Refer to DTC C13807E.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | DTC Output from |
|---|---|---|---|---|
| C13807F | Stop Lamp Relay Actuator Stuck Off | ACC terminal is ON and STP2 terminal is OFF for 2 seconds or more. | ·
Wire harness or connector ·
Stop light switch assembly ·
Skid control ECU (brake actuator assembly) ·
Rear combination light assembly LH ·
Rear combination light assembly RH ·
Center stop light assembly |
Brake |
Inspect the fuses for circuits related to this system before performing the following procedure.
After replacing the skid control ECU (brake actuator assembly), perform yaw rate and acceleration sensor zero point calibration and store system information memorization.
When DTC P057111 and/or P057112 are output together with DTC C13807F, inspect and repair the trouble areas indicated by DTC P057111 and/or P057112 first.
Perform the stop light control relay (stop light switch assembly) Active Test, and confirm that the stop lights illuminate and turn off and the value of "Stop Light SW", "Stop Light Relay" and "STPO" changes.
| Tester Display | Measurement Item | Control Range | Restrict Condition | Diagnostic Note |
|---|---|---|---|---|
| Stop Lamp Relay | Stop light control relay (stop light switch assembly) | OFF / ON | Vehicle condition: Vehicle stopped
|
With the brake pedal released, check that the stop lights illuminate and value of "Stop Light Relay" on the GTS changes to ON when "Stop Lamp Relay" is ON |
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Stop Light SW | Stop light switch assembly status
(STP or STP2 terminal input) |
OFF / ON | OFF: Brake pedal released
ON: Brake pedal depressed |
|
| Stop Light Relay | Stop light control relay (stop light switch assembly) status
(STP terminal input) |
OFF / ON | OFF: Stop light control relay (stop light switch assembly) off and brake pedal released
ON: Stop light control relay (stop light switch assembly) on or brake pedal depressed |
|
| STPO | Stop light control relay (stop light switch assembly) status
(STPO terminal output) |
OFF / ON | OFF: Stop light control relay (stop light switch assembly) off (Stop light off)
ON: Stop light control relay (stop light switch assembly) on (Stop light on) |
|
| Active Test Display |
|---|
| Stop Lamp Relay |
| Data List Display |
|---|
| Stop Light SW |
| Stop Light Relay |
| STPO |
Turn the ignition switch off.
| Data List Status | Stop Light Illumination Status | Proceed to | ||
|---|---|---|---|---|
| Stop Light SW | Stop Light Relay | STPO | ||
| OFF | OFF | ON | Not illuminated | A |
| OFF | OFF | ON | Illuminated | B |
| ON | ON | ON | Illuminated | C |
A
B
C
Pre-procedure1
Make sure that there is no looseness at the locking part and the connecting part of the connectors.
The connector is securely connected.
Disconnect the A37 skid control ECU (brake actuator assembly) connector.
Check both the connector case and the terminals for deformation and corrosion.
No deformation or corrosion.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A37-28 (STPO) - Body ground | Always | 11 to 14 V |
Post-procedure1
None
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A37-2 (STP) - Body ground | Stop light switch assembly on
(Brake pedal depressed) |
11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
for LHD: Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>BRAKE ACTUATOR (for Gasoline Model TMMF, TMMCZ Made LHD)>REMOVAL
for RHD: Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>BRAKE ACTUATOR (for Gasoline Model TMMF Made RHD)>REMOVAL
NG
Check that there is no short to ground in the STP circuit (wire harnesses, connectors and stop lights).
There is no short to ground.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Make sure that there is no looseness at the locking part and the connecting part of the connectors.
The connector is securely connected.
Disconnect the A63 stop light switch assembly connector.
Check both the connector case and the terminals for deformation and corrosion.
No deformation or corrosion.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A63-1 (OUT) - A37-12 (STP2) | Always | Below 1 Ω |
Post-procedure1
None
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
| *a | Component with harness connected
(Stop Light Switch Assembly) |
Make sure that there is no looseness at the locking part and the connecting part of the connectors.
The connector is securely connected.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A63-4 (ACC) - Body ground | Always | 11 to 14 V |
Post-procedure1
None
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Make sure that there is no looseness at the locking part and the connecting part of the connectors.
The connector is securely connected.
Disconnect the A37 skid control ECU (brake actuator assembly) connector.
Check both the connector case and the terminals for deformation and corrosion.
No deformation or corrosion.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A37-2 (STP) - Body ground | Stop light switch assembly on
(Brake pedal depressed) |
11 to 14 V |
Post-procedure1
None
| Proceed to |
|---|
| OK |
| NG |
OK
for LHD: Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>BRAKE ACTUATOR (for Gasoline Model TMMF, TMMCZ Made LHD)>REMOVAL
for RHD: Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>BRAKE ACTUATOR (for Gasoline Model TMMF Made RHD)>REMOVAL
NG
Pre-procedure1
Make sure that there is no looseness at the locking part and the connecting part of the connectors.
The connector is securely connected.
Disconnect the A37 skid control ECU (brake actuator assembly) connector.
Check both the connector case and the terminals for deformation and corrosion.
No deformation or corrosion.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A37-12 (STP2) - Body ground | Stop light switch assembly off
(Brake pedal released) |
Below 1.5 V |
Post-procedure1
None
| Proceed to |
|---|
| OK |
| NG |
OK
for LHD: Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>BRAKE ACTUATOR (for Gasoline Model TMMF, TMMCZ Made LHD)>REMOVAL
for RHD: Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>BRAKE ACTUATOR (for Gasoline Model TMMF Made RHD)>REMOVAL
NG
Pre-procedure1
Make sure that there is no looseness at the locking part and the connecting part of the connectors.
The connector is securely connected.
Disconnect the A63 stop light switch assembly connector.
Check both the connector case and the terminals for deformation and corrosion.
No deformation or corrosion.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A37-12 (STP2) - Body ground | Always | Below 1.5 V |
Post-procedure1
None
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check that there is no short to +B in the STP2 circuit (wire harnesses, connectors and ECUs).
No short to +B.
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
NG