxygen sensor (sensor 1) at an engine speed of 2500 rpm for approximately 90 seconds.


Procedure1

b.

Read the output voltage of the heated oxygen sensor (sensor 1) during engine idling.

Powertrain > Engine > Data List
Tester Display
O2 Sensor Voltage B1S1
50003 372 1305
Standard voltage:

Fluctuates between less than 0.4 V, and higher than 0.55 V (see the following figure).


A319417E01
1.24,1.313 2.156,1.51 0.917,0.198 10 false 0.55 V 1.313,1.625 2.229,1.823 0.917,0.198 10 false 0.4 V 1.427,1.948 1.76,2.135 0.333,0.188 10 false 0 V 1.427,0.99 1.802,1.188 0.375,0.198 10 false 1 V


Result:
Proceed to
OK
NG


Post-procedure1

c.

None.



OK

2.CLEAR DTC

NG

7.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR (SENSOR 1) - ECM)
2.CLEAR DTC

Pre-procedure1

a.

None.


Procedure1

b.

Clear the DTCs.

Powertrain > Engine > Clear DTCs
50002 372

Result:
Proceed to
NEXT


Post-procedure1

c.

Turn the ignition switch off and wait for at least 30 seconds.



NEXT

3.CHECK WHETHER DTC OUTPUT RECURS (DTC P013013, P219523 OR P219624)
3.CHECK WHETHER DTC OUTPUT RECURS (DTC P013013, P219523 OR P219624)

Pre-procedure1

a.

Start the engine and warm it up.


b.

Drive the vehicle in accordance with the driving pattern described in Confirmation Driving Pattern.


Procedure1

c.

Read the pending DTCs.

Powertrain > Engine > Trouble Codes
50001 372

Result:
Result Proceed to
P013013, P219523 or P219624 is output A
DTCs are not output B


Post-procedure1

d.

None.



A

4.REPLACE HEATED OXYGEN SENSOR (SENSOR 1)

B

4.REPLACE HEATED OXYGEN SENSOR (SENSOR 1)

NEXT

5.CLEAR DTC
5.CLEAR DTC

Pre-procedure1

a.

None.


Procedure1

b.

Clear the DTCs.

Powertrain > Engine > Clear DTCs
50002 372

Result:
Proceed to
NEXT


Post-procedure1

c.

Turn the ignition switch off and wait for at least 30 seconds.



NEXT

6.CHECK WHETHER DTC OUTPUT RECURS (DTC P013013, P219523 OR P219624)
6.CHECK WHETHER DTC OUTPUT RECURS (DTC P013013, P219523 OR P219624)

Pre-procedure1

a.

Start the engine and warm it up.


b.

Drive the vehicle in accordance with the driving pattern described in Confirmation Driving Pattern.


Procedure1

c.

Read the pending DTCs.

Powertrain > Engine > Trouble Codes
50001 372

Result:
Result Proceed to
P013013, P219523 or P219624 is output A
DTCs are not output B


Post-procedure1

d.

None.



A

B

END

7.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR (SENSOR 1) - ECM)

Pre-procedure1

a.

Disconnect the heated oxygen sensor (sensor 1) connector.


b.

Disconnect the ECM connector.


Procedure1

c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D38-4 (OX1A) - D50-126 (OX1A) Always Below 1 Ω
D38-2 (HT1A) - D50-25 (HT1A) Always Below 1 Ω
D38-3 (E1) - D50-125 (E11) Always Below 1 Ω
D38-4 (OX1A) or D50-126 (OX1A) - Body ground Always 10 kΩ or higher
D38-2 (HT1A) or D50-25 (HT1A) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG


Post-procedure1

d.

None.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR