Home › Drivetrain › A750E AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM
RM1440E _52 Drivetrain _056133 A750E AUTOMATIC TRANSMISSION / TRANSAXLE _0273938 AUTOMATIC TRANSMISSION SYSTEM C

A750E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM  P0776  Pressure Control Solenoid "B" Performance (Shift Solenoid Valve SL2)  


DESCRIPTION

The ECM uses signals from the output shaft speed sensor and input speed sensor to detect the actual gear position (1st, 2nd, 3rd, 4th or 5th gear).

Then the ECM compares the actual gear with the shift schedule in the ECM memory to detect mechanical problems of the shift solenoid valves, valve body or automatic transmission (clutch, brake, gear, etc.).

DTC Code DTC Detection Condition Trouble Area
P0776 Gear required by the ECM does not match the actual gear when driving (1-trip detection logic).
·

Shift solenoid valve SL2 remains open

·

Shift solenoid valve SLT remains open or closed

·

Valve body is blocked

·

Automatic transmission (clutch, brake, gear, etc.)



MONITOR DESCRIPTION

This DTC indicates a stuck ON malfunction of the shift solenoid valve SL2.

The ECM commands gear shifts by turning the shift solenoid valves ON/OFF. When the gear position commanded by the ECM and the actual gear position are not the same, the ECM illuminates the MIL and stores the DTC.

CAUTION / NOTICE / HINT

ACTIVE TEST


HINT:

Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Warm up the engine.


b.

Turn the ignition switch off.


c.

Connect the intelligent tester to the DLC3.


d.

Turn the ignition switch to ON.


e.

Turn the intelligent tester on.


f.

Enter the following menus: Powertrain / Engine and ECT / Active Test.


g.

According to the display on the tester, perform the Active Test.

HINT:

While driving, the shift position can be forcibly changed with the intelligent tester.

Comparing the shift position commanded by the Active Test with the actual shift position enables you to confirm the problem (See page Drivetrain>A750E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>FAIL-SAFE CHART).


Engine and ECT
Tester Display Test Part Control Range Diagnostic Note
Control the Shift Position Operate shift solenoid valve and set each shift position
·

Press "→" button: Shift up

·

Press "←" button: Shift down


Possible to check operation of the shift solenoid valves.
[Vehicle Condition]
50 km/h (31 mph) or less.

HINT:
·

This test can be conducted when the vehicle speed is 50 km/h (31 mph) or less.

·

The 4th to 5th up-shift must be performed with the accelerator pedal released.

·

The 5th to 4th down-shift must be performed with the accelerator pedal released.

·

Do not operate the accelerator pedal for at least 2 seconds after shifting and do not shift successively.

·

The shift position commanded by the ECM is shown in the Data List display on the tester.

·

The shift solenoid valve SL2 turns ON/OFF normally when the shift lever is in D.

ECM gear shift command 1st 2nd 3rd 4th 5th
Shift solenoid valve SL2 ON ON ON ON OFF





PROCEDURE

1.CHECK DTC OUTPUT (IN ADDITION TO DTC P0776)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the intelligent tester on.


d.

Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.


e.

Read the DTCs using the tester.

Result
Result Proceed to
Only P0776 is output A
P0776 and other DTCs are output B

HINT:

If any other codes besides P0776 are output, perform troubleshooting for those DTCs first.




A

2.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (SHIFT SOLENOID VALVE SLT)

B

2.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (SHIFT SOLENOID VALVE SLT)

OK

3.INSPECT SHIFT SOLENOID VALVE SL2

NG

3.INSPECT SHIFT SOLENOID VALVE SL2
a.

Remove shift solenoid valve SL2.


C197715E10
1.76,1 2.208,0.417 false 1.5,1 1.042,0.417 false 1.76,2.99 2.208,2.396 false 1.479,2.969 1.021,2.375 false 0.052,0.01 0.365,0.208 0.313,0.198 10 false *a 2.24,0.198 2.406,0.396 0.167,0.198 10 false 1 0.917,0.198 1.083,0.396 0.167,0.198 10 false 2 2.24,2.188 2.406,2.385 0.167,0.198 10 false 1 0.917,2.188 1.083,2.385 0.167,0.198 10 false 2 1.927,3.927 2.156,4.125 0.229,0.198 10 false (+) 1.167,3.927 1.396,4.125 0.229,0.198 10 false (-)

b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



c.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 1

·

Battery negative (-) → Terminal 2


Valve moves and makes operating noise



Text in Illustration
*a Component without harness connected
(Shift Solenoid Valve SL2)


OK

4.INSPECT TRANSMISSION VALVE BODY ASSEMBLY

NG

4.INSPECT TRANSMISSION VALVE BODY ASSEMBLY

OK

REPAIR OR REPLACE AUTOMATIC TRANSMISSION ASSEMBLY

NG

REPAIR OR REPLACE TRANSMISSION VALVE BODY ASSEMBLY