The fuel pump circuit consists of the ECM, fuel pump and fuel pump ECU (which operates the fuel pump). Based on the engine output, the ECM determines the fuel pump speed. The speed is then converted to a duty signal and sent to the fuel pump ECU. Based on the signal sent from the ECM, the fuel pump ECU adjusts the fuel pump operation speed among 3 settings.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
This troubleshooting procedure is based on the premise that the engine can be started. If the engine cannot be started, proceed to Problem Symptoms Table (See page Engine / Hybrid System>1GR-FE ENGINE CONTROL>SFI SYSTEM>PROBLEM SYMPTOMS TABLE).
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Fuel Pump / Speed.
Check whether operating sounds can be heard while operating the fuel pump using the intelligent tester.
Operating sounds can be heard from fuel pump.
OK
NG
Inspect the circuit opening relay (C/OPN) (See page Engine / Hybrid System>1GR-FE ENGINE CONTROL>RELAY>ON-VEHICLE INSPECTION).
OK
NG
Remove the circuit opening relay (C/OPN) from the engine room relay block.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| Circuit opening relay (C/OPN) terminal 2 - Body ground | Ignition switch ON | 11 to 14 V |
| Circuit opening relay (C/OPN) terminal 5 - Body ground | Ignition switch ON | 11 to 14 V |
| *1 | Engine Room Relay Block |
| *2 | Circuit Opening Relay (C/OPN) |
OK
NG
Remove the circuit opening relay (C/OPN) from the engine room relay block.
Disconnect the ECM connector.
Disconnect the fuel pump ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Circuit opening relay (C/OPN) terminal 1 - F50-8 (FC) | Always | Below 1 Ω |
| Circuit opening relay (C/OPN) terminal 3 - Q8-4 (+B) | Always | Below 1 Ω |
| Circuit opening relay (C/OPN) terminal 1 or F50-8 (FC) - Body ground | Always | 10 kΩ or higher |
| Circuit opening relay (C/OPN) terminal 3 or Q8-4 (+B) - Body ground | Always | 10 kΩ or higher |
OK
NG
Disconnect the fuel pump connector.
Disconnect the fuel pump ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Q5-4 (B2) - Q9-1 (FP) | Always | Below 1 Ω |
| Q5-5 (E2) - Q9-2 (FP-) | Always | Below 1 Ω |
| Q5-4 (B2) or Q9-1 (FP) - Body ground | Always | 10 kΩ or higher |
| Q5-5 (E2) or Q9-2 (FP-) - Body ground | Always | 10 kΩ or higher |
OK
NG
Inspect the fuel pump (See page Engine / Hybrid System>1GR-FE FUEL>FUEL PUMP>INSPECTION).
OK
NG
Disconnect the fuel pump ECU connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Q8-1 (FPC) - F51-3 (FPC) | Always | Below 1 Ω |
| Q8-2 (DI) - F50-26 (DI) | Always | Below 1 Ω |
| Q8-3 (E) - Body ground | Always | Below 1 Ω |
| Q8-1 (FPC) or F51-3 (FPC) - Body ground | Always | 10 kΩ or higher |
| Q8-2 (DI) or F50-26 (DI) - Body ground | Always | 10 kΩ or higher |
OK
NG
Replace the fuel pump ECU (see page Engine / Hybrid System>1GR-FE FUEL>FUEL PUMP ECU>REMOVAL).
NEXT
Check the fuel pump operation.
Malfunction has been repaired successfully.
OK
NG
Remove the circuit opening relay (C/OPN) from the engine room relay block.
Remove the No. 1 integration relay from the engine room relay block.
Disconnect the No. 1 integration relay connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Circuit opening relay (C/OPN) terminal 2 - 1C-4 | Always | Below 1 Ω |
| Circuit opening relay (C/OPN) terminal 5 - 1D-4 | Always | Below 1 Ω |
| Circuit opening relay (C/OPN) terminal 2 or 1C-4 - Body ground | Always | 10 kΩ or higher |
| Circuit opening relay (C/OPN) terminal 5 or 1D-4 - Body ground | Always | 10 kΩ or higher |
OK
NG