P0010 Camshaft Position "A" Actuator Circuit (Bank 1)
Diagnostic trouble codes · Vehicles built from Aug 2005
DESCRIPTION
The Variable Valve Timing (VVT) system includes the ECM, Camshaft Timing Oil Control Valve (OCV) and VVT controller. The ECM sends a target "duty-cycle" control signal to the OCV. This control signal, applied to the OCV, regulates the oil pressure supplied to the VVT controller. Camshaft timing control is performed based on engine operating conditions such as intake air volume, throttle position and engine coolant temperature.The ECM controls the OCV based on the signals from several sensors. The VVT controller regulates the intake camshaft angle using oil pressure through the OCV. As a result, the relative positions of the camshaft and crankshaft are optimized, engine torque and fuel economy improve, and the exhaust emissions drop. The ECM detects actual valve timing using signals from the camshaft and crankshaft position sensors. The ECM performs feedback control and verifies target valve timing.


| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0010 |
Open or short in Camshaft Timing Oil Control Valve (OCV) circuit (3 trip detection logic) |
|
- HINT:
- The IC, built into the ECM, detects opens or shorts in the camshaft timing oil control valve circuit.
- This DTC is detected when the engine idles for approximately 15 seconds.
- The IC, built into the ECM, detects opens or shorts in the camshaft timing oil control valve circuit.
WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- Perform electronic throttle learning after replacing the ECM (Click here).
| 1. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (OCV OPERATION) |
Start the engine and warm it up.
Turn the ignition switch off.
Connect the intelligent tester to the DLC3.
Start the engine and turn the tester ON.
Select the following menu items: Powertrain / Engine and ECT / Active Test / Control the VVT System (Bank1).
Check the engine speed when operating the Camshaft Timing Oil Control Valve (OCV) using the intelligent tester.
- Result:
Specified Condition
Proceed To
Engine changes from steady idling to rough idling or engine stalling
A
No change in engine speed
B
|
|
||||
| B | |
| 2. INSPECT CAMSHAFT TIMING OIL CONTROL VALVE |
Disconnect the OCV connector.

Measure the resistance between the terminals of the camshaft timing oil control valve.
- Standard resistance:
Tester Connection
Specified Condition
1 - 2
6.9 to 7.9 Ω
Reconnect the OCV connector.
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - OCV - ECM) |
Disconnect the OCV connector.

Disconnect the ECM connector.
Remove the integration relay from the engine room relay block.
Check the resistance.
- Standard resistance (Check for open):
Tester Connection
Specified Condition
OCV- (C24-2) - OCV- (C33-61)
Below 1 Ω
OCV+ (C24-1) - Integration relay (1A-8)
Below 1 Ω
- Standard resistance (Check for short):
Tester Connection
Specified Condition
OCV- (C24-2) - Body ground
10 kΩ or higher
OCV+ (C24-1) - Body ground
10 kΩ or higher
Reconnect the OCV connector.
Reconnect the ECM connector.
Reinstall the integration relay.
|
|
||||
| OK | ||
| ||