AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > PROBLEM SYMPTOMS TABLE |
| Symptom | Suspected Area | See page |
| No functions of A/C panel operate. | Air conditioning panel circuit |
Click here
|
| LIN communication system |
Click here
| |
| Air conditioning amplifier assembly |
Click here
| |
| No functions of A/C system operate. | IG power source circuit |
Click here
|
| Back-up power source circuit |
Click here
| |
| Air conditioning panel circuit |
Click here
| |
| Air conditioning amplifier assembly |
Click here
| |
| Airflow control: No blower control (Blower motor does not operate). | Blower motor circuit |
Click here
|
| Air conditioning panel circuit |
Click here
| |
| Air conditioning amplifier assembly |
Click here
| |
| Airflow control: No blower control (Blower motor does not change speed). | Blower motor circuit |
Click here
|
| Air conditioning panel circuit |
Click here
| |
| Air conditioning amplifier assembly |
Click here
| |
| Temperature control: less cool air comes out. | Refrigerant shortage check using the intelligent tester |
Click here
|
| Refrigerant pressure |
Click here
| |
| Cooler expansion valve | - | |
| Compressor with pulley assembly |
Click here
| |
| Air conditioning amplifier assembly |
Click here
| |
| Temperature control: No cool air comes out. | Refrigerant volume |
Click here
|
|
Click here
| ||
| Refrigerant pressure |
Click here
| |
| Air conditioner pressure sensor circuit |
Click here
| |
| Compressor solenoid circuit |
Click here
| |
| Air mix servo motor circuit |
Click here
| |
| Evaporator temperature sensor circuit |
Click here
| |
| Room temperature sensor circuit |
Click here
| |
| Ambient temperature sensor circuit |
Click here
| |
| Cooler expansion valve | - | |
| Air conditioning panel circuit |
Click here
| |
| Air conditioning harness circuit |
Click here
| |
| Air conditioning amplifier assembly |
Click here
| |
| ECM |
Click here
| |
| LIN communication system |
Click here
| |
| CAN communication system*1 |
Click here
| |
| CAN communication system*2 |
Click here
| |
| Temperature control: No warm air comes out. | Air mix servo motor circuit |
Click here
|
| Room temperature sensor circuit |
Click here
| |
| Evaporator temperature sensor circuit |
Click here
| |
| Ambient temperature sensor circuit |
Click here
| |
| Engine coolant temperature sensor circuit |
Click here
| |
| Air conditioning panel circuit |
Click here
| |
| Air conditioning harness circuit |
Click here
| |
| Air conditioning amplifier assembly |
Click here
| |
| ECM |
Click here
| |
| LIN communication system |
Click here
| |
| CAN communication system*1 |
Click here
| |
| CAN communication system*2 |
Click here
| |
| Temperature control: Output air is warmer or cooler than set temperature. | Refrigerant volume |
Click here
|
|
Click here
| ||
| Refrigerant pressure |
Click here
| |
| Room temperature sensor circuit |
Click here
| |
| Ambient temperature sensor circuit |
Click here
| |
| Automatic light control sensor circuit |
Click here
| |
| Air mix servo motor circuit |
Click here
| |
| Air inlet servo motor circuit |
Click here
| |
| Engine coolant temperature sensor circuit |
Click here
| |
| Radiator unit sub-assembly | - | |
| Cooler expansion valve | - | |
| Air conditioning panel circuit |
Click here
| |
| Air conditioning harness circuit |
Click here
| |
| Air conditioning amplifier assembly |
Click here
| |
| ECM |
Click here
| |
| LIN communication system |
Click here
| |
| CAN communication system*1 |
Click here
| |
| CAN communication system*2 |
Click here
| |
| Temperature control: No temperature control (Only Max. cool or Max. warm). | Air mix servo motor circuit |
Click here
|
| Room temperature sensor circuit |
Click here
| |
| Ambient temperature sensor circuit |
Click here
| |
| Evaporator temperature sensor circuit |
Click here
| |
| Automatic light control sensor circuit |
Click here
| |
| Air conditioning panel circuit |
Click here
| |
| Air conditioning harness circuit |
Click here
| |
| Air conditioning amplifier assembly |
Click here
| |
| LIN communication system |
Click here
| |
| No air inlet control. | Air inlet servo motor circuit |
Click here
|
| Air conditioning panel circuit |
Click here
| |
| Air conditioning harness circuit |
Click here
| |
| Air conditioning amplifier assembly |
Click here
| |
| No air flow mode control. | Air outlet servo motor circuit |
Click here
|
| Air conditioning harness circuit |
Click here
| |
| Air conditioning amplifier assembly |
Click here
| |
| Engine idle speed does not occur, or is continuous. | Compressor solenoid circuit |
Click here
|
| Air conditioning panel circuit |
Click here
| |
| Air conditioning amplifier assembly |
Click here
| |
| ECM |
Click here
| |
| LIN communication system |
Click here
| |
| CAN communication system*1 |
Click here
| |
| CAN communication system*2 |
Click here
| |
| Diagnostic trouble codes are not recorded. Set mode is cleared when ignition switch turned off. | Back-up power source circuit |
Click here
|
| Air conditioning amplifier assembly |
Click here
|