This DTC is stored if the amount of refrigerant in the air conditioning system is insufficient.
The air conditioning amplifier assembly receives the ambient temperature signal, refrigerant pressure signal, etc. from various sensors.
Based on these signals, the air conditioning amplifier assembly detects the amount of refrigerant.
If the amount of refrigerant is insufficient, the A/C switch indicator will turn off and the air conditioning system will stop operating.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| P05347A | Refrigerant Gas Fluid Leak or Seal Failure | Diagnosis Condition:
Refrigerant shortage check is satisfied in normal operation Malfunction Status: Amount of refrigerant is insufficient Detection Time: Air conditioning system operating 15 minutes or more |
·
Refrigerant line ·
Cooler expansion valve ·
Air conditioner pressure sensor ·
Harness or connector ·
Air conditioning amplifier assembly |
Memorized |
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| for HFC-134a(R134a) | A |
| for HFO-1234yf(R1234yf) | B |
A
B
Pre-procedure1
Install a manifold gauge set.
Read the manifold gauge set with the following conditions met.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
Procedure1
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -32.768 MPaG
Max.: 32.767 MPaG |
Actual refrigerant pressure displayed | ·
Refrigerant line (gas leak etc.) ·
Air conditioner pressure sensor circuit malfunction |
| Tester Display |
|---|
| Regulator Pressure Sensor |
Compare the values displayed in the Data List and on the manifold gauge set.
| Result | Proceed to |
|---|---|
| The values displayed in the Data List and on the manifold gauge set match | A |
| The values displayed in the Data List and on the manifold gauge set does not match | B |
Post-procedure1
None
A
Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT (for HFC-134a(R134a))>ON-VEHICLE INSPECTION
B
Pre-procedure1
Install a manifold gauge set.
Read the manifold gauge set with the following conditions met.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
Procedure1
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -32.768 MPaG
Max.: 32.767 MPaG |
Actual refrigerant pressure displayed | ·
Refrigerant line (gas leak etc.) ·
Air conditioner pressure sensor circuit malfunction |
| Tester Display |
|---|
| Regulator Pressure Sensor |
Compare the values displayed in the Data List and on the manifold gauge set.
| Result | Proceed to |
|---|---|
| The values displayed in the Data List and on the manifold gauge set match | A |
| The values displayed in the Data List and on the manifold gauge set does not match | B |
Post-procedure1
None
A
B
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| except G16E-GTS | A |
| for G16E-GTS | B |
A
B
Pre-procedure1
Disconnect the A51 air conditioner pressure sensor connector.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A51-3 (+) - Body ground | Ignition switch ON | 4.75 to 5.25 V |
Post-procedure1
None
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A51-1 (-) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Disconnect the H25 air conditioning amplifier assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A51-2 (PR) - H25-6 (PRE) | Always | Below 1 Ω |
| A51-2 (PR) or H25-6 (PRE) - Other terminals and body ground | Always | 10 kΩ or higher |
Post-procedure1
None
| Proceed to |
|---|
| OK |
| NG |
OK
NG
If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.61 V), a fail-safe function will stop compressor operation. In this case, make sure to measure the voltage before the fail-safe function operates.
It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.
Pre-procedure1
Connect the air conditioning amplifier assembly connector.
Measure the voltage with the following conditions met.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
Procedure1
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H25-6 (PRE) - Body ground | A/C switch on
(Compressor operating) |
0.62 to 4.73 V*1 |
*1: While sensor voltage is 5 V.
When the ambient air temperature is low (below -1.5°C (29.3°F)), the compressor will be stopped, due to inputs of the thermistor assembly and No. 1 cooler thermistor, to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
The voltage value changes.
Post-procedure1
None
| Proceed to |
|---|
| OK |
| NG |
OK
NG
If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.61 V), a fail-safe function will stop compressor operation. In this case, make sure to measure the voltage before the fail-safe function operates.
It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.
Pre-procedure1
Measure the voltage with the following conditions met.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
Procedure1
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -32.768 MPaG
Max.: 32.767 MPaG |
Actual refrigerant pressure displayed | ·
Refrigerant line (gas leak etc.) ·
Air conditioner pressure sensor circuit malfunction |
| Tester Display |
|---|
| Regulator Pressure Sensor |
When the ambient air temperature is low (below -1.5°C (29.3°F)), the compressor will be stopped, due to inputs of the thermistor assembly and No. 1 cooler thermistor, to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
The value displayed in the Data List changes.
Post-procedure1
None
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
NG
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER (except G16E-GTS)>REMOVAL
Pre-procedure1
Disconnect the H25 air conditioning amplifier assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A51-1 (-) - H25-15 (SG-4) | Always | Below 1 Ω |
| A51-1 (-) or H25-15 (SG-4) - Other terminals and body ground | Always | 10 kΩ or higher |
Post-procedure1
None
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER (except G16E-GTS)>REMOVAL
NG
Pre-procedure1
Disconnect the H25 air conditioning amplifier assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A51-3 (+) - H25-11 (S5-3) | Always | Below 1 Ω |
| A51-3 (+) or H25-11 (S5-3) - Other terminals and body ground | Always | 10 kΩ or higher |
Post-procedure1
None
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER (except G16E-GTS)>REMOVAL
NG
Pre-procedure1
Disconnect the A51 air conditioner pressure sensor connector.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A51-3 (+) - Body ground | Ignition switch ON | 4.75 to 5.25 V |
Post-procedure1
None
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A51-1 (-) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Disconnect the H25 air conditioning amplifier assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A51-2 (PR) - H25-6 (PRE) | Always | Below 1 Ω |
| A51-2 (PR) or H25-6 (PRE) - Other terminals and body ground | Always | 10 kΩ or higher |
Post-procedure1
None
| Proceed to |
|---|
| OK |
| NG |
OK
NG
If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.61 V), a fail-safe function will stop compressor operation. In this case, make sure to measure the voltage before the fail-safe function operates.
It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.
Pre-procedure1
Connect the air conditioning amplifier assembly connector.
Measure the voltage with the following conditions met.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
Procedure1
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H25-6 (PRE) - Body ground | A/C switch on
(Compressor operating) |
0.62 to 4.73 V*1 |
*1: While sensor voltage is 5 V.
When the ambient air temperature is low (below -1.5°C (29.3°F)), the compressor will be stopped, due to inputs of the thermistor assembly and No. 1 cooler thermistor, to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
The voltage value changes.
Post-procedure1
None
| Proceed to |
|---|
| OK |
| NG |
OK
NG
If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.61 V), a fail-safe function will stop compressor operation. In this case, make sure to measure the voltage before the fail-safe function operates.
It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.
Pre-procedure1
Measure the voltage with the following conditions met.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
Procedure1
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -32.768 MPaG
Max.: 32.767 MPaG |
Actual refrigerant pressure displayed | ·
Refrigerant line (gas leak etc.) ·
Air conditioner pressure sensor circuit malfunction |
| Tester Display |
|---|
| Regulator Pressure Sensor |
When the ambient air temperature is low (below -1.5°C (29.3°F)), the compressor will be stopped, due to inputs of the thermistor assembly and No. 1 cooler thermistor, to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
The value displayed in the Data List changes.
Post-procedure1
None
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
NG
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER (for G16E-GTS)>REMOVAL
Pre-procedure1
Disconnect the H25 air conditioning amplifier assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A51-1 (-) - H25-15 (SG-4) | Always | Below 1 Ω |
| A51-1 (-) or H25-15 (SG-4) - Other terminals and body ground | Always | 10 kΩ or higher |
Post-procedure1
None
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER (for G16E-GTS)>REMOVAL
NG
Pre-procedure1
Disconnect the H25 air conditioning amplifier assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A51-3 (+) - H25-11 (S5-3) | Always | Below 1 Ω |
| A51-3 (+) or H25-11 (S5-3) - Other terminals and body ground | Always | 10 kΩ or higher |
Post-procedure1
None
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER (for G16E-GTS)>REMOVAL
NG