Entry Functions do not Operate at All
Circuit diagnosis · Vehicles built from Aug 2005
DESCRIPTION
When the entry functions do not operate at all, it is possible that the certification ECU is malfunctioning or that the wire harness leading to the certification ECU is short-circuited.INSPECTION PROCEDURE
| 1. CHECK KEY CANCEL FUNCTION |
Check that the key cancel function has been set.
- OK:
- Key cancel function is set.
|
|
||||
| NG | |
| 2. CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU ASSEMBLY - BATTERY AND BODY GROUND) |
![]() ![]() |
Disconnect the D60 ECU connector.
Measure the voltage and resistance of the wire harness side connector.
- Standard voltage:
Tester Connection
Condition
Specified Condition
D60-18 (IG) - Body ground
Ignition switch off
Below 1 V
D60-18 (IG) - Body ground
Ignition switch on (IG)
10 to 14 V
D60-1 (+B1) - Body ground
Always
10 to 14 V
- Standard resistance:
Tester Connection
Specified Condition
D60-17 (E) - Body ground
Below 1 Ω
Reconnect the ECU connector.
|
|
||||
| OK | ||
| ||