G16E-GTS BATTERY / CHARGING  GENERATOR  REMOVAL  


CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed, installed, or replaced during the generator with regulator assembly removal/installation are shown below.

Necessary Procedure After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedures Effect/Inoperative Function when Necessary Procedure not Performed Link
Auxiliary battery terminal is disconnected/reconnected Memorize steering angle neutral point Parking assist monitor system (Click here)

HINT:

When the cable is disconnected / reconnected to the auxiliary battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.

·

Learning completes when vehicle is driven

Effect/Inoperative Function When Necessary Procedures are not Performed Necessary Procedures Link
Lane tracing assist system Drive the vehicle straight ahead at 35 km/h (22 mph) or more for 5 seconds or more. (Click here)
Pre-collision system
Stop and start system Drive the vehicle until stop and start control is permitted (approximately 5 to 60 minutes) (Click here)

·

Learning completes when vehicle is operated normally

Effect/Inoperative Function When Necessary Procedures are not Performed Necessary Procedures Link
Power door lock control system
·

Back door opener


Perform door unlock operation with door control switch or electrical key transmitter sub-assembly switch. (Click here)
Air conditioning system After the ignition switch is turned to ON, the servo motor standard position is recognized. -



PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY


Hide 2.DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL

Hide 16361A 3.REMOVE V-RIBBED BELT

Hide 27020 4.REMOVE GENERATOR WITH REGULATOR ASSEMBLY

a.
A474199

Disengage the clamp.


b.

Disconnect the 3 connectors.


c.

Open the terminal cap.


d.

Remove the nut and disconnect the wire harness from terminal B.


e.
A478833

Remove the 2 nuts and generator splash guard cover assembly.


f.
A478834

Remove the bolt.


g.

Using an E8 "TORX" socket wrench, remove the 2 stud bolts and generator with regulator assembly.