C1241
| When any of the following is detected:
- At a vehicle speed of 3 km/h (2 mph) or more, the IG1 terminal voltage is less than 9.5 V for 10 seconds or more.
- When the solenoid relay remains ON and the IG1 terminal voltage is less than 9.5 V, the relay contact is open for 0.22 seconds or more.
- With the IG1 terminal voltage 9.5 V or less, the speed sensor power supply voltage decreases for 60 seconds or more.
- While the motor relay remains ON and the IG1 terminal voltage is less than 9.5 V, the relay contact is closed for 0.22 seconds or more.
| - ECU-IG fuse
- Battery
- Charging system
- Power source circuit
- Internal power supply circuit of the skid control ECU
|