Home › Power Source / Network › NETWORKING › CAN COMMUNICATION SYSTEM (for HV Model) › 2020.07–2021.04
RM36W0E _57 Power Source / Network _088060 NETWORKING _0424238 CAN COMMUNICATION SYSTEM(for HV Model) U

NETWORKING  CAN COMMUNICATION SYSTEM(for HV Model)  TERMINALS OF ECU  


NOTICE:
·

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION

·

Before measuring the resistance of the CAN bus, turn the ignition switch off and leave the vehicle for 1 minute or more without operating the key or any switches, or opening or closing the doors. After that, disconnect the cable from the negative (-) auxiliary battery terminal and leave the vehicle for 1 minute or more before measuring the resistance.

·

This section describes the standard values for all CAN related components.



HINT:
·

The systems (ECUs and sensors) that use CAN communication vary depending on the vehicle and optional equipment. Check which systems (ECUs and sensors) are installed to the vehicle.

Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM (for HV Model)>DIAGNOSIS SYSTEM

·

Operating the ignition switch, any other switches or a door triggers related ECU and sensor communication on the CAN. This communication will cause the resistance value to change.

·

Even after DTCs are cleared, if a DTC is stored again after driving the vehicle for a while, the malfunction may be occurring due to vibration of the vehicle. In such a case, wiggling the ECUs or wire harness while performing the inspection below may help determine the cause of the malfunction.



NO. 1 GLOBAL CAN JUNCTION CONNECTOR (for TMC Made)


a.

Check the No. 1 global CAN junction connector.

i.

Connection diagram

C422304C08
1.521,0.74 2.021,0.99 0.5,0.25 0.167,0.135 0.479,0.333 0.313,0.198 10 false *a 1.604,0.792 2.021,0.99 0.417,0.198 10 false H110
*a Front view of wire harness connector
(to No. 1 Global CAN Junction Connector)
- -



ii.

Check the connection diagram of the components which are connected to the No. 1 global CAN junction connector.

Terminal No. (Symbol) Wiring Color Connected to
H110-1 (CANH) LG Power steering ECU assembly
(for Bus 4)
H110-12 (CANL) W
H110-2 (CANH) SB Steering sensor
(for Bus 4)
H110-13 (CANL) W
H110-3 (CANH) P Brake booster with master cylinder assembly
(for Bus 4)
H110-14 (CANL) W
H110-4 (CANH) BR No. 2 global CAN junction connector
(for Bus 4)
H110-15 (CANL) W




NO. 1 GLOBAL CAN JUNCTION CONNECTOR (for TMMF Made)


a.

Check the No. 1 global CAN junction connector.

i.

Connection diagram

C441922C01
1.833,0.75 2.333,1 0.5,0.25 0.094,0.094 0.406,0.292 0.313,0.198 10 false *a 1.906,0.771 2.375,1.031 0.469,0.26 10 false H111
*a Front view of wire harness connector
(to No. 1 Global CAN Junction Connector)
- -



ii.

Check the connection diagram of the components which are connected to the No. 1 global CAN junction connector.

Terminal No. (Symbol) Wiring Color Connected to
H111-1 (CANH) LG Power steering ECU assembly
(for Bus 4)
H111-7 (CANL) W
H111-2 (CANH) SB Steering sensor
(for Bus 4)
H111-8 (CANL) W
H111-3 (CANH) L Brake booster with master cylinder assembly
(for Bus 4)
H111-9 (CANL) W
H111-4 (CANH) BR No. 2 global CAN junction connector
(for Bus 4)
H111-10 (CANL) W




NO. 2 GLOBAL CAN JUNCTION CONNECTOR (for TMC Made)


a.

Check the No. 2 global CAN junction connector.

i.

Connection diagram

C422304C09
1.521,0.74 2.021,0.99 0.5,0.25 0.167,0.135 0.479,0.333 0.313,0.198 10 false *a 1.604,0.792 2.021,0.99 0.417,0.198 10 false H113
*a Front view of wire harness connector
(to No. 2 Global CAN Junction Connector)
- -



ii.

Check the connection diagram of the components which are connected to the No. 2 global CAN junction connector.

Terminal No. (Symbol) Wiring Color Connected to
H113-1 (CANH) B Air bag sensor assembly
(for Bus 4)
H113-12 (CANL) W
H113-2 (CANH) V Central gateway ECU (network gateway ECU)
(for Bus 4)
H113-13 (CANL) W
H113-4 (CANH) BR No. 1 global CAN junction connector
(for Bus 4)
H113-15 (CANL) W




NO. 2 GLOBAL CAN JUNCTION CONNECTOR (for TMMF Made)


a.

Check the No. 2 global CAN junction connector.

i.

Connection diagram

C441922C02
1.833,0.75 2.333,1 0.5,0.25 0.094,0.094 0.406,0.292 0.313,0.198 10 false *a 1.906,0.771 2.365,0.979 0.458,0.208 10 false H112
*a Front view of wire harness connector
(to No. 2 Global CAN Junction Connector)
- -



ii.

Check the connection diagram of the components which are connected to the No. 2 global CAN junction connector.

Terminal No. (Symbol) Wiring Color Connected to
H112-1 (CANH) B Airbag sensor assembly
(for Bus 4)
H112-7 (CANL) W
H112-2 (CANH) V Central gateway ECU (network gateway ECU)
(for Bus 4)
H112-8 (CANL) W
H112-3 (CANH) G Brake actuator assembly
(for Bus 4)
H112-9 (CANL) W
H112-4 (CANH) BR No. 1 global CAN junction connector
(for Bus 4)
H112-10 (CANL) W




NO. 3 GLOBAL CAN JUNCTION CONNECTOR


a.

Check the No. 3 global CAN junction connector.

i.

Connection diagram

C422304C10
1.51,0.781 2.01,1.031 0.5,0.25 0.094,0.104 0.406,0.26 0.313,0.156 10 false *a 1.604,0.833 2.031,1.042 0.427,0.208 10 false H114
*a Front view of wire harness connector
(to No. 3 Global CAN Junction Connector)
- -



ii.

Check the connection diagram of the components which are connected to the No. 3 global CAN junction connector.

Terminal No. (Symbol) Wiring Color Connected to
H114-1 (CANH) B Central gateway ECU (network gateway ECU)
(for Bus 5)
H114-12 (CANL) W
H114-2 (CANH) SB Main body ECU (multiplex network body ECU)
(for Bus 5)
H114-13 (CANL) W
H114-3 (CANH) R Air conditioning amplifier assembly
(for Bus 5)
H114-14 (CANL) W
H114-4 (CANH) L Certification ECU (smart key ECU assembly)
(for Bus 5)
H114-15 (CANL) W




NO. 4 GLOBAL CAN JUNCTION CONNECTOR


a.

Check the No. 4 global CAN junction connector.

i.

Connection diagram

C422304C11
1.521,0.74 2.021,0.99 0.5,0.25 0.167,0.135 0.479,0.333 0.313,0.198 10 false *a 1.615,0.792 2.031,0.99 0.417,0.198 10 false H115
*a Front view of wire harness connector
(to No. 4 Global CAN Junction Connector)
- -



ii.

Check the connection diagram of the components which are connected to the No. 4 global CAN junction connector.

Terminal No. (Symbol) Wiring Color Connected to
H115-1 (CANH) R Central gateway ECU (network gateway ECU)
(for Bus 3)
H115-12 (CANL) W
H115-2 (CANH) BR Combination meter assembly
(for Bus 3)
H115-13 (CANL) W
H115-3 (CANH) LG Radio and display receiver assembly
(for Bus 3)
H115-14 (CANL) W
H115-4 (CANH) BE Telephone transceiver assembly
(for Bus 3)
H115-15 (CANL) W
H115-5 (CANH) SB Meter mirror sub-assembly
(for Bus 3)
H115-16 (CANL) W




NO. 5 GLOBAL CAN JUNCTION CONNECTOR


a.

Check the No. 5 global CAN junction connector.

i.

Connection diagram

C422304C12
1.521,0.74 2.021,0.99 0.5,0.25 0.167,0.135 0.479,0.333 0.313,0.198 10 false *a 1.604,0.792 2.021,0.99 0.417,0.198 10 false H116
*a Front view of wire harness connector
(to No. 5 Global CAN Junction Connector)
- -



ii.

Check the connection diagram of the components which are connected to the No. 5 global CAN junction connector.

Terminal No. (Symbol) Wiring Color Connected to
H116-1 (CANH) Y ECM
(for Bus 2)
H116-12 (CANL) W
H116-2 (CANH) G Inverter with converter assembly
(for Bus 2)
H116-13 (CANL) W
H116-3 (CANH) GR Vehicle approaching speaker controller
(for Bus 2)
H116-14 (CANL) W
H116-4 (CANH) LG Hybrid vehicle control ECU
(for Bus 2)
H116-15 (CANL) W
H116-5 (CANH) BE No. 10 global CAN junction connector
(for Bus 2)
H116-16 (CANL) W
H116-7 (CANH) R Brake booster with master cylinder assembly
(for Powertrain Local Bus)
H116-18 (CANL) W
H116-8 (CANH) V Brake actuator assembly
(for Powertrain Local Bus)
H116-19 (CANL) W
H116-9 (CANH) B ECM
(for Powertrain Local Bus)
H116-20 (CANL) W
H116-10(CANH) P Hybrid vehicle control ECU
(for Powertrain Local Bus)
H116-21(CANL) W




NO. 7 GLOBAL CAN JUNCTION CONNECTOR


a.

Check the No. 7 global CAN junction connector.

i.

Connection diagram

C422304C13
1.521,0.74 2.021,0.99 0.5,0.25 0.167,0.135 0.479,0.333 0.313,0.198 10 false *a 1.604,0.792 2.021,0.99 0.417,0.198 10 false H118
*a Front view of wire harness connector
(to No. 7 Global CAN Junction Connector)
- -



ii.

Check the connection diagram of the components which are connected to the No. 7 global CAN junction connector.

Terminal No. (Symbol) Wiring Color Connected to
H118-1 (CANH) R Forward recognition camera
(for Bus 1)
H118-12 (CANL) W
H118-2 (CANH) SB Central gateway ECU (network gateway ECU)
(for Bus 1)
H118-13 (CANL) W
H118-3 (CANH) L Millimeter wave radar sensor assembly
(for Bus 1)
H118-14 (CANL) W
H118-4 (CANH) V No. 8 global CAN junction connector
(for Bus 1)
H118-15 (CANL) W




NO. 8 GLOBAL CAN JUNCTION CONNECTOR


a.

Check the No. 8 global CAN junction connector.

i.

Connection diagram

C422306C04
1.51,0.781 2.01,1.031 0.5,0.25 0.115,0.094 0.427,0.25 0.313,0.156 10 false *a 1.635,0.823 1.948,0.979 0.313,0.156 10 false O85
*a Front view of wire harness connector
(to No. 8 Global CAN Junction Connector)
- -



ii.

Check the connection diagram of the components which are connected to the No. 8 global CAN junction connector.

Terminal No. (Symbol) Wiring Color Connected to
O85-1 (CANH) BE Clearance warning ECU assembly
(for Bus 1)
O85-12 (CANL) W
O85-2 (CANH) V No. 7 global CAN junction connector
(for Bus 1)
O85-13 (CANL) W
O85-3 (CANH) GR Blind spot monitor sensor LH
(for Bus 1)
O85-14 (CANL) W
O85-4 (CANH) LG Rear television camera assembly
(for Bus 1)
O85-15 (CANL) W
O85-5 (CANH) R No. 1 CAN junction terminal
(for Bus 1)
O85-16 (CANL) W




NO. 9 GLOBAL CAN JUNCTION CONNECTOR


a.

Check the No. 9 global CAN junction connector.

i.

Connection diagram

C422306C10
1.51,0.781 2.01,1.031 0.5,0.25 0.115,0.094 0.427,0.25 0.313,0.156 10 false *a 1.615,0.823 1.927,0.979 0.313,0.156 10 false O87
*a Front view of wire harness connector
(to No. 9 Global CAN Junction Connector)
- -



ii.

Check the connection diagram of the components which are connected to the No. 9 global CAN junction connector.

Terminal No. (Symbol) Wiring Color Connected to
O87-1 (CANH) G Central gateway ECU (network gateway ECU)
(for Bus 6)
O87-12 (CANL) W
O87-2 (CANH) L Central gateway ECU (network gateway ECU)
(for Bus 6)
O87-13 (CANL) W
O87-4 (CANH) R Tire pressure warning ECU and receiver
(for Bus 6)
O87-15 (CANL) W




NO. 10 GLOBAL CAN JUNCTION CONNECTOR


a.

Check the No. 10 global CAN junction connector.

i.

Connection diagram

C422306C05
1.51,0.781 2.01,1.031 0.5,0.25 0.115,0.094 0.427,0.25 0.313,0.156 10 false *a 1.635,0.833 1.948,0.99 0.313,0.156 10 false O88
*a Front view of wire harness connector
(to No. 10 Global CAN Junction Connector)
- -



ii.

Check the connection diagram of the components which are connected to the No. 10 global CAN junction connector.

Terminal No. (Symbol) Wiring Color Connected to
O88-1 (CANH) BE No. 5 global CAN junction connector
(for Bus 2)
O88-12 (CANL) W
O88-3 (CANH) SB Battery ECU assembly
(for Bus 2)
O88-14 (CANL) W
O88-4 (CANH) LG Central gateway ECU (network gateway ECU)
(for Bus 2)
O88-15 (CANL) W




NO. 1 CAN JUNCTION TERMINAL


a.

Check the No. 1 CAN junction terminal.

i.
C395263C20
2.75,0.833 3.271,1.083 0.521,0.25 0.104,0.094 0.417,0.25 0.313,0.156 10 false *a 2.865,0.875 3.208,1.042 0.344,0.167 10 false O86
*a Rear view of wire harness connector
(to No. 1 CAN Junction Terminal)


Connection diagram


ii.

Check the connection diagram of the components which are connected to the No. 1 CAN junction terminal.

Terminal No. (Symbol) Wiring Color Connected to
O86-3 (CANH) R No. 8 global CAN junction connector
(for Bus 1)
O86-2 (CANL) W




DLC3


a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Measure the resistance according to the value(s) in the table below.

C427140C05
1.531,0.76 1.927,1.052 0.396,0.292 0.104,0.115 0.417,0.313 0.313,0.198 10 false *1 1.646,0.813 2.063,1.115 0.417,0.302 10 false H3
*1 DLC3 - -


Standard Resistance:
Terminal No. (Symbol) Terminal Description Condition Specified Condition
H3-6 (CANH) - H3-14 (CANL) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
H3-6 (CANH) - H3-4 (CG) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H3-14 (CANL) - H3-4 (CG) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H3-6 (CANH) - H3-16 (BAT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
H3-14 (CANL) - H3-16 (BAT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU)


C422307C03
3.49,0.135 3.906,0.385 0.417,0.25 0.188,0.198 0.5,0.396 0.313,0.198 10 false *a 3.594,0.198 4.052,0.396 0.458,0.198 10 false H40
*a Component without harness connected
(Central Gateway ECU (Network Gateway ECU))
- -


a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the H40 central gateway ECU (network gateway ECU) connector.


c.

Measure the resistance according to the value(s) in the table below.

C422308C03
0.625,0.792 1.125,1.042 0.5,0.25 0.115,0.115 0.427,0.313 0.313,0.198 10 false *a 0.729,0.854 1.042,1.052 0.313,0.198 10 false H40
*a Front view of wire harness connector
(to Central Gateway ECU (Network Gateway ECU))
- -


Standard Resistance:
Diagnosis Bus Branch Lines (DLC3 - Central gateway ECU (network gateway ECU))
Terminal No. (Symbol) Terminal Description Condition Specified Condition
H40-16 (CA6H) - H40-17 (CA6L) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 1 MΩ or higher
H40-16 (CA6H) - H40-22 (GND) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H40-17 (CA6L) - H40-22 (GND) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H40-16 (CA6H) - H40-1 (BATT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
H40-17 (CA6L) - H40-1 (BATT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher

Bus 1 Main Lines
Terminal No. (Symbol) Terminal Description Condition Specified Condition
H40-28 (CA1H) - H40-27 (CA1L) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω
H40-28 (CA1H) - H40-22 (GND) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H40-27 (CA1L) - H40-22 (GND) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H40-28 (CA1H) - H40-1 (BATT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
H40-27 (CA1L) - H40-1 (BATT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher

Bus 2 Main Lines
Terminal No. (Symbol) Terminal Description Condition Specified Condition
H40-26 (CA4H) - H40-25 (CA4L) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω
H40-26 (CA4H) - H40-22 (GND) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H40-25 (CA4L) - H40-22 (GND) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H40-26 (CA4H) - H40-1 (BATT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
H40-25 (CA4L) - H40-1 (BATT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher

Bus 3 Main Lines
Terminal No. (Symbol) Terminal Description Condition Specified Condition
H40-30 (CA3H) - H40-29 (CA3L) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω
H40-30 (CA3H) - H40-22 (GND) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H40-29 (CA3L) - H40-22 (GND) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H40-30 (CA3H) - H40-1 (BATT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
H40-29 (CA3L) - H40-1 (BATT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher

Bus 4 Main Lines
Terminal No. (Symbol) Terminal Description Condition Specified Condition
H40-24 (CA2H) - H40-23 (CA2L) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω
H40-24 (CA2H) - H40-22 (GND) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H40-23 (CA2L) - H40-22 (GND) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H40-24 (CA2H) - H40-1 (BATT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
H40-23 (CA2L) - H40-1 (BATT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher

Bus 5 Main Lines
Terminal No. (Symbol) Terminal Description Condition Specified Condition
H40-7 (CA5H) - H40-8 (CA5L) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω
H40-7 (CA5H) - H40-22 (GND) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H40-8 (CA5L) - H40-22 (GND) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H40-7 (CA5H) - H40-1 (BATT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
H40-8 (CA5L) - H40-1 (BATT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher

Bus 6 Main Lines
Terminal No. (Symbol) Terminal Description Condition Specified Condition
H40-31 (CA7H) - H40-10 (CAVH) HIGH-level CAN bus line - HIGH-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal Below 1 Ω
H40-32 (CA7L) - H40-11 (CAVL) LOW-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal Below 1 Ω
H40-31 (CA7H) - H40-22 (GND) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H40-32 (CA7L) - H40-22 (GND) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H40-31 (CA7H) - H40-1 (BATT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
H40-32 (CA7L) - H40-1 (BATT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher

Bus 7 Main Lines
Terminal No. (Symbol) Terminal Description Condition Specified Condition
H40-5 (CA8H) - H40-6 (CA8L) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω
H40-5 (CA8H) - H40-22 (GND) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H40-6 (CA8L) - H40-22 (GND) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H40-5 (CA8H) - H40-1 (BATT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
H40-6 (CA8L) - H40-1 (BATT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




ECM


Refer to Terminals of ECU.

Click hereEngine / Hybrid System>M15A-FXE (ENGINE CONTROL)>SFI SYSTEM>TERMINALS OF ECM

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the A53 ECM connector.


c.
C328875C40
1.583,0.083 2.083,0.333 0.5,0.25 0.083,0.094 0.396,0.25 0.313,0.156 10 false *a 1.708,0.125 2.073,0.302 0.365,0.177 10 false A53
*a Front view of wire harness connector
(to ECM)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Bus 2 Main Lines
Terminal No. (Symbol) Terminal Description Condition Specified Condition
A53-13 (CANH) - A53-26 (CANL) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω
A53-13 (CANH) - A53-6 (E1) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A53-26 (CANL) - A53-6 (E1) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A53-13 (CANH) - A53-1 (BATT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
A53-26 (CANL) - A53-1 (BATT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher

Powertrain Local Bus Branch Lines
Terminal No. (Symbol) Terminal Description Condition Specified Condition
A53-12 (CAN+) - A53-25 (CAN-) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
A53-12 (CAN+) - A53-6 (E1) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A53-25 (CAN-) - A53-6 (E1) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A53-12 (CAN+) - A53-1 (BATT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
A53-25 (CAN-) - A53-1 (BATT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




RADIO AND DISPLAY RECEIVER ASSEMBLY (for Radio and Display Type)


Refer to Terminals of ECU.


a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the H80 radio and display receiver assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

C427752C04
3.729,0.76 4.135,1.031 0.406,0.271 0.229,0.781 0.635,1.052 0.406,0.271 0.385,0.188 0.698,0.385 0.313,0.198 10 false *a 3.729,0.156 4.042,0.354 0.313,0.198 10 false *1 3.844,0.802 4.156,1 0.313,0.198 10 false H3 0.302,0.823 0.615,1.021 0.313,0.198 10 false H80
*1 DLC3 - -
*a Front view of wire harness connector
(to Radio and Display Receiver Assembly)
- -


Standard Resistance:
Terminal No. (Symbol) Terminal Description Condition Specified Condition
H80-13 (CANH) - H80-14 (CANL) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
H80-13 (CANH) - H3-4 (CG) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H80-14 (CANL) - H3-4 (CG) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H80-13 (CANH) - H3-16 (BAT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
H80-14 (CANL) - H3-16 (BAT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




BRAKE BOOSTER WITH MASTER CYLINDER ASSEMBLY (for TMC Made)


Refer to Terminals of ECU.

Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ELECTRONICALLY CONTROLLED BRAKE SYSTEM (for HV Model TMC Made)>TERMINALS OF ECU

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the A38 Brake booster with master cylinder assembly connector.


c.
C378910C18
1.469,0.323 1.885,0.573 0.417,0.25 0.125,0.083 0.438,0.281 0.313,0.198 10 false *a 1.563,0.385 1.875,0.583 0.313,0.198 10 false A38
*a Front view of wire harness connector
(to Brake Booster with Master Cylinder Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Bus 4 Branch Lines
Terminal No. (Symbol) Terminal Description Condition Specified Condition
A38-43 (CA1H) - A38-42 (CA1L) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
A38-43 (CA1H) - A38-26 (GND1) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A38-42 (CA1L) - A38-26 (GND1) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A38-43 (CA1H) - A38-52 (BS) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
A38-42 (CA1L) - A38-52 (BS) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher

Powertrain Local Bus Main Lines
Terminal No. (Symbol) Terminal Description Condition Specified Condition
A38-30 (CA2H) - A38-29 (CA2L) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω
A38-30 (CA2H) - A38-26 (GND1) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A38-29 (CA2L) - A38-26 (GND1) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A38-30 (CA2H) - A38-52 (BS) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
A38-29 (CA2L) - A38-52 (BS) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




ELECTRIC BRAKE BOOSTER (BRAKE BOOSTER WITH MASTER CYLINDER ASSEMBLY) (for TMMF Made)


Refer to Terminals of ECU.

Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ELECTRONICALLY CONTROLLED BRAKE SYSTEM (for HV Model TMMF Made)>TERMINALS OF ECU

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the A34*1 or A35*2 electric brake booster (brake booster with master cylinder assembly) connector.

*1: for LHD

*2: for RHD



c.
C440174C01
0.833,0.167 1.333,0.417 0.5,0.25 1.917,0.167 2.417,0.417 0.5,0.25 1.406,0.188 1.75,0.417 0.344,0.229 12 false *A 2.5,0.188 2.802,0.49 0.302,0.302 12 false *B 0.167,0.125 0.479,0.281 0.313,0.156 10 false *a 0.948,0.208 1.323,0.427 0.375,0.219 10 false A34 2.042,0.198 2.417,0.417 0.375,0.219 10 false A35
*A for LHD
*B for RHD
*a Front view of wire harness connector
(to Electric Brake Booster (Brake Booster with Master Cylinder Assembly))


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Bus 4 Branch Lines (for LHD)
Terminal No. (Symbol) Terminal Description Condition Specified Condition
A34-18 (CA1H) - A34-10 (CA1L) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
A34-18 (CA1H) - A34-9 (GND) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A34-10 (CA1L) - A34-9 (GND) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A34-18 (CA1H) - A34-1 (+BS) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
A34-10 (CA1L) - A34-1 (+BS) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher

Bus 4 Branch Lines (for RHD)
Terminal No. (Symbol) Terminal Description Condition Specified Condition
A35-18 (CA1H) - A35-10 (CA1L) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
A35-18 (CA1H) - A35-9 (GND) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A35-10 (CA1L) - A35-9 (GND) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A35-18 (CA1H) - A35-1 (+BS) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
A35-10 (CA1L) - A35-1 (+BS) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher

Powertrain Local Bus Main Lines (for LHD)
Terminal No. (Symbol) Terminal Description Condition Specified Condition
A34-25 (CA2H) - A34-16 (CA2L) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
A34-25 (CA2H) - A34-9 (GND) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A34-16 (CA2L) - A34-9 (GND) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A34-25 (CA2H) - A34-1 (+BS) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
A34-16 (CA2L) - A34-1 (+BS) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher

Powertrain Local Bus Main Lines (for RHD)
Terminal No. (Symbol) Terminal Description Condition Specified Condition
A35-25 (CA2H) - A35-16 (CA2L) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
A35-25 (CA2H) - A35-9 (GND) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A35-16 (CA2L) - A35-9 (GND) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A35-25 (CA2H) - A35-1 (+BS) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
A35-16 (CA2L) - A35-1 (+BS) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




SKID CONTROL ECU (BRAKE ACTUATOR ASSEMBLY) (for TMMF Made)


Refer to Terminals of ECU.

Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ELECTRONICALLY CONTROLLED BRAKE SYSTEM (for HV Model TMMF Made)>TERMINALS OF ECU

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the A39 skid control ECU (brake actuator assembly) connector.


c.
C440175C01
1.5,0.167 2,0.417 0.5,0.25 0.115,0.094 0.427,0.25 0.313,0.156 10 false *a 1.604,0.208 1.938,0.448 0.333,0.24 10 false A39
*a Front view of wire harness connector
(to Skid Control ECU (Brake Actuator Assembly))


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Bus 4 Branch Lines
Terminal No. (Symbol) Terminal Description Condition Specified Condition
A39-5 (CANH) - A39-19 (CANL) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
A39-5 (CANH) - A39-46 (GND1) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A39-19 (CANL) - A39-46 (GND1) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A39-5 (CANH) - A39-30 (+BS) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
A39-19 (CANL) - A39-30 (+BS) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher

Powertrain Local Bus Main Lines
Terminal No. (Symbol) Terminal Description Condition Specified Condition
A39-11 (CA2H) - A39-25 (CA2L) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω
A39-11 (CA2H) - A39-46 (GND1) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A39-25 (CA2L) - A39-46 (GND1) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A39-11 (CA2H) - A39-30 (+BS) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
A39-25 (CA2L) - A39-30 (+BS) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




STEERING SENSOR


C358931C13
4.74,0.854 5.073,1.104 0.333,0.25 4.667,0.177 4.979,0.375 0.313,0.198 10 false *a 4.792,0.917 5.104,1.115 0.313,0.198 10 false H39
*a Component without harness connected
(Steering Sensor)
- -


a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the H39 steering sensor connector.


c.
C427527C04
0.552,0.927 0.958,1.229 0.406,0.302 0.146,0.156 0.458,0.354 0.313,0.198 10 false *a 0.635,0.979 0.948,1.177 0.313,0.198 10 false H39
*a Front view of wire harness connector
(to Steering Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Terminal No. (Symbol) Terminal Description Condition Specified Condition
H39-3 (CANH) - H39-8 (CANL) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
H39-3 (CANH) - H39-6 (ESS) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H39-8 (CANL) - H39-6 (ESS) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H39-3 (CANH) - H39-4 (BATT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
H39-8 (CANL) - H39-4 (BATT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




POWER STEERING ECU ASSEMBLY


Refer to Terminals of ECU.

Click hereSteering>POWER ASSIST SYSTEMS>POWER STEERING SYSTEM>TERMINALS OF ECU

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the H1 and H2 power steering ECU assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

C434461C01
1.094,0.792 1.594,1.042 0.5,0.25 3.948,0.792 4.448,1.042 0.5,0.25 0.104,0.115 0.417,0.313 0.313,0.198 10 false *a 1.26,0.833 1.573,1.031 0.313,0.198 10 false H1 4.115,0.833 4.427,1.031 0.313,0.198 10 false H2
*a Front view of wire harness connector
(to Power Steering ECU Assembly)
- -


Standard Resistance:
Terminal No. (Symbol) Terminal Description Condition Specified Condition
H1-7 (CANH) - H1-8 (CANL) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω
H1-7 (CANH) - H2-2 (PGND) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H1-8 (CANL) - H2-2 (PGND) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H1-7 (CANH) - H2-1 (PIG) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
H1-8 (CANL) - H2-1 (PIG) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




AIRBAG SENSOR ASSEMBLY


Refer to Terminals of ECU.

Click hereVehicle Interior>SUPPLEMENTAL RESTRAINT SYSTEMS>AIRBAG SYSTEM>TERMINALS OF ECU

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the H14 airbag sensor assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

C427534C04
0.792,0.781 1.177,1.042 0.385,0.26 3.594,0.771 3.979,1.031 0.385,0.26 0.385,0.208 0.698,0.406 0.313,0.198 10 false *a 3.406,0.208 3.719,0.406 0.313,0.198 10 false *1 3.698,0.813 4.01,1.01 0.313,0.198 10 false H3 0.854,0.823 1.167,1.021 0.313,0.198 10 false H14
*1 DLC3 - -
*a Front view of wire harness connector
(to Airbag Sensor Assembly)
- -


Standard Resistance:
Terminal No. (Symbol) Terminal Description Condition Specified Condition
H14-26 (CAFH) - H14-27 (CAFL) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
H14-26 (CAFH) - H14-33 (E1) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H14-27 (CAFL) - H14-33 (E1) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H14-26 (CAFH) - H3-16 (BAT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
H14-27 (CAFL) - H3-16 (BAT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




CERTIFICATION ECU (SMART KEY ECU ASSEMBLY) (w/ Entry and Start System)


Refer to Terminals of ECU.

Click hereVehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>ENTRY AND START SYSTEM (for Entry Function, HV Model)>TERMINALS OF ECU

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the H46 certification ECU (smart key ECU assembly) connector.


c.
C422313C02
1.563,0.125 2.063,0.375 0.5,0.25 0.115,0.115 0.427,0.313 0.313,0.198 10 false *a 1.688,0.167 2,0.365 0.313,0.198 10 false H46
*a Front view of wire harness connector
(to Certification ECU (Smart Key ECU Assembly))


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Terminal No. (Symbol) Terminal Description Condition Specified Condition
H46-1 (CANH) - H46-2 (CANL) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
H46-1 (CANH) - H46-29 (E) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H46-2 (CANL) - H46-29 (E) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H46-1 (CANH) - H46-6 (+B) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
H46-2 (CANL) - H46-6 (+B) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




METER MIRROR SUB-ASSEMBLY (w/ Headup Display System)


Refer to Terminals of ECU.

Click hereVehicle Interior>METER / GAUGE / DISPLAY>HEADUP DISPLAY SYSTEM>TERMINALS OF ECU

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the H61 meter mirror sub-assembly connector.


c.
C427758C05
1.5,0.177 1.896,0.458 0.396,0.281 0.146,0.125 0.458,0.323 0.313,0.198 10 false *a 1.573,0.229 1.885,0.427 0.313,0.198 10 false H61
*a Front view of wire harness connector
(to Meter Mirror Sub-assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Terminal No. (Symbol) Terminal Description Condition Specified Condition
H61-12 (MPX1) - H61-13 (MPX2) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
H61-12 (MPX1) - H61-4 (ES) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H61-13 (MPX2) - H61-4 (ES) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H61-12 (MPX1) - H61-2 (B) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
H61-13 (MPX2) - H61-2 (B) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




AIR CONDITIONING AMPLIFIER ASSEMBLY


Refer to Terminals of ECU.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for HV Model)>TERMINALS OF ECU

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the H24 air conditioning amplifier assembly connector.


c.
C422314C02
1.594,0.125 2.094,0.375 0.5,0.25 0.104,0.094 0.417,0.292 0.313,0.198 10 false *a 1.719,0.167 2.031,0.365 0.313,0.198 10 false H24
*a Front view of wire harness connector
(to Air Conditioning Amplifier Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Terminal No. (Symbol) Terminal Description Condition Specified Condition
H24-2 (CANH) - H24-1 (CANL) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
H24-2 (CANH) - H24-17 (GND) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H24-1 (CANL) - H24-17 (GND) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H24-2 (CANH) - H24-5 (B) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
H24-1 (CANL) - H24-5 (B) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)


Refer to Terminals of ECU.

Click hereVehicle Interior>LIGHTING (INT)>LIGHTING SYSTEM>TERMINALS OF ECU

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the H4 main body ECU (multiplex network body ECU) connector.


c.

Measure the resistance according to the value(s) in the table below.

C427524C04
0.354,0.792 0.729,1.01 0.375,0.219 3.625,0.792 4,1.01 0.375,0.219 0.198,0.104 0.51,0.302 0.313,0.198 10 false *a 3.771,0.167 4.083,0.365 0.313,0.198 10 false *1 0.458,0.823 0.771,1.021 0.313,0.198 10 false H4 3.729,0.823 4.042,1.021 0.313,0.198 10 false H3
*1 DLC3 - -
*a Front view of wire harness connector
(to Main Body ECU (Multiplex Network Body ECU))
- -


Standard Resistance:
Terminal No. (Symbol) Terminal Description Condition Specified Condition
H4-2 (CANH) - H4-1 (CANL) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω
H4-2 (CANH) - H3-4 (CG) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H4-1 (CANL) - H3-4 (CG) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H4-2 (CANH) - H3-16 (BAT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
H4-1 (CANL) - H3-16 (BAT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




COMBINATION METER ASSEMBLY


Refer to Terminals of ECU.

Click hereVehicle Interior>METER / GAUGE / DISPLAY>METER / GAUGE SYSTEM>TERMINALS OF ECU

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the H6 combination meter assembly connector.


c.
C406366C59
1.479,0.167 1.979,0.417 0.5,0.25 0.115,0.083 0.427,0.24 0.313,0.156 10 false *a 1.615,0.208 1.927,0.365 0.313,0.156 10 false H6
*a Front view of wire harness connector
(to Combination Meter Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Terminal No. (Symbol) Terminal Description Condition Specified Condition
H6-9 (CANH) - H6-25 (CANL) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω
H6-9 (CANH) - H6-23 (ES) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H6-25 (CANL) - H6-23 (ES) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H6-9 (CANH) - H6-22 (B) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
H6-25 (CANL) - H6-22 (B) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




CLEARANCE WARNING ECU ASSEMBLY (w/ TOYOTA Parking Assist-sensor System)


Refer to Terminals of ECU.

Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>PARKING ASSIST MONITOR SYSTEM>TERMINALS OF ECU

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the O60 clearance warning ECU assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

C427760C03
0.281,0.771 0.656,1.01 0.375,0.24 3.865,0.771 4.24,1.01 0.375,0.24 3.74,0.188 4.052,0.385 0.313,0.198 10 false *1 0.469,0.146 0.781,0.344 0.313,0.198 10 false *a 3.969,0.802 4.281,1 0.313,0.198 10 false H3 0.333,0.813 0.646,1.01 0.313,0.198 10 false O60
*1 DLC3 - -
*a Front view of wire harness connector
(to Clearance Warning ECU Assembly)
- -


Standard Resistance:
Terminal No. (Symbol) Terminal Description Condition Specified Condition
O60-17 (R1) - O60-18 (R2) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
O60-17 (R1) - O60-31 (E) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
O60-18 (R2) - O60-31 (E) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
O60-17 (R1) - H3-16 (BAT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
O60-18 (R2) - H3-16 (BAT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




FORWARD RECOGNITION CAMERA (w/ Toyota Safety Sense)


Refer to Terminals of ECU.

Click hereEngine / Hybrid System>CRUISE CONTROL>FRONT CAMERA SYSTEM>TERMINALS OF ECU

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the V10 forward recognition camera connector.


c.

Measure the resistance according to the value(s) in the table below.

C427754C03
3.76,0.75 4.156,1 0.396,0.25 0.844,0.76 1.24,1.01 0.396,0.25 0.917,0.802 1.229,1 0.313,0.198 10 false V10 0.417,0.208 0.729,0.406 0.313,0.198 10 false *a 3.646,0.26 3.958,0.458 0.313,0.198 10 false *1 3.865,0.781 4.177,0.979 0.313,0.198 10 false H3
*1 DLC3 - -
*a Front view of wire harness connector
(to Forward Recognition Camera)
- -


Standard Resistance:
Terminal No. (Symbol) Terminal Description Condition Specified Condition
V10-5 (CA1P) - V10-11 (CA1N) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
V10-5 (CA1P) - V10-10 (GND) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
V10-11 (CA1N) - V10-10 (GND) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
V10-5 (CA1P) - H3-16 (BAT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
V10-11 (CA1N) - H3-16 (BAT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




MILLIMETER WAVE RADAR SENSOR ASSEMBLY (w/ Toyota Safety Sense)


Refer to Terminals of ECU.

Click hereEngine / Hybrid System>CRUISE CONTROL>FRONT RADAR SENSOR SYSTEM>TERMINALS OF ECU

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the B8 millimeter wave radar sensor assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

C427755C03
0.729,0.792 1.115,1.042 0.385,0.25 3.719,0.823 4.146,1.063 0.427,0.24 3.594,0.177 3.906,0.375 0.313,0.198 10 false *1 0.708,0.135 1.021,0.333 0.313,0.198 10 false *a 0.833,0.833 1.146,1.031 0.313,0.198 10 false B8 3.844,0.865 4.156,1.063 0.313,0.198 10 false H3
*1 DLC3 - -
*a Front view of wire harness connector
(to Millimeter Wave Radar Sensor Assembly)
- -


Standard Resistance:
Terminal No. (Symbol) Terminal Description Condition Specified Condition
B8-3 (CA2H) - B8-2 (CA2L) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
B8-3 (CA2H) - B8-1 (SGND) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
B8-2 (CA2L) - B8-1 (SGND) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
B8-3 (CA2H) - H3-16 (BAT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
B8-2 (CA2L) - H3-16 (BAT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




BLIND SPOT MONITOR SENSOR LH (w/ Blind Spot Monitor System)


Refer to Terminals of ECU.

Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>BLIND SPOT MONITOR SYSTEM>TERMINALS OF ECU

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the T6*1 or O38*2 blind spot monitor sensor LH connector.

*1: for TMC Made

*2: for TMMF Made



c.

Measure the resistance according to the value(s) in the table below.

C427753C07
0.417,0.667 0.917,0.917 0.5,0.25 3.625,0.865 4.073,1.083 0.448,0.219 0.417,1 0.917,1.25 0.5,0.25 0.708,0.188 1.021,0.385 0.313,0.198 10 false *a 3.542,0.198 3.854,0.396 0.313,0.198 10 false *1 0.573,0.719 0.885,0.917 0.313,0.198 10 false T6 3.76,0.896 4.073,1.094 0.313,0.198 10 false H3 0.531,1.052 0.844,1.25 0.313,0.198 10 false O38 0.958,0.688 1.333,0.927 0.375,0.24 12 false *A 0.958,1.031 1.333,1.271 0.375,0.24 12 false *B
*A for TMC Made *B for TMMF Made
*1 DLC3 - -
*a Front view of wire harness connector
(to Blind Spot Monitor Sensor LH)
- -


Standard Resistance:
for TMC Made
Terminal No. (Symbol) Terminal Description Condition Specified Condition
T6-2 (CA1P) - T6-7 (CA1N) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
T6-2 (CA1P) - T6-10 (BLGD) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
T6-7 (CA1N) - T6-10 (BLGD) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
T6-2 (CA1P) - H3-16 (BAT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
T6-7 (CA1N) - H3-16 (BAT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher

for TMMF Made
Terminal No. (Symbol) Terminal Description Condition Specified Condition
O38-2 (CA1P) - O38-7 (CA1N) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
O38-2 (CA1P) - O38-10 (BLGD) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
O38-7 (CA1N) - O38-10 (BLGD) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
O38-2 (CA1P) - H3-16 (BAT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
O38-7 (CA1N) - H3-16 (BAT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




REAR TELEVISION CAMERA ASSEMBLY (w/ Parking Assist Monitor System)


Refer to Terminals of ECU.

Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>PARKING ASSIST MONITOR SYSTEM>TERMINALS OF ECU

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the Y2 rear television camera assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

C427757C03
0.635,0.75 1.031,1.031 0.396,0.281 3.719,0.792 4.115,1.073 0.396,0.281 0.5,0.219 0.813,0.417 0.313,0.198 10 false *a 3.458,0.25 3.771,0.448 0.313,0.198 10 false *1 3.823,0.844 4.135,1.042 0.313,0.198 10 false H3 0.74,0.802 1.146,1.01 0.406,0.208 10 false Y2
*1 DLC3 - -
*a Front view of wire harness connector
(to Rear Television Camera Assembly)
- -


Standard Resistance:
Terminal No. (Symbol) Terminal Description Condition Specified Condition
Y2-4 (CANH) - Y2-1 (CANL) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
Y2-4 (CANH) - H3-4 (CG) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
Y2-1 (CANL) - H3-4 (CG) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
Y2-4 (CANH) - H3-16 (BAT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
Y2-1 (CANL) - H3-16 (BAT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




HYBRID VEHICLE CONTROL ECU


Refer to Terminals of ECU.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>TERMINALS OF ECU

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the H44 hybrid vehicle control ECU connectors.


c.
C430869C02
1.635,0.198 2.052,0.448 0.417,0.25 0.156,0.135 0.469,0.333 0.313,0.198 10 false *a 1.719,0.271 2.177,0.469 0.458,0.198 10 false H44
*a Front view of wire harness connector
(to Hybrid Vehicle Control ECU)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Bus 2 Branch Lines
Terminal No. (Symbol) Terminal Description Condition Specified Condition
H44-9 (CA1H) - H44-22 (CA1L) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
H44-9 (CA1H) - H44-15 (E1) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H44-22 (CA1L) - H44-15 (E1) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H44-9 (CA1H) - H44-13 (BATT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
H44-22 (CA1L) - H44-13 (BATT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher

Powertrain Local Bus Main Lines
Terminal No. (Symbol) Terminal Description Condition Specified Condition
H44-24 (CA3P) - H44-11 (CA3N) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω
H44-24 (CA3P) - H44-15 (E1) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H44-11 (CA3N) - H44-15 (E1) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H44-24 (CA3P) - H44-13 (BATT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
H44-11 (CA3N) - H44-13 (BATT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




INVERTER WITH CONVERTER ASSEMBLY


Refer to Terminals of ECU.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>TERMINALS OF ECU

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the A56 inverter with converter assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

C434459C01
0.719,0.781 1.219,1.031 0.5,0.25 3.583,0.781 4.083,1.031 0.5,0.25 0.24,0.135 0.552,0.333 0.313,0.198 10 false *a 3.76,0.156 4.073,0.354 0.313,0.198 10 false *1 0.844,0.813 1.156,1.01 0.313,0.198 10 false A56 3.75,0.823 4.063,1.021 0.313,0.198 10 false H3
*1 DLC3 - -
*a Front view of wire harness connector
(to Inverter with Converter Assembly)
- -


Standard Resistance:
Terminal No. (Symbol) Terminal Description Condition Specified Condition
A56-1 (CANH) - A56-7 (CANL) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
A56-1 (CANH) - A56-24 (GND1) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A56-7 (CANL) - A56-24 (GND1) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A56-1 (CANH) - H3-16 (BAT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
A56-7 (CANL) - H3-16 (BAT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




BATTERY ECU ASSEMBLY


Refer to Terminals of ECU.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>TERMINALS OF ECU

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the O69 battery ECU assembly connector.


c.
C434460C01
0.198,1.042 0.698,1.292 0.5,0.25 0.156,0.135 0.469,0.333 0.313,0.198 10 false *a 0.313,1.073 0.635,1.271 0.323,0.198 10 false O69
*a Front view of wire harness connector
(to Battery ECU Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Terminal No. (Symbol) Terminal Description Condition Specified Condition
O69-6 (CA2H) - O69-1 (CA2L) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
O69-6 (CA2H) - O69-4 (GND) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
O69-1 (CA2L) - O69-4 (GND) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
O69-6 (CA2H) - O69-5 (AM) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
O69-1 (CA2L) - O69-5 (AM) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




VEHICLE APPROACHING SPEAKER CONTROLLER (w/ Acoustic Vehicle Alerting System)


Refer to Terminals of ECU.

Click hereVehicle Exterior>ACOUSTIC VEHICLE ALERTING SYSTEM>ACOUSTIC VEHICLE ALERTING SYSTEM>TERMINALS OF ECU

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the A69 vehicle approaching speaker controller connector.


c.

Measure the resistance according to the value(s) in the table below.

C427764C04
0.667,0.833 1.167,1.083 0.5,0.25 3.667,0.833 4.167,1.083 0.5,0.25 0.542,0.229 0.854,0.427 0.313,0.198 10 false *a 3.406,0.198 3.719,0.396 0.313,0.198 10 false *1 0.781,0.875 1.198,1.094 0.417,0.219 10 false A69 3.833,0.875 4.25,1.094 0.417,0.219 10 false H3
*1 DLC3 - -
*a Front view of wire harness connector
(to Vehicle Approaching Speaker Controller)
- -


Standard Resistance:
Terminal No. (Symbol) Terminal Description Condition Specified Condition
A69-3 (CANH) - A69-4 (CANL) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
A69-3 (CANH) - A69-6 (GND) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A69-4 (CANL) - A69-6 (GND) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
A69-3 (CANH) - H3-16 (BAT) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
A69-4 (CANL) - H3-16 (BAT) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




TIRE PRESSURE WARNING ECU AND RECEIVER (w/ Tire Pressure Warning System)


Refer to Terminals of ECU.

Click hereSuspension>TIRE PRESSURE MONITORING>TIRE PRESSURE WARNING SYSTEM>TERMINALS OF ECU

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the O33*1 or O34*2 tire pressure warning ECU and receiver connector.

*1: w/ Entry and Start System

*2: w/o Entry and Start System



c.
C427521C12
0.333,1 0.833,1.25 0.5,0.25 0.333,1.354 0.833,1.604 0.5,0.25 0.146,0.156 0.458,0.354 0.313,0.198 10 false *a 0.448,1.031 0.792,1.292 0.344,0.26 10 false O33 0.865,1.021 1.156,1.281 0.292,0.26 12 false *A 0.448,1.396 0.792,1.656 0.344,0.26 10 false O34 0.875,1.396 1.198,1.708 0.323,0.313 12 false *B
*A w/ Entry and Start System
*B w/o Entry and Start System
*a Front view of wire harness connector
(to Tire Pressure Warning ECU and Receiver)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
w/ Entry and Start System
Terminal No. (Symbol) Terminal Description Condition Specified Condition
O33-9 (CANH) - O33-10 (CANL) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
O33-9 (CANH) - O33-12 (GND) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
O33-10 (CANL) - O33-12 (GND) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
O33-9 (CANH) - O33-7 (+B) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
O33-10 (CANL) - O33-7 (+B) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher

w/o Entry and Start System
Terminal No. (Symbol) Terminal Description Condition Specified Condition
O34-9 (CANH) - O34-10 (CANL) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
O34-9 (CANH) - O34-12 (GND) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
O34-10 (CANL) - O34-12 (GND) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
O34-9 (CANH) - O34-7 (+B) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
O34-10 (CANL) - O34-7 (+B) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher




TELEPHONE TRANSCEIVER ASSEMBLY (w/ Telematics Transceiver)


Refer to Terminals of ECU.

Click hereAudio / Visual / Telematics>TELEMATICS>TELEMATICS SYSTEM (for eCall)>TERMINALS OF ECU

a.

Disconnect the cable from the negative (-) auxiliary battery terminal.


b.

Disconnect the H85 telephone transceiver assembly connector.


c.
C427756C16
1.427,0.24 1.927,0.49 0.5,0.25 0.115,0.073 0.427,0.271 0.313,0.198 10 false *a 1.552,0.271 1.99,0.479 0.438,0.208 10 false H85
*a Front view of wire harness connector
(to Telephone Transceiver Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Terminal No. (Symbol) Terminal Description Condition Specified Condition
H85-25 (CANP) - H85-26 (CANN) HIGH-level CAN bus line - LOW-level CAN bus line Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω
H85-25 (CANP) - H85-20 (E) HIGH-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H85-26 (CANN) - H85-20 (E) LOW-level CAN bus line - Ground Cable disconnected from negative (-) auxiliary battery terminal 200 Ω or higher
H85-25 (CANP) - H85-1 (+B) HIGH-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher
H85-26 (CANN) - H85-1 (+B) LOW-level CAN bus line - Auxiliary battery positive (+) Cable disconnected from negative (-) auxiliary battery terminal 6 kΩ or higher