Driver Side Power Window Auto Up / Down Function does not Operate with Power Window Master Switch
Circuit diagnosis · Vehicles built from Nov 2005
DESCRIPTION
- When the AUTO UP/DOWN dose not function, the power window control system may be in fail-safe mode. If the system has not been initialized after replacement of the driver door power window regulator motor, it also results in the same problem.
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. CHECK MANUAL UP / DOWN FUNCTION (DRIVER SIDE) |
Check that the manual UP/DOWN functions operate normally.
- OK:
- Manual UP/DOWN functions operate normally.
|
|
||||
| OK | |
| 2. INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY |
Remove the power window regulator master switch.

Measure the resistance.
- Standard resistance:
LHD Tester Connection
Switch Condition
Specified Condition
18 (U) - 7 (E) - 1 (AUTO)
AUTO UP
Below 1 Ω
10 (D) - 15 (B)
AUTO UP
Below 1 Ω
18 (U) - 7 (E)
UP
Below 1 Ω
10 (D) - 15 (B)
UP
Below 1 Ω
18 (U) - 10 (D) - 15 (B)
OFF
Below 1 Ω
10 (D) - 7 (E)
DOWN
Below 1 Ω
18 (U) - 15 (B)
DOWN
Below 1 Ω
1 (AUTO) - 10 (D) - 7 (E)
AUTO DOWN
Below 1 Ω
18 (U) - 15 (B)
AUTO DOWN
Below 1 Ω
RHD Tester Connection
Switch Condition
Specified Condition
9 (U) - 7 (E) - 18 (AUTO)
AUTO UP
Below 1 Ω
6 (D) - 15 (B)
AUTO UP
Below 1 Ω
9 (U) - 7 (E)
UP
Below 1 Ω
6 (D) - 15 (B)
UP
Below 1 Ω
9 (U) - 6 (D) - 15 (B)
OFF
Below 1 Ω
6 (D) - 7 (E)
DOWN
Below 1 Ω
9 (U) - 15 (B)
DOWN
Below 1 Ω
18 (AUTO) - 6 (D) - 7 (E)
AUTO DOWN
Below 1 Ω
9 (U) - 15 (B)
AUTO DOWN
Below 1 Ω
Reinstall the power window regulator master switch.
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (MASTER SWITCH - MOTOR (DRIVER SIDE)) |
Disconnect the G1 or F7 power window regulator master switch connector.


Disconnect the G8 or F8 power window regulator motor (driver side) connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance:
LHD Tester Connection
Specified Condition
G1-1 (AUTO) - G8-4 (AUTO)
Below 1 Ω
RHD Tester Connection
Specified Condition
F7-18 (AUTO) - F8-4 (AUTO)
Below 1 Ω
|
|
||||
| OK | ||
| ||