DTC B1411/11 Room Temperature Sensor Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1411/11 | An open or short in the cooler thermistor (room temperature sensor) circuit. |
|

| 1.READ VALUE USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Data List.
According to the display on the intelligent tester, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Room Temperature Sensor | Room temperature sensor / Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.1°F) | Actual room temperature is displayed | - |
| Result | Proceed to |
| OK (When troubleshooting according to the DTC) | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| NG | C |
|
| ||||
|
| ||||
| A | |
| 2.CHECK FOR DTC |
Clear the DTCs (Click here).
Check for DTCs (Click here).
|
| ||||
| OK | ||
| ||
| 3.INSPECT COOLER THERMISTOR (ROOM TEMPERATURE SENSOR) |
Inspect the cooler thermistor (room temperature sensor) (Click here).
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (COOLER THERMISTOR (ROOM TEMPERATURE SENSOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY) |
Disconnect the F33 cooler thermistor (room temperature sensor) connector.
Disconnect the F42 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| F33-1 - F42-29 (TR) | Always | Below 1 Ω |
| F33-2 - F42-34 (SG-1) | Always | Below 1 Ω |
| F33-1 - Body ground | Always | 10 kΩ or higher |
| F33-2 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||