Home › Vehicle Interior › METER / GAUGE / DISPLAY › METER / GAUGE SYSTEM

DTC    B1507    Open in Turn Signal Circuit

DTC    B1508    Short in Turn Signal / Hazard Flasher Circuit

for Preparation Click here


DESCRIPTION

The combination meter assembly receives headlight dimmer switch information signals, and flash the turn signal lights.

DTC No.
DTC Detection
Trouble Area
B1507
When IG voltage is 9.5 V or more and the following condition detected:
  1. Open in turn signal light circuit
  1. Harness or connector
  2. Bulb
  3. Instrument panel junction block assembly
  4. Combination meter assembly
B1508
When IG voltage is 9.5 V or more and the following condition detected:
  1. Short in turn signal light circuit or hazard warning light circuit
  1. Harness or connector
  2. Bulb
  3. Instrument panel junction block assembly
  4. Combination meter assembly

WIRING DIAGRAM


E226983E02


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses and bulbs for circuits related to this system before performing the following inspection procedure.

1.INSPECT LIGHTS
  1. Inspect each turn signal light illumination.

Result 
Result
Proceed to
One side of the turn signal lights does not illuminate.
A
Front turn signal lights do not illuminate.
B
Rear turn signal lights do not illuminate.
C
Side turn signal lights do not illuminate.
D


B
Go to step 3

C
Go to step 4

D
Go to step 5
A


2.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
  1. Disconnect the F3 combination meter assembly connector.

  1. Disconnect the 3B instrument panel junction block assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    for LH 
    Tester Connection
    Condition
    Specified Condition
    F3-13 (LL) - 3B-24
    Always
    Below 1 Ω
    F3-13 (LL) - Body ground
    Always
    10 kΩ or higher
    for RH 
    Tester Connection
    Condition
    Specified Condition
    F3-7 (LR) - 3B-25
    Always
    Below 1 Ω
    F3-7 (LR) - Body ground
    Always
    10 kΩ or higher

Result 
Result
Proceed to
NG
A
OK
B


B
Go to step 6
A

REPAIR OR REPLACE HARNESS OR CONNECTOR 

3.CHECK HARNESS AND CONNECTOR (FRONT TURN SIGNAL LIGHT - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
  1. Disconnect the A7*1 or A8*2 front turn signal light connector.

    1. *1: for RH
    2. *2: for LH

  1. Disconnect the 3C instrument panel junction block assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    for LH 
    Tester Connection
    Condition
    Specified Condition
    A8-1 - 3C-28
    Always
    Below 1 Ω
    A8-2 - Body ground
    Always
    Below 1 Ω
    A8-1 - Body ground
    Always
    10 kΩ or higher
    for RH 
    Tester Connection
    Condition
    Specified Condition
    A7-1 - 3C-38
    Always
    Below 1 Ω
    A7-2 - Body ground
    Always
    Below 1 Ω
    A7-1 - Body ground
    Always
    10 kΩ or higher

    Result 
    Result
    Proceed to
    NG
    A
    OK
    B



B
Go to step 6
A

REPAIR OR REPLACE HARNESS OR CONNECTOR 

4.CHECK HARNESS AND CONNECTOR (REAR TURN SIGNAL LIGHT - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
  1. Disconnect the K38*1 or K37*2 rear turn signal light connector.

    1. *1: for RH
    2. *2: for LH

  1. Disconnect the 3D instrument panel junction block assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    for LH 
    Tester Connection
    Condition
    Specified Condition
    K37-2 - 3D-18
    Always
    Below 1 Ω
    K37-6 -Body ground
    Always
    Below 1 Ω
    K37-2 -Body ground
    Always
    10 kΩ or higher
    for RH 
    Tester Connection
    Condition
    Specified Condition
    K38-2 - 3D-5
    Always
    Below 1 Ω
    K38-6 -Body ground
    Always
    Below 1 Ω
    K38-2 -Body ground
    Always
    10 kΩ or higher

    Result 
    Result
    Proceed to
    NG
    A
    OK
    B



B
Go to step 6
A

REPAIR OR REPLACE HARNESS OR CONNECTOR 

5.CHECK HARNESS AND CONNECTOR (SIDE TURN SIGNAL LIGHT ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
  1. Disconnect the A72*1 or A73*2 side turn signal light assembly connector.

    1. *1: for RH
    2. *2: for LH

  1. Disconnect the 3C instrument panel junction block assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    for LH 
    Tester Connection
    Condition
    Specified Condition
    A73-1 (B) - 3C-29
    Always
    Below 1 Ω
    A73-2 (E) -Body ground
    Always
    Below 1 Ω
    A73-1 (B) -Body ground
    Always
    10 kΩ or higher
    for RH 
    Tester Connection
    Condition
    Specified Condition
    A72-1 (B) - 3C-37
    Always
    Below 1 Ω
    A72-2 (E) -Body ground
    Always
    Below 1 Ω
    A72-1 (B) -Body ground
    Always
    10 kΩ or higher

    Result 
    Result
    Proceed to
    NG
    A
    OK
    B



B
Go to step 6
A

REPAIR OR REPLACE HARNESS OR CONNECTOR 

6.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
  1. Remove the instrument panel junction block assembly (Click here).

  1. Remove the main body ECU (multiplex network body ECU).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3B-25 - 3C-38
    Always
    Below 1 Ω
    3B-25 - 3D-5
    Always
    Below 1 Ω
    3B-25 - 3C-37
    Always
    Below 1 Ω
    3B-24 - 3C-28
    Always
    Below 1 Ω
    3B-24 - 3D-18
    Always
    Below 1 Ω
    3B-24 - 3C-29
    Always
    Below 1 Ω



NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (Click here)
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)