2005-2008 Yaris · Service Manual ENGINE

INSPECTION

Inspection · Vehicles built from Nov 2005


INSPECT GENERATOR ROTOR ASSEMBLY

A095742E01
  1. Inspect the generator rotor assembly for an open circuit.

    1. Using an ohmmeter, measure the resistance between the slip rings.

      Standard resistance:
      1.8 to 2.8 Ω at 20°C (68°F)

      If the result is not as specified, replace the generator rotor assembly.

  1. A095743E01
    Inspect the generator rotor assembly for ground.

    1. Using an ohmmeter, measure the resistance between the slip ring and generator rotor assembly.

      Standard resistance:
      10 kΩ or higher

      If the result is not as specified, replace the generator rotor assembly.

  1. A095744E01
    Check the appearance.

    1. Check that the slip rings are not rough or scored.
      If rough or scored, replace the generator rotor.

    2. Using vernier calipers, measure the slip ring diameter.

      Standard diameter:
      15.3 to 15.5 mm (0.602 to 0.610 in.)

      Minimum diameter:
      14.9 mm (0.587 in.)

      If the diameter is less than the minimum, replace the generator rotor assembly.


INSPECT STATOR SUB-ASSEMBLY GENERATOR WITH RECTIFIER

A128403E01

HINT:
For terminal positions of the stator generator, refer to the illustration.

  1. A128405E01
    Inspect the positive (+) rectifier.

    HINT:
    Inspect the positive terminal after pulling it up.


    1. Using an ohmmeter, connect the positive (+) tester probe to the positive (+) terminal and the negative (-) tester probe to each rectifier terminal.

    2. Measure the resistance between the positive (+) terminal and rectifier terminal.

      Standard resistance:
      Below 1 Ω

      If the result is not as specified, replace the stator sub-assembly generator with rectifier.

    3. Reverse the polarity of the tester probes and repeat step (1).

    4. Measure the resistance between the positive (+) terminal and rectifier terminal.

      Standard resistance:
      10 kΩ or higher

      If the result is not as specified, replace the stator sub-assembly generator with rectifier.

  1. A128404E01
    Inspect the negative (-) rectifier.

    1. Using an ohmmeter, connect the positive (+) tester probe to each negative (-) terminal and the negative (-) tester probe to each rectifier terminal.

    2. Measure the resistance between the negative (-) terminal and rectifier terminal.

      Standard resistance:
      10 kΩ or higher

      If the result is not as specified, replace the stator sub-assembly generator with rectifier.

    3. Reverse the polarity of the tester probes and repeat step (1).

    4. Measure the resistance between the negative (-) terminal and rectifier terminal.

      Standard resistance:
      Below 1 Ω

      If the result is not as specified, replace the stator sub-assembly generator with rectifier.

  1. A128406E01
    Inspect the stator for an open circuit.

    1. Using an ohmmeter, measure the resistance between the rectifier terminals.

      Standard resistance:
      Below 1 Ω

      If the result is not as specified, replace the stator sub-assembly generator with rectifier.


INSPECT BRUSH

A095749E02
  1. Using vernier calipers, measure the brush length.

    Exposed length on new brush:
    13.2 mm (0.520 in.)

    Minimum exposed length:
    6 mm (0.236 in.)

    If the exposed length is less than the minimum, replace the regulator sub-assembly generator with brush.

← DISASSEMBLY (from Nov 2005)REASSEMBLY (from Nov 2005) →