When the ignition switch is turned to ON, the battery voltage is applied to terminal IGSW of the ECM. The output signal from the MREL terminal of the ECM causes a current to flow to the coil of the No. 1 integration relay (EFI MAIN), closing the contacts and supplying power to both terminal +B and +B2 of the ECM.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Remove the No. 1 integration relay from the engine room relay block.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1E-1 - Body ground | Always | 11 to 14 V |
| *1 | Engine Room Relay Block |
| *a | Front view of wire harness connector
(to No. 1 Integration Relay) |
Reinstall the No. 1 integration relay.
OK
NG
Inspect the No. 1 integration relay (EFI MAIN) (See page Engine / Hybrid System>1GR-FE ENGINE CONTROL>RELAY>ON-VEHICLE INSPECTION).
OK
NG
Check the harness and connectors between the No. 1 integration relay and ECM.
Remove the No. 1 integration relay from the engine room relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F51-9 (MREL) - 1D-2 | Always | Below 1 Ω |
| F51-22 (+B) - 1D-4 | Always | |
| F51-23 (+B2) - 1D-4 | Always |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F51-9 (MREL) or 1D-2 - Body ground | Always | 10 kΩ or higher |
| F51-22 (+B) or 1D-4 - Body ground | Always | |
| F51-23 (+B2) or 1D-4 - Body ground | Always |
Check the harness and connectors between the No. 1 integration relay and body ground.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1D-3 - Body ground | Always | Below 1 Ω |
Reinstall the No. 1 integration relay.
Reconnect the ECM connector.
OK
NG
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B38-12 (E1) - Body ground | Always | Below 1 Ω |
Reconnect the ECM connector.
OK
NG
Disconnect the ECM connectors.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| F50-21 (IGSW) - B38-12 (E1) | Ignition switch ON | 11 to 14 V |
| *a | Rear view of wire harness connector
(to ECM) |
Reconnect the ECM connectors.
OK
NG
Inspect the No. 1 integration relay (IG2) (See page Engine / Hybrid System>1GR-FE ENGINE CONTROL>RELAY>ON-VEHICLE INSPECTION).
OK
NG
Remove the No. 1 integration relay (IG2) from the engine room relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1C-4 - F50-21 (IGSW) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1C-4 or F50-21 (IGSW) - Body ground | Always | 10 kΩ or higher |
Reinstall the No. 1 integration relay (IG2).
Reconnect the ECM connector.
| Result | Proceed to |
|---|---|
| Out of normal range | A |
| Within normal range | B |
A
B
Remove the No. 1 integration relay (IG2) from the engine room relay block.
Disconnect the ignition switch connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1C-1 - F15-6 (IG2) | Always | Below 1 Ω |
| 1C-3 - Body ground | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F15-6 (IG2) - Body ground | Always | 10 kΩ or higher |
Reinstall the No. 1 integration relay (IG2).
Reconnect the ignition switch connector.
OK
NG
Inspect the ignition switch (See page Engine / Hybrid System>1GR-FE STARTING>IGNITION SWITCH>INSPECTION).
OK
NG