INSPECTION
Inspection · Vehicles built from Nov 2005
| INSPECT HEATED OXYGEN NO. 2 SENSOR |
![]() ![]() |
Check the resistance.
Using an ohmmeter, measure the resistance between the terminals.
- Standard resistance:
Tester Connection
Specified Condition
1 (HT1B) - 2 (+B)
11 to 16 Ω at 20°C (68°F)
1 (HT1B) - 4 (E1)
10 kΩ or higher