2005-2008 Yaris · Service Manual ENGINE

P0130 Oxygen (A/F) Sensor Circuit (Bank 1 Sensor 1)

Diagnostic trouble codes · Vehicles built from Aug 2005

Also covers:

DESCRIPTION

In order to obtain a high purification rate for the carbon monoxide (CO), hydrocarbon (HC) and nitrogen oxide (NOx) components in the exhaust gas, a Three-Way Catalytic Converter (TWC) is used. For the most efficient use of the TWC, the air-fuel ratio must be precisely controlled so that it is always close to the stoichiometric air-fuel ratio. The heated oxygen sensor has the characteristic whereby its output voltage changes suddenly in the vicinity of the stoichiometric air-fuel ratio. This is used to detect the oxygen concentration in the exhaust gas and provide the ECM with feedback to control the air-fuel ratio. When the air-fuel ratio becomes lean, the oxygen concentration in the exhaust gas increases. The heated oxygen sensor informs the ECM of the lean condition (low voltage, i.e. less than 0.45 V). When the air-fuel ratio is richer than the stoichiometric air-fuel level, the oxygen concentration in the exhaust gas is reduced. And the heated oxygen sensor informs the ECM of the rich condition (high voltage, i.e. more than 0.45 V). The ECM judges, using the voltage output of the heated oxygen sensor, whether the air-fuel ratio is rich or lean and controls the injection time accordingly. If a malfunction of the heated oxygen sensor causes an output of abnormal voltage, the ECM is unable to perform accurate air-fuel ratio control. The heated oxygen sensor includes a heater which heats the zirconia element. The heater is controlled by the ECM. When the intake air volume is low (the temperature of the exhaust gas is low), a current flows to the heater in order to heat the sensor for accurate oxygen concentration detection.
G035432E01
DTC No.
DTC Detection Condition
Trouble Area
P0130
Both conditions below continue for 20 seconds during air-fuel ratio feedback control (3 trip detection logic).
  1. Heated oxygen sensor (sensor 1) output voltage is less than 0.4 V.
  2. Heated oxygen sensor (sensor 2) output voltage is 0.5 V or more.
  1. Short to GND in heated oxygen sensor (sensor 1) circuit
  2. Heated oxygen sensor (sensor 1)
  3. ECM
P0130
Heated oxygen sensor (sensor 1) output voltage is less than 0.06 V within 1 second after engine was started with engine coolant temperature 42°C (107°F) or less (last engine operation was stopped after warm-up). (3 trip detection logic)
  1. Short to GND in heated oxygen sensor (sensor 1) circuit
  2. Heated oxygen sensor (sensor 1)
  3. ECM
P0130
Both conditions below continue for 20 seconds during air-fuel ratio feedback control (3 trip detection logic).
  1. Heated oxygen sensor (sensor 2) output voltage is less than 0.1V.
  2. Heated oxygen sensor (sensor 1) output voltage is between 0.6 V and 1.5 V.
  1. Heated oxygen sensor (sensor 1)
P0134
Heated oxygen sensor (sensor 1) output voltage is between 0.4 V and 0.6 V for 20 seconds or more (3 trip detection logic).
  1. Open in heated oxygen sensor (sensor 1) circuit
  2. Heated oxygen sensor (sensor 1)
P0134
All of the conditions below are met (3 trip detection logic).
  1. Heated oxygen sensor (sensor 1) output voltage is 0.2 V or more.
  2. Heated oxygen sensor (sensor 2) output voltage is 0.2 V or more.
  3. Fuel cut is performed for 3 seconds or more.
  1. Open or short in heated oxygen sensor (sensor 1) circuit
  2. Heated oxygen sensor (sensor 1)
  3. ECM
P0134
ECM determines that internal resistance of heated oxygen sensor (sensor 1) is 20 kΩ or more (3 trip detection logic).
  1. Open in heated oxygen sensor (sensor 1) circuit
  2. Heated oxygen sensor (sensor 1)

HINT:
  1. The internal resistance of the heated oxygen sensor (sensor 1) cannot be measured using a tester.
  2. Sensor 1 refers to the sensor near the engine assembly.
  3. The output voltage of the heated oxygen sensor and the short-term fuel trim value can be read using the intelligent tester.


WIRING DIAGRAM

A109127E01

CONFIRMATION DRIVING PATTERN

CAUTION:
Strictly observe traffic laws when performing the confirmation driving pattern.

  1. DTC P0130 is detected when the vehicle is driven with a city driving pattern at an average vehicle speed of approximately 50 km/h (31 mph) for approximately 30 minutes.
  2. DTC P0134 is detected when the vehicle is driven with a city driving pattern at an average vehicle speed of approximately 50 km/h (31 mph) for approximately 30 minutes.

INSPECTION PROCEDURE

NOTICE:
Perform electronic throttle learning after replacing the ECM (Click here).

HINT:
Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.


1. READ VALUE OF HEATED OXYGEN SENSOR
  1. Connect the intelligent tester to the DLC3.

  1. Start the engine and turn the intelligent tester ON.

  1. Select the following menu items: Powertrain / Engine and ECT / Data List / O2S B1 S1.

  1. Warm up the heated oxygen sensor at an engine speed of 2,500 rpm for approximately 90 seconds.

  1. Read the output voltage of the heated oxygen sensor during engine idling.

    Standard:
    Fluctuates between less than 0.4 V and more than 0.6 V (see the following figure).

    A099192E01



OK
Go to step 3
NG


2. CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR (SENSOR 1) - ECM)
A120336E01
A116151E01
  1. Disconnect the heated oxygen sensor (sensor 1) connector.

  1. Disconnect the ECM connector.

  1. Check the resistance.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    OX1A (C36-3) - OX1A (C33-18)
    Below 1 Ω
    HT1A (C36-1) - HT1A (C33-41)
    Below 1 Ω
    E1 (C36-4) - E11 (C33-17)
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    OX1A (C36-3) or OX1A (C33-18) - Body ground
    10 kΩ or higher
    HT1A (C36-1) or HT1A (C33-41) - Body ground
    10 kΩ or higher

  1. Reconnect the heated oxygen sensor (sensor 1) connector.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE HEATED OXYGEN SENSOR (SENSOR 1)

Go to step 5

3. PERFORM CONFIRMATION DRIVING PATTERN

HINT:
Clear all DTCs prior to performing the confirmation driving pattern.


NEXT


4. CHECK WHETHER DTC OUTPUT RECURS (DTC P0130 OR P0134)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG) and turn the tester ON.

  1. Select the following menu items: Powertrain / Engine and ECT / DTC / Pending.

  1. Read DTCs.

    Result:
    Display (DTC Output)
    Proceed To
    P0130 and/or P0134
    A
    No DTC output
    B



B
GO TO CHECK FOR INTERMITTENT PROBLEMS
A


5. REPLACE HEATED OXYGEN SENSOR (SENSOR 1)

NEXT


6. PERFORM CONFIRMATION DRIVING PATTERN

HINT:
Clear all DTCs prior to performing the confirmation driving pattern.


NEXT


7. CHECK WHETHER DTC OUTPUT RECURS (DTC P0130 OR P0134)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG) and turn the tester ON.

  1. Select the following menu items: Powertrain / Engine and ECT / DTC / Pending.

  1. Read DTCs.

    Result:
    Display (DTC Output)
    Proceed To
    P0130 and/or P0134
    A
    No DTC output
    B



B
END
A

REPLACE ECM


← P0125 Insufficient Coolant Temperature for Closed Loop Fuel Control (from Aug 2005)P0132 Oxygen Sensor Circuit High Voltage Bank1 Sensor1 (from Aug 2005) →