2005-2008 Yaris · Service Manual HEATER & AIR CONDITIONING SYSTEM

B1421/21 Solar Sensor Circuit (Passenger Side)

Diagnostic trouble codes · Vehicles built from Aug 2005

DESCRIPTION

The solar sensor, which is installed on the upper side of the instrument panel, detects sunlight and controls the air conditioning AUTO mode. The output voltage from the solar sensor varies in accordance with the amount of sunlight. When the sunlight increases, the output voltage increases. As the sunlight decreases, the output voltage decreases.
The air conditioning amplifier detects changes in the output voltage from the solar sensor.
DTC No.
DTC Detection Condition
Trouble Area
B1421/21
Open or short in passenger side solar sensor circuit
  1. Solar sensor
  2. Harness and connector between solar sensor and air conditioning amplifier
  3. Air conditioning amplifier

WIRING DIAGRAM

E115801E07

INSPECTION PROCEDURE


1. READ VALUE USING INTELLIGENT TESTER (SOLAR SENS-D)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG) and turn the intelligent tester main switch on.

  1. Select the item below in the Data List, and read the value displayed on the intelligent tester.

    Data List / Air Conditioner:
    Item
    Measure Item / Display
    (Range)
    Normal Condition
    Diagnostic Note
    Solar Sens-D
    Driver side solar sensor /
    Min.: 0, Max.: 255
    Driver side solar sensor voltage increases as brightness increases
    -


    Result::
    Result
    Proceed to
    NG
    A
    OK (Checking from the PROBLEM SYMPTOMS TABLE)
    B
    OK (Checking from the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER
A


2. INSPECT SOLAR SENSOR
E120978E02
  1. Remove the solar sensor.

  1. Measure the resistance.

  1. Connect the positive (+) lead from the ohmmeter to terminal 1 and the negative (-) lead to terminal 2 of the solar sensor.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    Sensor exposed to electric light
    Except ∞ Ω
    1 - 2
    Sensor covered with cloth
    ∞ Ω (No continuity)

    NOTICE:
    The connection procedure for using a digital tester such as an electrical tester is shown above. When using an analog tester, connect the positive (+) lead to terminal 2 and the negative (-) lead to terminal 1 of the solar sensor.

    HINT:
    1. As the inspection light is moved away from the sensor, the voltage decreases.
    2. Use an incandescent light for the inspection. position it about 30 cm (11.8 in.) from the solar sensor.

  1. Reinstall the solar sensor.



NG
REPLACE SOLAR SENSOR
OK


3. CHECK HARNESS AND CONNECTOR (SOLAR SENSOR - AIR CONDITIONING AMPLIFIER)
E115803E02
  1. Disconnect the D49 solar sensor connector.

  1. Disconnect the E11 air conditioning amplifier connector.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    E11-33 (TS) - D49-2 (SS-)
    Below 1 Ω
    E11-30 (S5-1) - D49-1 (SS+)
    Below 1 Ω
    E11-33 (TS) - Body ground
    1MΩ or higher
    E11-30 (S5-1) - Body ground
    1MΩ or higher

  1. Reconnect the solar sensor connector.

  1. Reconnect the air conditioning amplifier connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER