| DTC |
DTC name |
DTC detecting condition |
“AUTO” indicator |
| Display SUZUKI scan tool |
B1502-H
|
Inside Air Temperature Sensor and/or Its Circuit Malfunction |
Signal voltage of position sensor in inside air temperature sensor is higher than specified value (4.9 V) for specified time continuously. |
Blinking |
B1502-L
|
Signal voltage of position sensor in inside air temperature sensor is lower than specified value (0.1 V) for specified time continuously. |
Blinking |
B1503
|
Evaporator Temperature Sensor and/or Its Circuit Malfunction |
HVAC control module receives invalid data of evaporator temperature sensor from BCM continuously through CAN communication line. |
Blinking |
B1504-H
|
Sunload Sensor and/or Its Circuit Malfunction |
Signal voltage of position sensor in sunload sensor is higher than specified value (4.9 V) for specified time continuously. |
Off |
B1504-L
|
Signal voltage of position sensor in sunload sensor is lower than specified value (0.1 V) for specified time continuously. |
Blinking |
B1511-H
|
Temperature Control Actuator (Position Sensor) and/or Its Circuit Malfunction |
Signal voltage of position sensor in temperature control actuator is higher than specified value (4.8 V) for specified time continuously. |
Blinking |
B1511-L
|
Signal voltage of position sensor in temperature control actuator is lower than specified value (0.1 V) for specified time continuously. |
Blinking |
B1512-H
|
Air Flow Control Actuator (Position Sensor) and/or Its Circuit Malfunction |
Signal voltage of position sensor in air flow control actuator is higher than specified value (4.8 V) for specified time continuously. |
Blinking |
B1512-L
|
Signal voltage of position sensor in air flow control actuator is lower than specified value (0.1 V) for specified time continuously. |
Blinking |
B1513
|
Temperature Control Actuator and/or Its Circuit Malfunction |
Difference between target opening and actual opening is more than specified value even though temperature control actuator has operated for specified time. |
Blinking |
B1514
|
Air Flow Control Actuator and/or Its Circuit Malfunction |
Difference between target opening and actual opening is more than specified value even though air flow control actuator has operated for specified time. |
Blinking |
B1530-H
|
Air Intake Control Actuator (Position Sensor) and/or Its Circuit Malfunction |
Signal voltage of position sensor in air intake control actuator is higher than specified value (4.8 V) for specified time continuously. |
Blinking |
B1530-L
|
Signal voltage of position sensor in air intake control actuator is lower than specified value (0.1 V) for specified time continuously. |
Blinking |
B1531
|
Air Intake Control Actuator and/or Its Circuit Malfunction |
Difference between target opening and actual opening is more than specified value even though air intake control actuator has operated for specified time. |
Blinking |
B1541
|
Backup Power Supply Circuit Malfunction |
Backup power supply circuit voltage is low when ignition is “OFF”. |
Off |
B1544
|
Invalid Data between HVAC Control Module and Auto A/C Panel |
HVAC control module sent invalid signal to auto A/C panel. |
Blinking |
| HVAC control module received invalid signal from auto A/C panel. |
Blinking |
B1546
|
A/C Refrigerant Pressure Malfunction |
A/C refrigerant pressure is less than specified value, though outside air temperature is more than specified value. |
Off |
B1550-H
|
Lost Communication between HVAC Control Module and Auto A/C Panel |
Between HVAC control module and auto A/C panel, communication signal voltage is higher than specified value for specified time continuously. |
Blinking |
B1550-L
|
Between HVAC control module and auto A/C panel, communication signal voltage is lower than specified value for specified time continuously. |
Blinking |
B1557
|
Wheel Speed Sensor and/or Its Circuit Malfunction |
HVAC control module receives invalid data of vehicle speed sensor signal from ECM. |
Blinking |
B1561
|
Engine Coolant Temperature Sensor and/or Its Circuit Malfunction |
HVAC control module receives invalid data of ECT signal from ECM. |
Blinking |
B1562
|
Outside Air Temperature Sensor and/or Its Circuit Malfunction |
HVAC control module receives invalid data of outside air temperature signal from BCM continuously through CAN communication line. |
Blinking |
B1563
|
A/C Refrigerant Pressure Sensor and/or Its Circuit Malfunction |
HVAC control module receives invalid data of A/C refrigerant pressure signal from ECM. |
Off |
B1570
|
Engine Type Signal Failure |
HVAC control module receives invalid data of engine type signal from ECM. |
Off |
B1571
|
Combination Meter Spec Signal Failure |
HVAC control module receives invalid data of combination meter spec signal from combination meter. |
Off |
B1580
|
EEPROM Error |
EEPROM error has occurred in HVAC control module. |
Off |
U0073
|
Control Module Communication Bus Off |
Transmitting and receiving error of HVAC control module for specified time continuously. |
Blinking |
U0100
|
Lost Communication With ECM |
Receiving error of HVAC control module from ECM for specified time continuously. |
Blinking |
U0140
|
Lost Communication With Body Control Module |
Receiving error of HVAC control module from BCM for specified time continuously. |
Blinking |
U0155
|
Lost Communication With Instrument Panel Cluster (IPC) Control Module |
Receiving error of HVAC control module from combination meter for specified time continuously. |
Blinking |