B1413/13 Evaporator Temperature Sensor Circuit
Diagnostic trouble codes · Vehicles built from Aug 2005
DESCRIPTION
The No.1 cooler thermistor (evaporator temperature sensor) is installed on the evaporator in the air conditioner unit to detect the temperature of the cooled air that has passed through the evaporator and to control the air conditioner. It sends signals to the air conditioning amplifier, which change in accordance with the resistance of the No.1 cooler thermistor (evaporator temperature sensor). As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases. The air conditioning amplifier applies a voltage (5 V) to the No.1 cooler thermistor (evaporator temperature sensor) and reads voltage changes as changes in the resistance of the No.1 cooler thermistor (evaporator temperature sensor). This sensor is used for frost prevention.| DTC No. |
DTC Detection Condition |
Trouble Area |
| B1413/13 |
Open or short in evaporator temperature sensor circuit |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (EVAP FIN TEMP) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch ON.
Select the item below in the Data List, and read the value displayed on the intelligent tester.
- Data List / Air Conditioner:
Item
Measurement Item / Display (Range)
Normal Condition
Diagnostic Note
Evap Fin Temp
Evaporator temperature sensor / Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.019°F)
Actual evaporator temperature is displayed
Open circuit: -29.7°C (-21.46°F)
Short circuit: 59.55°C (139.019°F)
- OK:
- The display is as specified in the normal condition column.
- Result:
Result
Proceed to
NG
A
OK (Checking from the PROBLEM SYMPTOMS TABLE)
B
OK (Checking from the DTC)
C
|
|
||||
|
|
||||
| A | |
| 2. INSPECT NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR) |
![]() ![]() |
Remove the No.1 cooler thermistor (evaporator temperature sensor).
Measure the resistance.
- Standard resistance:
Tester Connection
Condition
Specified Condition
E2-1 - E2-2
-10°C (14°F)
7.30 to 9.10 kΩ
E2-1 - E2-2
-5°C (23°F)
5.65 to 6.95 kΩ
E2-1 - E2-2
0°C (32°F)
4.40 to 5.35 kΩ
E2-1 - E2-2
5°C (41°F)
3.40 to 4.15 kΩ
E2-1 - E2-2
10°C (50°F)
2.70 to 3.25 kΩ
E2-1 - E2-2
15°C (59°F)
2.14 to 2.58 kΩ
E2-1 - E2-2
20°C (68°F)
1.71 to 2.05 kΩ
E2-1 - E2-2
25°C (77°F)
1.38 to 1.64 kΩ
E2-1 - E2-2
30°C (86°F)
1.11 to 1.32 kΩ
- NOTICE:
- Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
- HINT:
- As the temperature increases, the resistance decreases (see the graph on the left).
Reinstall the No. 1 cooler thermistor (evaporator temperature sensor) (Click here).
|
|
||||
| OK | ||
| ||