2005-2008 Yaris · Service Manual TRANSMISSION

P0905 Gate Select Position Circuit (Range / Performance)

Diagnostic trouble codes · Vehicles built from Nov 2005

Also covers:

DESCRIPTION

The select stroke sensor is mounted on the shift and select actuator, and detects the select position of shift and select lever shaft. The sensor consists of a sensor arm, magnetic yoke and 2 Hall-ICs. This sensor is a non-contact type, and uses Hall-effect elements (Hall-ICs: main and sub), in order to yield accurate signals.
When the shift and select actuator is operating in the select direction, the magnetic yoke that is coaxially positioned on the sensor arm is rotated and the magnet position changes. The hall-ICs convert the magnet position change into the voltage signals and send them to the transmission control ECU. The transmission control ECU judges the select motor operating condition (which gear shift fork shaft is selected: No. 1, No. 2 or No. 3) based on the signals from the select stroke sensor.
C112283E04
The main and sub circuits in the select stroke sensor have the same output characteristics. The sensor construction and operation of the select stroke sensor are basically the same as those of the clutch stroke sensor.
C112730E03
DTC No.
DTC Detection Conditions
Trouble Areas
P0905
Deviation between sensor signal 1 (main) and sensor signal 2 (sub) is 2.0 mm (0.078 in.) or more for 1.0 second or more
(1 trip detection logic)
  1. Select stroke sensor
  2. Open or short in select stroke sensor circuit
  3. Transmission control ECU
P0906
Select stroke sensor (main) signal voltage is 0.2 V or less for 0.5 seconds or more
(1 trip detection logic)
  1. Select stroke sensor
  2. Open or short in select stroke sensor circuit
  3. Transmission control ECU
P0906
Select stroke sensor (sub) signal voltage is 0.2 V or less for 0.5 seconds or more
(1 trip detection logic)
  1. Select stroke sensor
  2. Open or short in select stroke sensor circuit
  3. Transmission control ECU
P0907
Select stroke sensor (main) signal voltage is 4.8 V or more for 0.5 seconds or more
(1 trip detection logic)
  1. Select stroke sensor
  2. Open or short in select stroke sensor circuit
  3. Transmission control ECU
P0907
Select stroke sensor (sub) signal voltage is 4.8 V or more for 0.5 seconds or more
(1 trip detection logic)
  1. Select stroke sensor
  2. Open or short in select stroke sensor circuit
  3. Transmission control ECU

WIRING DIAGRAM

C110753E06

INSPECTION PROCEDURE

NOTICE:
In select stroke sensor replacement, perform [Initialization and Learning] (Click here) and [Synchronization Position Calibration] (Click here) after installing the sensor.
If the sensor is installed without performing [Initialization and Learning] procedure and [Synchronization Position Calibration] procedure, it may cause driving performance degradation or system component breakage.

HINT:
When only DTC P0905 is set, replace the select stroke sensor.


1. READ OUTPUT DTC
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG) and turn the tester ON.

  1. Select the following menu items: Powertrain / Multi-Mode M/T / DTC.

  1. Read DTCs.

    Result:
    Display (DTC Output)
    Proceed To
    P0905, P906 and/or P0907
    A
    Only P0905
    B



B
REPLACE SELECT STROKE SENSOR
A


2. READ VALUE USING INTELLIGENT TESTER
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG) and the tester ON.

  1. Select the following menu items: Powertrain / Multi-Mode M/T / Data List / Select Position (Current).

    Items
    [Abbreviation]
    Measurement Items: Display
    Normal Conditions
    Diagnostic Notes
    Select Position (Current)
    [Select Pos-Cur]
    Current select position:
    Min.: 0 mm, Max.: 127.998 mm
    3.0 mm (0.11 in.) to 29.0 mm (1.14 in.)
    Currently selected position value displayed (selected gear shift fork shaft position)*1

    HINT:
    *1: For the gear shift fork shaft location, refer to MULTI-MODE MANUAL TRANSAXLE UNIT (Click here).

    OK:
    The value on the tester is within the normal range.



OK
Go to step 4
NG


3. INSPECT SELECT STROKE SENSOR (MAIN)
C112722E03
  1. Remove the select stroke sensor.

  1. Measure the voltage between the terminals of the select stroke sensor connector (main).

    1. Prepare 3 dry cell batteries (1.5 V) and 2 leads for connecting the batteries and the sensor.

    2. Connect the batteries in series.

    3. Connect the positive battery terminal to sensor terminal 3, and the negative battery terminal to sensor terminal 2.

    4. Check the voltage between terminals 1 and 2.

      Standard voltage (combined dry cell battery voltage of 4.5 V):
      Sensor Angle
      Terminal (1-2) Output Voltage
      55°
      Approximately 4.05 V
      0°
      Approximately 2.25 V
      -55°
      Approximately 0.45 V

      Reference Voltage (combined dry cell battery voltage of 5.0 +- 0.3 V):
      Sensor Angle
      Terminal (1-2) Output Voltage
      55°
      Approximately 4.5 V
      0°
      Approximately 2.5 V
      -55°
      Approximately 0.5 V

      NOTICE:
      1. Do not apply more than 6 V
      2. Do not use a sensor which has been dropped.

  1. Reinstall the select stroke sensor (Click here).

  1. Perform [Initialization and Learning] (Click here) and [Synchronization Position Calibration] (Click here).



NG
REPLACE SELECT STROKE SENSOR
OK


4. INSPECT SELECT STROKE SENSOR (SUB)
C112722E04
  1. Remove the select stroke sensor.

  1. Measure the voltage between the terminals of the select stroke sensor connector (sub).

    1. Prepare 3 dry cell batteries (1.5 V) and 2 leads for connecting the batteries and the sensor.

    2. Connect the batteries in series.

    3. Connect the positive battery terminal to sensor terminal 6, and the negative battery terminal to sensor terminal 5.

    4. Check the voltage between terminals 4 and 5.

      Standard voltage (combined dry cell battery voltage of 4.5 V):
      Sensor Angle
      Terminal (4-5) Output Voltage
      55°
      Approximately 4.05 V
      0°
      Approximately 2.25 V
      -55°
      Approximately 0.45 V

      Reference Voltage (combined dry cell battery voltage of 5.0 +- 0.3 V):
      Sensor Angle
      Terminal (4-5) Output Voltage
      55°
      Approximately 4.5 V
      0°
      Approximately 2.5 V
      -55°
      Approximately 0.5 V

      NOTICE:
      1. Do not apply more than 6 V
      2. Do not use a sensor which has been dropped.

  1. Reinstall the select stroke sensor (Click here).

  1. Perform [Initialization and Learning] (Click here) and [Synchronization Position Calibration] (Click here).



NG
REPLACE SELECT STROKE SENSOR
OK


5. CHECK HARNESS AND CONNECTOR (SELECT STROKE SENSOR - TRANSMISSION CONTROL ECU)
C113919E12
  1. Disconnect the select stroke sensor connector.

  1. Disconnect the transmission control ECU connector.

  1. Check the resistance.

    Standard resistance:
    Tester Connections
    Specified Conditions
    VCL2 (A38-31) - (A45-6)
    Below 1 Ω
    VSL2 (A38-32) - (A45-4)
    Below 1 Ω
    E2L2 (A38-24) - (A45-5)
    Below 1 Ω
    VCL1 (A38-20) - (A45-3)
    Below 1 Ω
    VSL1 (A38-21) - (A45-1)
    Below 1 Ω
    E2L1 (A38-22) - (A45-2)
    Below 1 Ω
    VCL2 (A38-31) - Body ground
    10 kΩ or higher
    VSL2 (A38-32) - Body ground
    10 kΩ or higher
    E2L2 (A38-24) - Body ground
    10 kΩ or higher
    VCL1 (A38-20) - Body ground
    10 kΩ or higher
    VSL1 (A38-21) - Body ground
    10 kΩ or higher
    E2L1 (A38-22) - Body ground
    10 kΩ or higher

  1. Reconnect the select stroke sensor connector.

  1. Reconnect the transmission control ECU connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE TRANSMISSION CONTROL ECU ASSEMBLY


← P0900 Clutch Actuator Circuit (from Nov 2005)P0909 Gate Select Control Error (from Nov 2005) →