LIGHTING SYSTEM > Door Unlock Detection Switch Circuit |

| 1.READ VALUE USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Main Body / Data List.
According to the display on the intelligent tester, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| FR Door Lock Pos | Front door unlock detection switch RH signal / LOCK or UNLOCK | LOCK: Front door RH locked UNLOCK: Front door RH unlocked | - |
| FL Door Lock Pos | Front door unlock detection switch LH signal / LOCK or UNLOCK | LOCK: Front door LH locked UNLOCK: Front door LH unlocked | - |
|
| ||||
| OK | ||
| ||
| 2.INSPECT FRONT DOOR LOCK ASSEMBLY |
Inspect the front door lock assembly (Click here).
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (FRONT DOOR LOCK ASSEMBLY - MAIN BODY ECU AND BODY GROUND) |
for LHD
Disconnect the H5 front door lock assembly LH connector.
for RHD
Disconnect the G5 front door lock assembly RH connector.
Disconnect the F76 main body ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| H5-8 (LSSR) - F76-7 (LSFL) | Always | Below 1 Ω |
| H5-8 (LSSR) - Body ground | Always | 10 kΩ or higher |
| H5-7 (E) - Body ground | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| G5-7 (LSSR) - F76-18 (LSFR) | Always | Below 1 Ω |
| G5-7 (LSSR) - Body ground | Always | 10 kΩ or higher |
| G5-8 (E) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||