DTC B278A Short to GND in Immobiliser System Power Source Circuit |
| DTC Code | DTC Detection Condition | Trouble Area |
| B278A | The engine switch power source supply line is open or shorted. |
|

| 1.CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU - ENGINE SWITCH) |
Disconnect the F79 ECU connector.
Disconnect the F71 switch connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| F79-28 (VC5) - F71-14 (VC5) | Always | Below 1 Ω |
| F79-36 (AGND) - F71-8 (AGND) | ||
| F79-28 (VC5) or F71-14 (VC5) - Body ground | Always | 10 kΩ or higher |
| F79-36 (AGND) or F71-8 (AGND) - Body ground |
|
| ||||
| OK | |
| 2.CHECK CERTIFICATION ECU |
![]() |
Using an oscilloscope, check the waveform.
| Item | Content |
| Tester Connection | F71-14 (VC5) - F71-8 (AGND) |
| Tool Setting | 2 V/DIV., 20 ms./DIV. |
| Condition | Engine switch off, key not in cabin and 30 seconds or less after engine switch pushed |
| *a | Component with harness connected (Engine Switch) |
|
| ||||
| OK | ||
| ||