CAN COMMUNICATION SYSTEM (except Separate Type Yaw Rate Sensor) > ECM Communication Stop Mode |
| Detection Item | Symptom | Trouble Area |
| ECM Communication Stop Mode | Either condition is met:
|
|

| 1.CHECK FOR OPEN IN CAN BUS MAIN WIRE (ECM MAIN WIRE) |
Disconnect the A74 ECM connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A74-41 (CANH) - A74-49 (CANL) | Ignition switch off | 108 to 132 Ω |
| *a | Front view of wire harness connector (to ECM) |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT) |
Check for the ECM power source circuit (for 1NZ-FE) (Click here).
Check for the ECM power source circuit (for 2NZ-FE) (Click here).
| Result | Proceed to |
| NG | A |
| OK (for 1NZ-FE) | B |
| OK (for 2NZ-FE) | C |
|
| ||||
|
| ||||
| A | ||
| ||