DTC P0037 Oxygen Sensor Heater Control Circuit Low (Bank 1 Sensor 2) |
DTC P0038 Oxygen Sensor Heater Control Circuit High (Bank 1 Sensor 2) |
DTC P0057 Oxygen Sensor Heater Control Circuit Low (Bank 2 Sensor 2) |
DTC P0058 Oxygen Sensor Heater Control Circuit High (Bank 2 Sensor 2) |
DTC P0141 Oxygen Sensor Heater Circuit Malfunction (Bank 1 Sensor 2) |
DTC P0161 Oxygen Sensor Heater Circuit Malfunction (Bank 2 Sensor 2) |
DTC P102D O2 Sensor Heater Circuit Performance Bank 1 Sensor 2 Stuck ON |
DTC P105D O2 Sensor Heater Circuit Performance Bank 2 Sensor 2 Stuck ON |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0037 P0057 | The heater current is below the specified value while the heater is operating (1 trip detection logic). |
|
| P0038 P0058 | The heater current is higher than the specified value while the heater is operating (1 trip detection logic). |
|
| P0141 P0161 | Cumulative heater resistance correction value exceeds the threshold (2 trip detection logic). |
|
| P102D P105D | The heater current is higher than the specified value while the heater is not operating (1 trip detection logic). | ECM |
| Related DTCs | P0037: Heated oxygen sensor heater (bank 1) range check (Low electrical current) P0038: Heated oxygen sensor heater (bank 1) range check (High electrical current) P0057: Heated oxygen sensor heater (bank 2) range check (Low electrical current) P0058: Heated oxygen sensor heater (bank 2) range check (High electrical current) P0141: Heated oxygen sensor heater performance (bank 1) P0161: Heated oxygen sensor heater performance (bank 2) P102D: Heated oxygen sensor heater stuck ON (for Bank 1 Sensor 2) P105D: Heated oxygen sensor heater stuck ON (for Bank 2 Sensor 2) |
| Required Sensors/Components (Main) | Heated oxygen sensor heater |
| Required Sensors/Components (Related) | - |
| Frequency of Operation | Continuous: P0037, P0038, P0057, P0058 P102D and P105D Once per driving cycle: P0141 and P0161 |
| Duration | 0.5 seconds: P0037 and P0057 Within 3 seconds: P0038 and P0058 10 seconds: P0141 and P0161 0.5 seconds: P102D and P105D |
| MIL Operation | Immediate: P0037, P0038, P0057, P0058, P102D and P105D 2 driving cycles: P0141 and P0161 |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not stored | P0032, P0052 (Air fuel ratio sensor heater) P0038, P0058 (Rear oxygen sensor heater) |
| Battery voltage | 10.5 V or higher |
| Engine | Running |
| Starter | OFF |
| Catalyst active A/F control | Not operating |
| Time after heater ON | 10 seconds or more |
| Learned heater OFF current operation | Complete |
| Heater OFF current learned value | Acquired |
| Monitor runs whenever following DTCs not stored | P0031, P0032, P0051, P0052 (Air fuel ratio sensor heater) P0038, P0058 (Rear oxygen sensor heater) |
| Battery voltage | 10.5 V or higher |
| Engine | Running |
| Starter | OFF |
| Catalyst active A/F control | Not operating |
| Time after heater ON | 10 seconds or more |
| Learned heater OFF current operation | Complete |
| Heated oxygen sensor heater OFF current | Higher than 3.5 A |
| Hybrid IC high current limiter monitor | Fail |
| Monitor runs whenever following DTCs not stored | None |
| Battery voltage | 10.5 V or higher |
| Engine | Running |
| Starter | OFF |
| Catalyst active A/F control | Not operating |
| Time after heater ON | 10 seconds or more |
| Learned heater OFF current operation | Complete |
| Monitor runs whenever following DTCs not stored | P0031, P0032, P0051, P0052 (Air fuel ratio sensor heater) P0037, P0038, P0057, P0058 (Rear oxygen sensor heater) |
| Battery voltage | 10.5 V or higher |
| Fuel cut | OFF |
| Time after fuel cut ON to OFF | 30 seconds or more |
| Accumulated heater ON time | 100 seconds or more |
| Learned heater OFF current operation | Complete |
| Monitor runs whenever following DTCs not stored | None |
| Duration that rear heated oxygen sensor impedance is less than 15 kΩ | 2 seconds or more |
| Monitor runs whenever following DTCs not stored | P0031, P0032, P0051, P0052 (Air fuel ratio sensor heater) P0037, P0038, P0057, P0058 (Rear oxygen sensor heater) |
| Battery voltage | 10.5 V or higher |
| Engine | Running |
| Starter | OFF |
| Catalyst active A/F control | Not operating |
| Time after heater ON | 10 seconds or more |
| Learned heater OFF current operation | Complete |
| Hybrid IC high current limiter port | Fail |
| Heater current - Learned heater OFF current | 0.3 A or less |
| Heated oxygen sensor heater ON current | 1 A or less |
| Hybrid IC high current limiter monitor | Fail |
| Heated oxygen sensor heater output | ON |
| Accumulated heater resistance | Varies with sensor element temperature (Example: Higher than 23 Ω) |
| Heated oxygen sensor heater ON current | Higher than 1 A |
| Heated oxygen sensor heater current | 0.4 to 1 A (when engine idling, heated oxygen sensor warmed up and battery voltage 11 to 14 V) |

| Tester Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|
| 1.INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE) |
Inspect the heated oxygen sensor .
|
| ||||
| OK | |
| 2.CHECK TERMINAL VOLTAGE (+B OF HEATED OXYGEN SENSOR) |
![]() |
Disconnect the heated oxygen sensor connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| B29-2 (+B) - Body ground | 11 to 14 V |
| B30-2 (+B) - Body ground | 11 to 14 V |
| *a | Front view of wire harness connector (to Heated Oxygen Sensor Bank 1) |
| *b | Front view of wire harness connector (to Heated Oxygen Sensor Bank 2) |
Reconnect the heated oxygen sensor connector.
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM) |
Disconnect the heated oxygen sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B29-1 (HT1B) - B39-12 (HT1B) | Always | Below 1 Ω |
| B30-1 (HT2B) - B39-13 (HT2B) | Always | Below 1 Ω |
| B29-1 (HT1B) or B39-12 (HT1B) - Body ground | Always | 10 kΩ or higher |
| B30-1 (HT2B) or B39-13 (HT2B) - Body ground | Always | 10 kΩ or higher |
Reconnect the heated oxygen sensor connector.
Reconnect the ECM connector.
|
| ||||
| OK | |
| 4.CHECK WHETHER DTC OUTPUT RECURS |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream ON.
Clear DTCs (Click here).
Start the engine.
Drive the vehicle in accordance with the driving pattern described in the Confirmation Driving Pattern.
Read the output pending DTCs using the Techstream.
| Result | Proceed to |
| No pending DTC is output | A |
| Pending DTC P0037, P0038, P0057, P0058, P0141, P0161, P102D and/or P105D is output | B |
|
| ||||
| A | ||
| ||
| 5.INSPECT NO. 1 INTEGRATION RELAY (EFI MAIN) |
Inspect the No. 1 integration relay (EFI MAIN) .
|
| ||||
| OK | |
| 6.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - NO. 1 INTEGRATION RELAY (EFI MAIN)) |
Disconnect the heated oxygen sensor connector.
Remove the No. 1 integration relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B29-2 (+B) - 1D-4 | Always | Below 1 Ω |
| B30-2 (+B) - 1D-4 | Always | Below 1 Ω |
| B29-2 (+B) or 1D-4 - Body ground | Always | 10 kΩ or higher |
| B30-2 (+B) or 1D-4 - Body ground | Always | 10 kΩ or higher |
Reconnect the heated oxygen sensor connector.
Reinstall the No. 1 integration relay.
|
| ||||
| OK | ||
| ||