Home › Power Source / Network › G16E-GTS (BATTERY / CHARGING) › CHARGING SYSTEM › from 2020.09
RM36W0E _57 Power Source / Network _095208 G16E-GTS BATTERY / CHARGING _0447332 CHARGING SYSTEM C

G16E-GTS BATTERY / CHARGING  CHARGING SYSTEM  P062049  Generator Control Circuit Internal Electronic Failure  


DESCRIPTION

The alternator performs self-diagnosis of its internal circuits to detect malfunctions (open or short circuits).

The ECM receives the result via LIN communication and stores a DTC.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Note
P062049 Generator Control Circuit Internal Electronic Failure All of the following conditions are met (1 trip detection logic):
·

Ignition switch ON.

·

Except during engine cranking.

·

Auxiliary battery voltage is 10.5 V or higher.

·

No malfunction in the LIN communication system.

·

Open or short in EXC circuit, or abnormal waveform for PH circuit.


Generator assembly Comes on SAE Code: P0620

WIRING DIAGRAM

A475123E04
3.135,1.25 3.594,1.448 0.458,0.198 10 false O68 3.146,1.406 4.344,1.792 1.198,0.385 10 false Battery State Sensor Assembly 5.792,2.74 6.25,2.938 0.458,0.198 10 false ECM 4.24,4.292 5.135,4.521 0.896,0.229 10 false IC Regulator 4.01,5.344 5.438,5.563 1.427,0.219 10 false Generator Assembly 1.031,0.448 1.792,0.646 0.76,0.198 10 false R/B BATT 2.042,0.448 3,0.646 0.958,0.198 10 false BATT-S NO. 1 0.792,1.146 1.927,1.333 1.135,0.188 10 false INP STD NO. 1-3 2.073,1.156 2.979,1.354 0.906,0.198 10 false ECU-B NO. 2 2.385,2.552 2.781,2.74 0.396,0.188 10 false ALT 0.563,3.146 1.542,3.333 0.979,0.188 10 false ENG 3.188,0.323 3.5,0.521 0.313,0.198 10 false +B 3.198,1 3.813,1.198 0.615,0.198 10 false RBAT 3.875,0.656 4.333,0.854 0.458,0.198 10 false LIN 5.823,0.646 6.281,0.844 0.458,0.198 10 false LIN 5.833,1.823 6.146,2.021 0.313,0.198 10 false E1 4.729,3.302 5.188,3.5 0.458,0.198 10 false LIN 4.51,3.604 4.969,3.802 0.458,0.198 10 false LIN 3.469,3.302 3.625,3.5 0.156,0.198 10 false B 3.854,3.594 4.01,3.792 0.156,0.198 10 false B 3.854,4.219 4.01,4.417 0.156,0.198 10 false P 3.854,4.76 4.01,4.958 0.156,0.198 10 false F 3.844,5.01 4,5.208 0.156,0.198 10 false E 3.25,3.083 3.865,3.281 0.615,0.198 10 false D107 4.49,3.083 4.948,3.281 0.458,0.198 10 false D53 3.667,3.083 3.823,3.281 0.156,0.198 10 false 1 4.844,3.083 5,3.281 0.156,0.198 10 false 2 3,0.229 3.156,0.427 0.156,0.198 10 false 3 3.01,0.938 3.167,1.135 0.156,0.198 10 false 1 4.188,0.49 4.344,0.688 0.156,0.198 10 false 2 5.417,0.656 6.031,0.854 0.615,0.198 10 false D104 5.417,1.813 6.031,2.01 0.615,0.198 10 false A106 5.5,0.427 5.813,0.625 0.313,0.198 10 false 62 5.5,1.594 5.813,1.792 0.313,0.198 10 false 10 0.677,4.01 1.26,4.438 0.583,0.427 10 false Auxiliary Battery 0.698,6.427 2.375,6.625 1.677,0.198 10 false : LIN Communication Line

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.


PROCEDURE

1.CHARGING CIRCUIT WITHOUT LOAD

OK

2.CHARGING CIRCUIT WITH LOAD

NG

REPAIR OR REPLACE GENERATOR ASSEMBLY