P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)
Diagnostic trouble codes · Vehicles built from Aug 2005
DESCRIPTION


The throttle pressure that is applied to the primary regulator valve (which modulates the line pressure) causes shift solenoid valve SLT, under electronic control, to precisely modulate and generate the line pressure according to the extent that the accelerator pedal is depressed or the engine power output.
This controls the line pressure and provides smooth shifting characteristics.
Upon receiving a throttle valve opening angle signal, the ECM controls the line pressure by sending a predetermined duty ratio* to the solenoid valve, modulating the line pressure and generating throttle pressure.
*: The duty ratio is the ratio of the current ON time (A) to the total of the current ON and OFF time (A + B).
Duty Ratio (%) = A / (A + B) x 100
| DTC No. |
DTC Detection Condition |
Trouble Area |
| P2716 |
Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving. (1-trip detecting logic) |
|
MONITOR DESCRIPTION
When an open or short in the linear solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault. The ECM turns on the MIL and stores the DTC.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT) |
![]() ![]() |
Disconnect the transmission wire connector from the transaxle.
Measure the resistance.
- Standard resistance:
Tester Connection
Specified Condition
3 (SLT+) - 8 (SLT-)
5.0 Ω to 5.6 Ω at 20°C (68°F)
3 (SLT+) - Body ground
10 kΩ or higher
8 (SLT-) - Body ground
10 kΩ or higher
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() ![]() |
Connect the transmission connector to the transaxle.
Disconnect the ECM connector.
Measure the resistance.
- Standard resistance:
Tester Connection
Specified Condition
76 (SLT+) - 75 (SLT-)
5.0 Ω to 5.6 Ω at 20°C (68°F)
76 (SLT+) - Body ground
10 kΩ or higher
75 (SLT-) - Body ground
10 kΩ or higher
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE SLT |
![]() ![]() |
Remove shift solenoid valve SLT.
Measure the resistance.
- Standard resistance :
Tester Connection
Specified Condition
1 - 2
5.0 Ω to 5.6 Ω at 20°C (68°F)
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
- OK:
- The solenoid makes operating sounds.
|
|
||||
| OK | ||
| ||