Home › Engine / Hybrid System › 1GR-FE ENGINE CONTROL › IGNITION COIL AND SPARK PLUG › from 2014.08
RM1440E _51 Engine / Hybrid System _056124 1GR-FE ENGINE CONTROL _0273869 IGNITION COIL AND SPARK PLUG A

1GR-FE ENGINE CONTROL  IGNITION COIL AND SPARK PLUG  INSTALLATION  


PROCEDURE

Hide 19100P 1.INSTALL SPARK PLUG

a.

Install the 6 spark plugs.

Torque:
18 N*m (184 kgf*cm, 13 ft.*lbf)


Hide 19500 2.INSTALL IGNITION COIL ASSEMBLY

a.

Install the 6 ignition coil assemblies with the 6 bolts.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


b.

Connect the 6 ignition coil assembly connectors.


Hide 25702B 3.INSTALL NO. 2 EMISSION CONTROL VALVE SET (w/ Secondary Air Injection System)

Hide 17362 4.INSTALL NO. 2 AIR TUBE (w/ Secondary Air Injection System)

Hide 25701B 5.INSTALL NO. 1 EMISSION CONTROL VALVE SET (w/ Secondary Air Injection System)

Hide 17361 6.INSTALL AIR TUBE (w/ Secondary Air Injection System)

Hide 7.INSTALL AIR CLEANER CAP AND HOSE

a.
U147608E04
1.198,2 2.698,2.063 1.5,0.063 2.938,2.625 3.219,2.625 false 1.844,2.771 2.25,2.396 2.25,2.396 2.375,2.396 false 0.052,2.448 0.313,2.656 0.26,0.208 10 false 90° 2.302,2.792 2.563,3 0.26,0.208 10 false 90° 1.75,2.26 2.01,2.469 0.26,0.208 10 false 60° 0.802,2.073 0.969,2.24 0.167,0.167 10 false *a 1.292,2.49 1.458,2.656 0.167,0.167 10 false *b 1.427,2.75 1.594,2.917 0.167,0.167 10 false *c 3.25,2.521 3.427,2.698 0.177,0.177 10 false *d 2.25,1.781 2.375,1.938 0.125,0.156 10 false A 1.938,1.354 2.063,1.51 0.125,0.156 10 false B 0.865,3.177 0.99,3.333 0.125,0.156 10 false A 1.792,3.188 1.917,3.344 0.125,0.156 10 false B 1.74,2.073 1.906,2.24 0.167,0.167 10 false *a 2.417,2.323 2.583,2.49 0.167,0.167 10 false *e

Install the air cleaner cap and hose.

Text in Illustration
*a Upper
*b Front
*c RH
*d Align cutout portion of hose with protrusion of throttle
*e Paint Mark

i.

Install the air cleaner cap and hose with the bolt and fasten the 4 hook clamps.

Torque:
5.0 N*m (51 kgf*cm, 44 in.*lbf)


ii.

Tighten the clamp.

Torque:
5.0 N*m (51 kgf*cm, 44 in.*lbf)


iii.

Attach the 4 clamps and connect the ventilation hose, vacuum hose and mass air flow meter connector.

HINT:

The direction of the hose clamp is indicated in the illustration.