| DTC |
Fail-safe operation |
B1502-H / B1502-L
|
HVAC control module controls actuators assuming that inside air temperature is 25 °C (77 °F). |
B1503
|
HVAC control module controls actuators assuming that evaporator temperature is 0 °C (32 °F). |
B1504-L
|
HVAC control module controls actuators assuming that amount of sunlight is 0 W/m2. |
B1544
|
HVAC control module controls actuators assuming the following points.
•Temperature selector is at 25 °C (77 °F) position. •Air flow switch is in “DEF” mode. •Air intake switch is in “FRE” mode. •Blower controls to “Auto”. •A/C system is ON. •Rear defogger is OFF.
|
B1550-H / B1550-L
|
B1557
|
HVAC control module controls actuators assuming that vehicle speed is 40 km/h (25 mile/h). |
B1561
|
HVAC control module controls actuators assuming that engine coolant temperature is 80 °C (176 °F). |
B1562
|
HVAC control module controls actuators assuming that outside air temperature is 20 °C (68 °F). |
B1570
|
HVAC control module controls actuators based on the data before detection of DTC. |
B1571
|